Safety
Information
Product
Information
Mechanical
Installation
Electrical
Installation
Getting
Started
Basic
parameters
Running
the motor
Optimization
SMARTCARD
operation
PC tools
Advanced
parameters
Technical
Data
Diagnostics
UL Listing
Information
Affinity User Guide
95
Issue Number: 5 www.controltechniques.com
i.e. if the last parameter is displayed, a further press will cause the
display to rollover and show the first parameter.
When changing between menus the drive remembers which parameter
was last viewed in a particular menu and thus displays that parameter.
Figure 5-5 Menu structure
5.4 Menu 0
Menu 0 is used to bring together various commonly used parameters for
basic easy set up of the drive.
Appropriate parameters are copied from the advanced menus into menu
0 and thus exist in both locations.
For further information, refer to Chapter 6
Figure 5-6 Menu 0 copying
5.5 Advanced menus
The advanced menus consist of groups or parameters appropriate to a
specific function or feature of the drive.
Table 5-1 Advanced menu descriptions
5.5.1 Keypad set-up menus
Table 5-2 Menu 40 parameter descriptions
Menu 0
....XX.00....
0.50
0.49
0.48
0.47
0.46
0.01
0.02
0.03
0.04
0.05
Moves
between
parameters
Menu 41
Menu 1
Menu 2
Menu 40
Moves between Menus
41.50
41.49
41.48
41.47
41.46
41.01
41.02
41.03
41.04
41.05
1.01
1.02
1.03
1.04
1.05
1.50
1.49
1.48
1.47
1.46
Menu 0
0.04
0.05
0.06
Menu 2
2.21
Menu 1
1.14
Menu 4
4.07
5
0
150
0
150
5
Menu
Description
0
Commonly used basic set up parameters for quick / easy
programming
1
Frequency / speed reference
2
Ramps
3
Slave frequency, speed feedback and speed control
4
Torque and current control
5
Motor control
6
Sequencer and clock
7
Analog I/O
8
Digital I/O
9
Programmable logic, motorized pot and binary sum
10
Status and trips
11
General drive set-up
12
Threshold detectors and variable selectors
14
User PID controller
15, 16 Solutions Module set-up
17
Building automation network
18
Application menu 1
19
Application menu 2
20
Application menu 3
21
Second motor parameters
22
Additional Menu 0 set-up
40
Keypad configuration menu
41
User filter menu
Parameter
Range(
Ú
)
40.00 Parameter 0
0 to 32767
40.01 Language selection
English (0), Custom (1),
French (2), German (3),
Spanish (4), Italian (5)
40.02 Software version
999999
40.03 Save to flash
Idle (0), Save (1), Restore (2),
Default (3)
40.04 LCD contrast
0 to 31
40.05
Drive and attribute database
upload was bypassed
Updated (0), Bypass (1)
40.06 Browsing favourites control
Normal (0), Filter (1)
40.07 Keypad security code
0 to 999
40.08
Communication channel
selection
Disable (0), Slot1 (1), Slot2 (2),
Slot3 (3), Slave (4), Direct (5)
40.09 Hardware key code
0 to 999
40.10 Drive node ID (Address)
0 to 255
40.11 Flash ROM memory size
4Mbit (0), 8Mbit (1)
40.19
String database version
number
0 to 999999
40.20
Screen saver strings and
enable
None (0), Default (1), User (2)
40.21 Screen saver interval
0 to 600
40.22 Turbo browse time interval
0 to 200ms
40.23 Product identification
Unidrive SP (0), Commander
SK (1), Mentor MP (2),
Commander GP20 (3)
Affinity (4), Digitax (5)
Содержание Affinity