Sentronic

PLUS

INSTALLATION 

MANUAL

ELECTRONIC

PRESSURE REGULATOR

Installation and Operating Instructions

1. 

Before putting into operation carefully check all electrical connections and the supply voltage (24 VDC ±10 %). 

Overload can destroy the electronics. Recommended pre-fuse T2.0 A.

2. 

The electrical connection is made with a round connector M12x1. The connector must meet the requirements of 

DIN 60079-15.

 

WARNING: 

Do not disconnect the plug while under voltage!

 

When disconnected from power, use supplied protection cover to ensure IP protection.

3. 

Use unshielded or shielded cables for the electrical connection of the valve. The shield, connector and control 

cabinet must be EMC compliant. The valve body must be electrically connected to ground (PE, machine ground). 

Do not run control cables parallel to high-voltage lines or servo-motor control cables.

4. 

The cable length between the IO-Link master and the valve must not exceed 20m.

5. 

Make sure that the valve is under pressure when a setpoint signal is applied to the valve (applying a setpoint 

signal with no pressure on the valve will cause it to overheat).

6. 

The valve is factory adjusted.

7. 

The product must be returned to the factory for repair.

Warning

These products are intended for use in industrial compressed air systems only. Do not use these products where 

pressures and temperatures can exceed those listed under SPECIFICATIONS.
Before using these products with fluids other than those specified, for non-industrial applications, life-support systems, 

or other applications not within published specifications, consult ASCO Numatics.
Through misuse, age, or malfunction, components used in fluid power systems can fail in various modes.

The system designer is warned to consider the failure modes of all component parts used in fluid power 

systems and to provide adequate safeguards to prevent personal injury or damage to equipment in the 

event of such failure.

System designers must provide a warning to end users in the operating manual if protection against a failure mode 

cannot be adequately ensured.
System designers and end users are cautioned to review specific warnings found in instruction sheets packed and 

shipped with these products.

Содержание Asco SentronicPLUS

Страница 1: ...Installation Manual SentronicPLUS IO Link CLASS A Electronic Pressure Regulator ...

Страница 2: ...formation Fluid Temperature 0 ºC to 60 ºC 32 F to 140 F Command Signal IO Link PSI Pressure Ranges PA PB 50 100 psi ranges in digital steps of 0 01 psi PC 150 psi range in digital steps of 0 1 psi Bar Pressure Ranges 40 50 60 V1 V2 V3 100mbar 500mbar 1bar all vacuum in digital steps of 0 0001 bar All others in digital steps of 0 001 bar Ports 1 8 1 4 NPT or GTap Construction Direct operated Poppet...

Страница 3: ...anges Available on Request Digital Output 1 Standard Output Pressure psi 40 0 0 1 bar 1 5 50 0 0 5 bar 7 3 60 0 1 bar 14 5 02 0 2 bar 29 03 0 3 bar 44 PA 0 3 4 bar 50 05 0 5 bar 73 06 0 6 bar 87 PB 0 6 9 bar 100 10 0 10 bar 145 PC 0 10 3 bar 150 12 0 12 bar 174 Options A00 Dual loop control 018 Oxygen clean 6 1 4 3 5 7 E 9 0 1 1 PB How to Order Operating Modes Shut off If the setpoint falls below ...

Страница 4: ... 0 43 11 2 18 55 3 4 15 105 3 4 52 114 7 1 42 36 2 68 68 2 05 52 1 69 43 1 38 35 A Thread M5 depth 10 on opposite side tapped through hole for M4 screw 1 4 NPT or GTap Weight 1 87 0 85 1 8 NPT or GTap DN3 Weight 1 21 0 55 PE 4 8 deep 0 98 25 2 24 57 3 x 1 8 8 deep 0 59 15 0 98 25 1 14 29 1 38 35 3 75 95 2 3 17 80 5 1 02 26 0 39 10 0 71 18 0 98 25 2 x M4 10 deep Dimensions Inches mm Weight in lbs k...

Страница 5: ...Double Ended Cable Unshielded TD0505MIETA0571P 5 Meter TD0510MIETA0571P 10 Meter M12 90 5 Pin Female Single Ended Cable Unshielded TD0505MIE000071P 5 Meter TD0510MIE000071P 10 Meter M12 Straight 5 Pin Female to Male Double Ended Cable Unshielded TC0505MIETA0571P 5 Meter TC0510MIETA0571P 10 Meter M12 Straight 5 Pin Female Single Ended Cable Unshielded TC0505MIE000071P 5 Meter TC0510MIE000071P 10 Me...

Страница 6: ...nder pressure when a setpoint signal is applied to the valve applying a setpoint signal with no pressure on the valve will cause it to overheat 6 The valve is factory adjusted 7 The product must be returned to the factory for repair Warning These products are intended for use in industrial compressed air systems only Do not use these products where pressures and temperatures can exceed those liste...

Страница 7: ...pain 34 942 87 6100 United Kingdom 44 1695 713600 France 33 2 37 24 42 24 Germany 49 7237 9960 India 91 44 39197300 Italy 39 02 356931 Japan 81 798 65 6361 Mexico 52 55 5809 5640 Australia 61 2 9 451 7077 Brazil 55 11 4208 1700 Canada 1 519 758 2700 China 86 21 3395 0000 Czech Republic 420 235 090 061 Dubai UAE 971 4 811 8200 Global Contacts 4 19 ...

Отзывы: