background image

12

PROGRAMMING 

Cooling

Program

Wake Up

(Morning)

Fan

Leave For Work

(Day)

Fan

 Return Home

(Evening)

Fan

Go To Bed 

 (Night)

Fan

MON

6:00 AM

75°F

Auto 8:00 AM

83°F

Auto 5:00 PM

75°F

Auto 10:00 PM

78°F

Auto

TUE

WED

THU

FRI

SAT

6:00 AM

75°F Auto 8:00 AM

83°F

Auto 5:00 PM

75°F

Auto 10:00 PM

78°F

Auto

SUN

6:00 AM

75°F

Auto 8:00 AM

83°F

Auto 5:00 PM

75°F

Auto 10:00 PM

78°F

Auto

Worksheet for Re-Programming 5+1+1 and 7 Day Program

Heating

Program

Wake Up

(Morning)

Fan

Leave For Work

(Day)

Fan

 Return Home

(Evening)

Fan

Go To Bed 

 (Night)

Fan

MON

6:00 AM

70°F

Auto 8:00 AM

62°F

Auto 5:00 PM

70°F

Auto 10:00 PM

62°F

Auto

TUE

WED

THU

FRI

SAT

6:00 AM

70°F Auto 8:00 AM

62°F

Auto 5:00 PM

70°F

Auto 10:00 PM

62°F

Auto

SUN

6:00 AM

70°F

Auto 8:00 AM

62°F

Auto 5:00 PM

70°F

Auto 10:00 PM

62°F

Auto

Wired Remote Temperature Sensing

One remote temperature sensor can be installed indoor or 
outdoor and connected to the thermostat by a maximum 
cable length of 100 meters (300 feet). Ter, S and - on 
the terminal block allow connection of the remote sensor. 
The thermostat must have 24 VAC Common connection 
to terminal C for the remote sensor to operate. The 
remote sensor can be enabled or disabled in the Installer/
Configuration menu, item 29.
When remote sensor, 

Remote

, is selected 

Off 

(factory 

default), no remote sensor is enabled. When remote sensor is 
selected 

On

, the next step is to select the remote as indoor, 

Remote In

, or outdoor, 

Outdoor Remote

. If the remote is 

selected as Remote In, an additional step will be to select 

if the temperature shown on the display will be from the 
thermostat, 

LS On

, or the remote sensor 

LS Off

.

In normal operation, when a remote sensor is enabled the 
time digits of the display will alternate between the time and 
the remote temperature for three seconds each. Above the 
remote temperature will be Remote, for indoor sensor or 

Outdoor Remote

, for outdoor sensor. If the remote sensor is 

an indoor sensor and the local display has been disabled, the 
temperature displayed as the room temperature will be the 
remote sensor temperature.
Sensing Range: 
Outdoor temperature range is -40

o

F to 140

o

Indoor temperature range is 32

o

F to 99

 o

F

Содержание 1F95-1277

Страница 1: ...tain mercury However this product may replace a product that contains mercury Mercury and products containing mercury must not be discarded in household trash Do not touch any spilled mercury Wearing non absorbent gloves clean up any spilled mercury and place in a sealed container For proper disposal of a product containing mercury or a sealed container of spilled mercury place it in a suitable sh...

Страница 2: ... The Power Stealing Switches Fig 1 should be left in the On position for most systems The information in the following table details the thermostat power method and switch options WARNING Thermostat installation and all components of the control system shall conform to Class II circuits per the NEC code INSTALLATION Figure 1 Thermostat Base Multi Stage 1F95 1277 2 AA Batteries Power Stealing Switc...

Страница 3: ... 1 compressor when auxiliary heat is energized Heat mode 3rd stage Emergency Mode 1st stage Note Dual Fuel option de energizes Heat mode stages 1 and 2 both compressors when auxiliary heat is energized Heat mode 4th stage Emergency Mode 2nd stage Note Dual Fuel option de energizes Heat mode stages 1 and 2 both compressors when auxiliary heat is energized Heat mode 3rd stage Emergency Mode 2nd stag...

