Emerson Power Transmission Kop-Flex KOP-GRID H Series Скачать руководство пользователя страница 2

2

© Emerson Power Transmission Manufacturing, L. P. 1998. All Rights Reserved.

The most reliable test of a suitable lubricant is often the result
of user experience and satisfaction. If a lubricant has been
known to sludge, separate into heavy components or dry out,
consider the use of KOP-FLEX

®

 KSG grease.

1. HUB INSTALLATION

Verify all parts are on hand and are as ordered, check that
the hub bores are correct. Prepare shafts by removing dirt
and burrs. Lightly apply grease on seals and place them on
shafts, before installing the hubs. Mount the hubs on their
shafts, with hub face flush with the shaft end. Properly tighten
setscrews when furnished. For vertical shafts, seal the key-

Figure 2

2.  SHAFT SEPARATION & ANGULAR ALIGNMENT

Use a feeler gauge to measure the gap between hub faces at
4 points 90° apart. The gap should not exceed the value speci-
fied in Table 1. Position equipment to obtain best alignment.
The measured difference between minimum and maximum
value should not exceed the angular limit specified in Table 1.

Important Safety Instructions
Before start-up . . .
 for reasons of safety and to extend shaft
coupling life, follow these requirements.

1. Coupling guards protect personnel. ALL COUPLINGS

MUST BE COVERED WITH A GUARD AS PER OSHA
REQUIREMENTS.

2. Recheck alignment after all foundation bolts and mechani-

cal connections are tightened.

3. Make sure all fasteners are properly installed and tight-

ened.

4. Take the time to double check your work.

5. Only authorized Kop-Flex replacement parts are to be

used.

6. Call Kop-Flex for any clarification or questions.

WARNING

!

Failure to observe 
safety precautions 
could cause 
personal injury
or equipment 
damage.

INSTALL

SEAL

FIRST

HUB

FACE

Figure 1

way to prevent grease leakage. For interference fit, heat the
hub in an oven to 300°F (150°C) before mounting the hub.
NEVER exceed 600°F (300°C).

Note: Allow heated hubs to cool to room temperature
before coupling alignment and assembly.

Figure 3

3.  OFFSET ALIGNMENT

Use a straight edge and feeler gauge to align shafts at 4 points
90° apart. The offset (parallel misalignment) should not ex-
ceed the offset limit specified in Table 1.

Содержание Kop-Flex KOP-GRID H Series

Страница 1: ...ained and that the lubricant is free of contaminates In an average industrial application the coupling should be checked for lubricant contamination and replenished with the proper volume every twelve months Conditions such as very slow speed reversing drives high heat and severe environ ments may require more frequent lubrication RECOMMENDED LUBRICANT KOP FLEX KSG Coupling Grease This grease is s...

Страница 2: ...alue should not exceed the angular limit specified inTable 1 Important Safety Instructions Before start up for reasons of safety and to extend shaft coupling life follow these requirements 1 Coupling guards protect personnel ALL COUPLINGS MUST BE COVERED WITH A GUARD AS PER OSHA REQUIREMENTS 2 Recheck alignment after all foundation bolts and mechani cal connections are tightened 3 Make sure all fa...

Страница 3: ...egment s open ends are on the same side Figure 5 Figure 6 5 COVER INSTALLATION LUBRICATION Pack the grid with additional KSG grease or the equivalent and wipe off the excess flush with the top of the grid Slide seals over the hub and adjust to line up with the cover seal grooves Place gaskets on both flanges of the lower cover and install top cover Align cover match marks on the same side For vert...

Страница 4: ...OVER BOLT TORQUE LB IN ALLOWABLE MAXIMUM SPEED RPM LUBE GREASE WEIGHT LB OFFSET IN ANGULAR IN 1020 0 006 0 003 0 125 100 4 500 0 07 1030 0 006 0 003 0 125 100 4 500 0 07 1040 0 006 0 003 0 125 100 4 500 0 11 1050 0 008 0 004 0 125 200 4 500 0 11 1060 0 008 0 005 0 125 200 4 350 0 20 1070 0 008 0 005 0 125 200 4 125 0 24 1080 0 008 0 006 0 125 200 3 600 0 37 1090 0 008 0 007 0 125 200 3 600 0 55 11...

Отзывы: