Table A-11: Machine Temperature
(continued)
Axis
Severity
Upper Limit
Lower Limit
Units
Notes
Machine
Temperature
Sensor
95
-50
°C
Read-only
Machine
Temperature
Range
95
-50
°C
Can be set by
the user up to
the sensor
range
Machine Temp Fail
75
-40
°C
Machine
Temperature
Maint
70
-35
°C
Machine
Temperature
Advise
65
-30
°C
Table A-12: Supply Voltage
Axis
Severity
Upper Limit
Lower Limit
Units
Notes
Supply
Voltage
Saturated
3.75
0
V
Read-only
Supply
Voltage
Sensor
3.75
0
V
Read-only
Supply
Voltage
Range
3.7
2.3
V
Read-only
Supply
Voltage
Fail
Not Applicable 2.7
V
Read-only
Supply
Voltage
Maint
Not Applicable 2.85
V
Supply
Voltage
Advise
Not Applicable 3
V
Table A-13: Speed
Axis
Severity
Upper Limit
Lower Limit
Units
Notes
Speed
Saturated
10000
0
rpm
Limits
calculated by
device and not
user settable.
Speed
Sensor
10000
0
rpm
Limits
calculated by
device and not
user settable.
Speed
Range
3000
0
rpm
Limits
calculated by
device and not
user settable.
Specifications and reference data
User Guide
August 2020
MHM-97927-PBF
70
MHM-97927-PBF, Rev 1
Содержание AMS Wireless Vibration Monitor
Страница 1: ...User Guide MHM 97927 PBF Rev 1 August 2020 AMS Wireless Vibration Monitor User Guide ...
Страница 42: ...Configuration User Guide August 2020 MHM 97927 PBF 42 MHM 97927 PBF Rev 1 ...
Страница 50: ...Installation User Guide August 2020 MHM 97927 PBF 50 MHM 97927 PBF Rev 1 ...
Страница 80: ...Product certifications User Guide August 2020 MHM 97927 PBF 80 MHM 97927 PBF Rev 1 ...
Страница 82: ...Third party licenses User Guide August 2020 MHM 97927 PBF 82 MHM 97927 PBF Rev 1 ...
Страница 85: ...User Guide MHM 97927 PBF August 2020 MHM 97927 PBF Rev 1 85 ...