Страница 4: ...7 8 9 1 0 1 1 1 2 1 3 1 4 1 5 1 6 1 7 1 8 1 9 2 0 2 1 2 2 2 3 2 4 2 5 2 6 2 7 2 8 2 9 3 0 3 1 3 2 3 3 3 4 3 5 3 6 3 7 3 8 3 9 3 19 20 2 1 11 10 15 16 9 8 17 13 12 4 18 Savings display indicates the feature is active 15 Remote indicates that the indoor remote temperature sensor is being accessed Outdoor Remote indi cates the outdoor remote temperature sensor is being accessed 16 Display time remote...

Страница 5: ...Management Recovery Not available if 4 is 0 8 FA Heat Cr SL Selects Adjustable Anticipation cycle rate Heat 9 FA Cool Cr SL Selects Adjustable Anticipation cycle rate Cool 10 FA Cr AU Em SL Selects Adjustable Anticipation cycle rate auxiliary This item is only to appear if HP1 or HP2 is selected above 11 OFF SC On Select stage cycle completion On or Off 12 OFF CL On Selects Compressor Lockout 13 O...

Страница 6: ...s fast cycle FA Cr in all modes Heat Cool Em To change to slow cycling SL Cr press touch keys or toggle between FA SL The cycle rates are below Mode Med Slow Heat 0 6 F 1 5 F Cool 1 2 F 1 7 F Heat Pump 1 2 F 1 7 F Emer Heat 0 6 F 1 7 F 11 Stage Cycle Completion SC Selecting SC ON will cause the thermostat to complete heating and or cooling cycles on the highest stage engaged during the cycle Therm...

Страница 7: ...sh on the thermostat Refer to Com fort Alert Codes in Troubleshooting section If a Comfort Alert module is not connected or to disable active protec tion turn this feature OFF If a Comfort Alert module is connected and this feature is turned OFF the thermostat will still receive and flash the fault codes from the Comfort Alert module but the active protection will not be enabled to protect the com...

Страница 8: ...heat and shut down the compressor When the outdoor temperature falls below the selected tem perature the gas heat will begin Default is 35 but can be set in the range of 5 to 50 A lower setting will delay the start of gas heat allowing cooler temperature in the home INSTALLER CONFIGURATION MENU 35 Select Dual Fuel Setting With DF selected On and no outdoor sensor select the dF setting from 01 09 F...

Страница 9: ...he SYSTEM key to select Cool Thermostat controls only the cooling system Off Heating and Cooling systems are off Heat Thermostat controls only the heating system Em Setting is available only when the thermostat is configured in HP1 or HP2 mode Auto Auto Changeover is used in areas where both heating and cooling may be required on the same day AUTO allows the thermostat to automatically select heat...

Страница 10: ... will disappear and the day s you copied to will be on 6 If you wish to copy this same program into other days press Copy and repeat steps 3 4 and 5 7 Press Run Schedule to return to normal operation Fill in the blank schedule on the next page then Enter the Heating Program 1 Press the Menu key and then press Set Schedule Press SYSTEM key to select Heat in the system switch area indicating the act...

Страница 11: ...equired Wake Up Morning Leave For Work Day Return Home Evening Go To Bed Night Heating Program 6 00 AM 70 F 8 00 AM 62 F 5 00 PM 70 F 10 00 PM 62 F Cooling Program 6 00 AM 75 F 8 00 AM 83 F 5 00 PM 75 F 10 00 PM 78 F Programmable Fan Option In the Set Schedule mode the Fan key is used to select the fan operation during a program period The default state of the Fan key is FAN Auto fan runs during a...

Страница 12: ... on the terminal block allow connection of the remote sensor The thermostat must have 24 VAC Common connection to terminal C for the remote sensor to operate The remote sensor can be enabled or disabled in the Installer Configuration menu item 29 When remote sensor Remote is selected Off factory default no remote sensor is enabled When remote sensor is selected On the next step is to select the re...

Страница 13: ... the dual fuel temperature setpoint menu item 33 can be set to a temperature of 5 through 50 When outdoor remote sensor is not installed a software logic based dual fuel number menu item 34 from 01 to 09 can be selected A higher temperature or dual fuel setting will provide a smaller stage separation between the heat pump and Aux to give more comfort A lower temperature or number will provide a la...

Страница 14: ... FAN Switch set to Fan ON Check each wire connection to verify they are not shorted or touching together No bare wire should stick out from under terminal block Try resetting the thermostat as de scribed above If the condition persists the manufacturer of your system or service person can instruct you on how to test the Heat Cool system for correct operation If the system operates correctly replac...