8.

Place the upper housing plate so that the two
notched areas align with the two studs on the motor
coupler. Aligning the six screw holes of the upper
housing plate onto the motor hub.  Firmly attach the
upper housing to the motor hub/upper housing plate
by using the six #8-32 x 1/2” pan head screws with
lockwashers (supplied) (Figure 4).   

9.

Remove the hanger ball by loosening the setscrew
in the hanger ball until the ball falls freely down the
downrod (Figure 5). Remove the pin from the
downrod, then remove the hanger ball. Retain the
pin and hanger ball for reinstallation in Step 12.

10.

Separate, untwist and unkink the three 80” motor
leads. Route the motor lead wires through the
downrod. Align the clevis pin holes in the downrod
with the holes in the motor coupler. Install the clevis
pin and secure with the hairpin clip (Figure 6). The
clevis pin must go through the holes in the motor
coupler and the holes in the downrod. Be sure to
push the straight leg of the hairpin clip through the
hole near the end of the clevis pin until the curved
portion of the hairpin clip snaps around the clevis
pin. The hairpin clip must be properly installed to
prevent the clevis pin from working loose. Pull on
the downrod to make sure the clevis pin is properly
installed.

11.

While pulling up on the downrod, reinstall and
tighten the two setscrews (previously removed in
Step 6) in the motor coupler (Figure 6).

12.

Make sure the grommet is properly installed in the
coupler cover, then slide the coupler cover on the
downrod until it rests on the motor housing. Place
the ceiling cover over the downrod. Be sure that the
ceiling cover and the coupler cover are both
oriented correctly (Figure 7).

13.

Reinstall the hanger ball (Figure 7) on the downrod
as follows. Route the three 80” motor leads through
the hanger ball. Position the pin through the two
holes in the downrod and align the hanger ball so
the pin is captured in the groove in the top of the
hanger ball. Pull the hanger ball up tight against the
pin and securely tighten the setscrew in the hanger
ball. A loose setscrew could create fan wobble.

6

ETL Model No.: CF766

COUPLER COVER

CEILING 
COVER

PIN

HANGER 
BALL

GROMMET

EU

P

T H I S   S I D E   U P

T H I S   S I D E   U P

DOWNROD

Figure 7

It is critical that the pin in the hanger ball is properly
installed and the setscrew securely tightened. Failure
to verify that the pin and setscrew are properly
installed could result in the fan falling.

WARNING

!

HAIRPIN CLIP

MOTOR COUPLER

DOWNROD

CLEVIS 
PIN

HAIRPIN
CLIP

MOTOR
COUPLER

SETSCREW

CLEVIS PIN

UP

T H I S   S I D E   U P

T H I S   S I D E   U P

REINSTALL 
SETSCREW (2)

Figure 6

T H I S   S I D E   U P

#8-32 x 1/2" PAN 
HEAD SCREW  WITH 
LOCKWASHER (6)

REINSTALL 
SETSCREW (2)

MOTOR COUPLER

MOTOR 
COUPLER 
STUD (2)

UPPER HOUSING 
PLATE

Figure 4

DOWNROD

PIN

SETSCREW

HANGER BALL

Figure 5

It is critical that the clevis pin in the motor coupler is
properly installed and the setscrews securely
tightened. Failure to verify that the pin and setscrews
are properly installed (as shown in Figure 6) could
result in the fan falling.

WARNING

!

3. Ceiling Fan Assembly

(continued)

Содержание AVENUE CF766ORB

Страница 1: ...shed Steel with Chocolate Blades CF766ORB00 Oil Rubbed Bronze with Oil Rubbed Bronze Blades CF766SBS00 Brushed Steel with Brushed Steel Blades Net Weight 28 9 Lbs Questions problems missing parts Before returning to the store call Emerson Electric Customer Service 8 a m 6 p m Eastern Monday Friday 1 800 654 3545 www emersonfans com CF766SW00 Satin White with Satin White Blades CF766VS00 Vintage St...

Страница 2: ...l wiring have your fan installed by a licensed electrician WARNING To reduce the risk of electrical shock this fan must be installed with an isolating wall control switch NOTE This fan is suitable for use with solid state speed controls WARNING This product is designed to use only those parts supplied with this product and or any accessories designated specifically for use this product by Emerson ...

Страница 3: ...eding 2 Remove the fan assembly from the protective plastic bag Place the fan assembly into the upper foam pad with the top of the motor facing up The upper foam pad serves as a holder for the fan during the first stages of assembly M L H I J K N A B C D THIS SIDE UP THIS SIDE UP THIS SIDE UP E F G OFF ON PACKAGE CONTENTS 1 4 3 7 8 12 2 6 5 9 11 10 HARDWARE CONTENTS Part Description Quantity A Fan...

Страница 4: ...Electrical Requirements Your new ceiling fan will require a grounded electrical supply line of 120 volts AC 60 Hz 15 amp circuit To reduce the risk of fire electric shock or personal injury mount fan to outlet box marked Acceptable for Fan Support of 22 7 kg 50 lbs or less and use screws supplied with outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for f...

Страница 5: ...at this procedure for the remaining two blades assemblies 6 Remove the two setscrews from the top of the motor coupler Figure 3 Retain the setscrews for future use 7 Position the upper housing onto the upper housing plate aligning the two notched areas the six screw holes and the reverse switch hole Figure 3 U P THIS SIDE UP THIS SIDE UP UPPER HOUSING REVERSE SWITCH MOTOR COUPLER NOTCHED AREA 2 SE...

