Reference Manual
00809-0100-4308, Rev BA
Appendix E: Mapping of Alert Messages in the
HART command 48 Additional Status Field
December 2014
Mapping of Alert Messages in the HART command 48 Additional Status Field
Table E-2. Maintenance Alerts (M:)
Table E-3. Advisory Alerts (A:)
Message
Additional Status
(1)
(1) Location of the Alert in the HART command 48 Additional Status field.
Description
Supply Voltage Low
Byte 8::Bit 4
The supply voltage is low and may affect
Device Operation.
Electronics Temperature Out of Limits
Byte 1::Bit 2
The temperature of the electronics board has
exceeded the transmitter’s operating range.
Level Measurement Lost
Byte 3::Bit 1
No valid Level reading. Reasons may be
multiple:
• No valid surface echo peak in the measuring
range.
• Incorrect transmitter configuration.
Simulation Active
Byte 8::Bit 0
The device is in simulation mode and is not
reporting actual information.
Low Signal Quality
Byte 5::Bit 0
The Signal Quality is below the defined alert
limit.
Interface Measurement Lost
Byte 3::Bit 0
No valid Interface reading. Reasons may be
multiple:
• No valid surface echo peak in the measuring
range.
• Incorrect transmitter configuration.
Capacity Denied
Byte 12::Bit 0
The device has failed to require all of the
necessary wireless bandwidth to broadcast at
the configured rate(s).
Message
Additional Status
(1)
(1) Location of the Alert in the HART command 48 Additional Status field.
Description
Database Memory Warning
Byte 0::Bit 2
The device has failed to write to the database
memory at some time in the past. Any data
written during this time may have been lost.
Non-Critical User Data Warning
Byte 2::Bit 1
A user written parameter does not match
expected value.
Volume Range Warning
Byte 4::Bit 7
The level measurement is outside the
configured volume range.
Button Stuck
Byte 1::Bit 5
The button on the Electronics Board is
detected as stuck in the active position.
HiHi Level Alert
Byte 5::Bit 4
The level is above the defined limit.
Hi Level Alert
Byte 5::Bit 5
The level is above the defined limit.
Lo Level Alert
Byte 5::Bit 6
The level is below the defined limit.
LoLo Level Alert
Byte 5::Bit 7
The level is below the defined limit.
User Defined Alert
Byte 5::Bit 3
The variable has surpassed the user defined
limit.
Содержание 3308A Rosemount 3308 Series
Страница 2: ......
Страница 6: ...vi Reference Manual 00809 0100 4308 Rev BA Title Page December 2014 ...
Страница 12: ...vi Reference Manual 00809 0100 4308 Rev BA Table of Contents December 2014 Table of Contents ...
Страница 14: ...2 Reference Manual 00809 0100 4308 Rev BA Section 1 Introduction December 2014 Introduction ...
Страница 24: ...12 Reference Manual 00809 0100 4308 Rev BA Section 2 Transmitter Overview December 2014 Transmitter Overview ...
Страница 52: ...40 Reference Manual 00809 0100 4308 Rev BA Section 3 Installation December 2014 Installation ...
Страница 72: ...60 Reference Manual 00809 0100 4308 Rev BA Section 4 Configuration December 2014 Configuration ...
Страница 80: ...68 Reference Manual 00809 0100 4308 Rev BA Section 5 Operation December 2014 Operation ...
Страница 150: ...138 Reference Manual 00809 0100 4308 Rev BA Appendix A Reference Data December 2014 Reference Data ...
Страница 162: ...150 Reference Manual 00809 0100 4308 Rev BA Appendix B Product Certifications December 2014 Product Certifications ...
Страница 196: ...4 Reference Manual 00809 0100 4308 Rev BA Index December 2014 Index ...
Страница 197: ......