Reference Manual
00809-0100-4793, Rev CA
August 2004
Rosemount 8742C
A-18
Table A-8. Rosemount 8705 and 8707 Dimensions in Inches (Millimeters) (Dimensions with ASME B16.5 (ANSI)
Flanges)
(1)
Refer to Dimensional Drawings, Figure 2, Figure 3, and Figure 4
Line Size
(2)
and
Flange Rating
Body Height
“H”
Liner Face
Diameter
“A”
Overall Flowtube
Length
“L”
(3)
Flange Diameter
“D”
Liner Thickness
Inside Diameter
0.5–150
0.5–300
0.5–600
6.75 (171)
6.75 (171)
6.75 (171)
1.38 (35)
1.38 (35)
1.38 (35)
7.88 (200)
7.88 (200)
8.67 (220)
3.50 (89)
3.75 (95)
3.75 (95)
0.09 (2.3)
0.09 (2.3)
0.09 (2.3)
0.49 (12.5)
0.49 (12.5)
0.49 (12.5)
1–150
1–300
1–600
1–900
6.75 (171)
6.75 (171)
6.75 (171)
6.75 (171)
2.00 (51)
2.00 (51)
1.62 (41)
1.62 (41)
7.88 (200)
7.88 (200)
8.67 (220)
9.66 (245)
4.25 (108)
4.88 (124)
4.88 (124)
5.88 (149)
0.09 (2.3)
0.09 (2.3)
0.09 (2.3)
0.13 (3.3)
0.91 (23)
0.91 (23)
0.91 (23)
0.80 (20)
1.5–150
1.5 –300
1.5–600
1.5–900
7.10 (180)
7.10 (180)
7.10 (180)
7.10 (180)
2.88 (73)
2.88 (73)
2.88 (73)
2.50 (64)
7.88 (200)
7.88 (200)
8.63 (219)
9.52 (242)
5.00 (127)
6.12 (155)
6.12 (155)
7.00 (178)
0.12 (3.1)
0.12 (3.1)
0.13 (3.3)
0.13 (3.3)
1.44 (37)
1.44 (37)
1.36 (35)
1.25 (32)
2–150
2–300
2–600
2–900
7.10 (180)
7.10 (180)
7.10 (180)
7.10 (180)
3.62 (92)
3.62 (92)
3.62 (92)
3.25 (83)
7.88 (200)
7.88 (200)
8.78 (223)
10.26 (261)
6.00 (152)
6.50 (165)
6.50 (165)
8.50 (216)
0.12 (3.1)
0.12 (3.1)
0.13 (3.3)
0.13 (3.3)
1.91 (49)
1.91 (49)
1.82 (46)
1.69 (43)
3–150
3–300
3–600
3–900
8.10 (206)
8.10 (206)
8.10 (206)
8.10 (206)
5.00 (127)
5.00 (127)
5.00 (127)
4.63 (118)
7.88 (200)
8.63 (219)
12.4 (315)
12.8 (326)
7.50 (191)
8.25 (210)
8.25 (210)
9.50 (241)
0.15 (3.8)
0.15 (3.8)
0.13 (3.3)
0.13 (3.3)
2.96 (75)
2.96 (75)
2.76 (70)
2.37 (60)
4–150
4–300
4–600
4–900
8.45 (215)
8.45 (215)
8.45 (215)
8.45 (215)
6.19 (157)
6.19 (157)
6.19 (157)
5.81 (148)
9.84 (250)
10.88 (276)
12.83 (326)
13.89 (353)
9.00 (229)
10.00 (254)
10.75 (273)
11.50 (292)
0.15 (3.8)
0.15 (3.8)
0.13 (3.3)
0.13 (3.3)
3.96 (101)
3.96 (101)
3.72 (95)
3.37 (86)
6–150
6–300
6–600
6–900
9.45 (240)
9.45 (240)
9.45 (240)
9.45 (240)
8.50 (216)
8.50 (216)
8.50 (216)
8.00 (203)
11.81 (300)
13.06 (332)
14.23 (361)
15.51 (394)
11.00 (279)
12.50 (318)
14.00 (356)
15.00 (381)
0.19 (4.8)
0.19 (4.8)
0.19 (4.8)
0.16 (4.1)
5.98 (152)
5.69 (144)
5.69 (144)
4.86 (123)
8–150
8–300
8–600
8–900
10.42 (265)
10.42 (265)
10.42 (265)
10.42 (265)
10.62 (270)
10.62 (270)
10.62 (270)
10.00 (254)