Страница 6: ...is properly installed in the coupler cover then slide the coupler cover on the downrod until it rests on the motor housing Place the ceiling cover over the downrod Be sure that the ceiling cover and the coupler cover are both oriented correctly Figure 7 13 Reinstall the hanger ball Figure 7 on the downrod as follows Route the three 80 motor leads through the hanger ball Position the pin through th...

Страница 7: ...wire connector of the motor connector Make sure the connector latches are closed properly 19 Carefully tuck all wires and splices into the light kit assembly NOTE Do not pinch wires between the lower housing and the switch adapter LOWER HOUSING LIGHT KIT ASSEMBLY LIGHT KIT ASSEMBLY SCREW 3 Figure 10 7 emersonfans com Please contact 1 800 654 3545 for further assistance ETL Model No CF766 20 Remove...

Страница 8: ...ersonal injury mount fan to outlet box marked Acceptable for Fan Support of 22 7 kg 50 lbs or less and use screws supplied with outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt WARNING The fan must be hung with at least 7 of clearance from floor to blades Figure 11 WAR...

Страница 9: ...round wire 2 Refer to Figure 14 and 15 and connect the receiver wires to the supply wires and the fan motor wires as follows a Securely connect the green grounding wires from the hanger ball and the hanger bracket to the supply grounding conductor this may be a bare wire or a wire with green insulation b Securely connect the supply white neutral wire to the receiver white AC IN N wire c Securely c...

Страница 10: ...g the three flat areas on the top edge of the glass with the three light kit tips on the light kit assembly and turn the glass bowl clockwise until it stops Figure 17 NOTE It is advisable to periodically check that the glass is seated fully clockwise in the light kit assembly Over lamping the fan will result in the light bulbs being automatically shut off Use only 60 watt maximum candelabra light ...

Страница 11: ... Before starting disconnect power to the circuit at the fuse box or circuit breaker panel 7 Remove the faceplate and screws from the existing wall switch Pull switch out from wall outlet box 8 Disconnect wire from existing fan wall switch Figure 19 Setting Operating Frequency of Wall Control Your wall control has code switches which must be set in one of 32 possible code combinations The five leve...

Страница 12: ...TO 120VAC SOURCE G R O UND OFF ON HIGH TO LOW BUTTONS ON OFF SWITCH O OFF ON LIGHT BUTTON FAN BUTTON POWER INDICATOR LIGHT OFF ON Figure 21 Figure 22 Operation of Your Reverse Switch IMPORTANT Fan installation must be completed including the installation of the fan blades before testing of the controls 17 Restore electrical power to the outlet box by turning the electricity on at the main fuse box...

Страница 13: ...TL Model No CF766 Ceiling fan performance and energy savings rely heavily on the proper installation and use of the ceiling fan Here are a few tips to ensure quality and product performance Choosing the Appropriate Mounting Location Ceiling fans should be installed or mounted in the middle of the room and at least 7 feet above the floor and 18 inches from the walls If ceiling height allows install...

Страница 14: ...m Solid State speed control variable speed controls If Solid State Control is used and motor noise results choose an alternative control method 5 Screws holding blades to flanges are loose 5 Tighten screws securely 3 Fan wobbles 1 Setscrews in motor coupler are not 1 Raise coupler cover and tighten setscrews securely excessively tightened securely 2 Setscrew in the hangerball downrod assembly is 2...

Страница 15: ...Notes 15 emersonfans com Please contact 1 800 654 3545 for further assistance ETL Model No CF766 ...

Страница 16: ...16 ETL Model No CF766 12 Repair Parts 1 5 2 3 18 17 6 7 19 25 4 20 23 24 16 OFF ON 8 9 22 11 15 10 THIS SIDE UP 14 THIS SIDE UP 12 21 13 13 ...

Страница 17: ... Stud 2 6 Lockwasher 2 7 Knurled Knob 2 8 Pin Clevis 9 Clip Hairpin 10 Screw Pan Head with Lockwasher 8 32 x 1 2 7 11 Screw Pan Head with Lockwasher 1 4 20 x 1 2 7 12 Screw Washer Head 10 32 x 1 4 10 13 Screw Pan Head 8 32 x 3 8 1 14 Nut Decorative 10 15 Upper Housing Plate 16 Blade Balance Kit 17 Ceiling Canopy 764348 BS 764348 ORB 764348 BS 764348 SW 764348 VS 18 Coupler Cover 764360 BS 764360 O...

Страница 18: ...18 ETL Model No CF766 Notes ...

Страница 19: ...s limited warranty You can return your Emerson Ceiling Fan to your place of purchase or you can call Emerson Customer Service at 1 800 237 6511 to obtain a return authorization and service identification tag In order for us to confirm that your Emerson Ceiling Fan is still under warranty please retain your receipt or other proof of purchase and have that information readily available when returnin...

Страница 20: ...Service 8 a m 6 p m Eastern Monday Friday 1 800 654 3545 www emersonfans com Retain this manual for future use Air Comfort Products DIVISION OF EMERSON ELECTRIC CO 8100 W Florissant St Louis MO 63136 Part No F40BP74710001 Form No BP7471 1 Revision 131015 ETL Model No CF766 Printed in China 10 13 ...

Отзывы: