Rosemount 8742C
Table 2-2. Cable Requirements
Remote transmitter installations require equal lengths of signal and coil drive
cables. Integrally mounted transmitters are factory wired and do not require
interconnecting cables.
Lengths from 5 to 1,000 feet (1.5 to 300 meters) may be specified, and will be
shipped with the flowtube.
Flowtube to Remote
Mount Transmitter
Connections
Connect coil drive and electrode cables as shown in Figure 2-7.
Do not connect ac power
to the flowtube or to terminals 1 and 2 of the
transmitter
, or replacement of the electronics board will be necessary.
Figure 2-7. Wiring Diagram
Description
Part Number
Signal Cable (20 AWG) Belden 8762, Alpha 2411 equivalent
08712-0061-0001
Coil Drive Cable (14 AWG) Belden 8720, Alpha 2442 equivalent
08712-0060-0001
Combination Signal and Coil Drive Cable (18 AWG)
(1)
Belden 9368 equivalent
(1) Combination signal and coil drive cable is not recommended for
high-signal magmeter system. For remote mount installations, combination signal and coil drive
cable should be limited to less than 100 ft. (30 m).
08712-0750-0001