13.78 (350)
15.60 (396)
16.72 (428)
18.47 (469)
13.50 (343)
15.00 (381)
16.50 (419)
18.50 (470)
0.19 (4.8)
0.17 (4.3)
0.17 (4.3)
0.17 (4.3)
7.94 (202)
7.64 (194)
7.64 (194)
6.65 (169)
10–150
10–300
10–600
11.78 (299)
11.78 (299)
11.78 (299)
12.75 (324)
12.75 (324)
12.75 (324)
15.00 (381)
17.13 (435)
19.54 (496)
16.00 (406)
17.50 (444)
20.00 (508)
0.26 (6.5)
0.26 (6.5)
0.26 (6.5)
9.87 (251)
9.48 (241)
9.21 (234)
12–150
12–300
12.86 (327)
12.86 (327)
15.00 (381)
15.00 (381)
18.00 (457)
20.14 (512)
19.00 (483)
20.50 (52)
0.26 (6.7)
0.26 (6.7)
11.87 (301)
11.48 (292)
14–150
14–300
13.92 (354)
13.92 (354)
16.25 (413)
16.25 (413)
21.00 (533)
23.25 (591)
21.00 (533)
23.00 (584)
0.19 (4.8)
0.19 (4.8)
13.16 (334)
12.79 (325)
16–150
16–300
14.93 (379)
14.93 (379)
18.50 (470)
18.50 (470)
24.00 (610)
26.25 (667)
23.50 (597)
25.50 (648)
0.19 (4.8)
0.19 (4.8)
15.12 (384)
14.75 (375)
18–150
18–300
16.19 (411)
16.19 (411)
21.00 (533)
21.00 (533)
27.00 (686)
30.12 (765)
25.00 (635)
28.00 (711)
0.19 (4.8)
0.19 (4.8)
17.09 (434)
16.35 (415)
20–150
20–300
17.20 (437)
17.20 (437)
23.00 (584)
23.00 (584)
30.00 (762)
33.25 (845)
27.50 (698)
30.50 (774)
0.19 (4.8)
0.19 (4.8)
18.96 (482)
18.21 (463)
24–150
24–300
19.48 (495)
19.48 (495)
27.25 (692)
27.25 (692)
36.00 (914)
39.64 (1007)
32.00 (813)
36.00 (914)
0.19 (4.8)
0.19 (4.8)
22.94 (583)
22.06 (560)
30
36
22.23 (565)
26.10 (663)
33.80 (859)
40.27 (1023)
37.25 (946)
40.88 (1038)
38.75 (984)
46.00 (1168)
0.19 (4.8)
0.19 (4.8)
28.75 (730)
29.08 (739)
(1) AS2129 Table D and E flange dimensions match ANSI 150# dimensions.
(2) 30- and 36-inch AWWA C207 Table 2 Class D rated to 150 psi at 150 °F.
(3) When 2 grounding rings are specified, add 0.25 inch (6.35 mm) for 0.50- through 14-inch (15 through 350 mm) flowtubes, add 0.50 inch (12.7 mm) for
16-inch (400 mm) and larger. When lining protectors are specified, add 0.25 inch (6.35 mm) for ½- through 12-inch (15 through 300 mm) flowtubes, add
0.50 inch (12.7 mm) for 14- through 36-inch (350 through 900 mm) flowtubes.
Содержание 8700 Series
Страница 2: ......
Страница 4: ......
Страница 12: ...Reference Manual 00809 0100 4793 Rev CA August 2004 1 4 Rosemount 8742C ...
Страница 64: ...Reference Manual 00809 0100 4793 Rev CA August 2004 5 12 Rosemount 8742C ...
Страница 102: ...Reference Manual 00809 0100 4793 Rev CA August 2004 Rosemount 8742C A 32 ...
Страница 116: ...Reference Manual 00809 0100 4793 Rev CA August 2004 Rosemount 8742C B 14 ...
Страница 135: ......