- 5 - FN-108784.1
3.
4.
5.
OPERATING INSTRUCTIONS
1.
Plug the power cord into a suitable socket.
2.
Oscillation: To make the fan head oscillate, push down the oscillation knob. To stop the fan head from
oscillating, pull-up the oscillation knob.
3.
The fan is switched on by using the push buttons on the control panel, i.e. 0: Off, 1 = Low Speed, 2 =
Medium speed, 3 = High speed.
CAUTION:
Press only one of the speed control button at a time. Permanent damage to the switch housing may
result if two or more of the buttons are pressed simultaneously.
CLEANING
1.
Before servicing the fan and after each occasion of use, switch off the appliance and unplug the mains
cable from the socket.
2.
Never immerse the appliance in water (danger of short-circuit).
To clean the appliance, only wipe it
down with a damp cloth and dry it carefully. Always take out the mains plug first.
3.
Take care that excessive dust does not build up in the air-intake and air-outlet grille, and clean it
occasionally using a dry brush or vacuum cleaner.
TECHNICAL DATA
Operating voltage: 220-240V~ 50Hz
Power consumption: 44W
Eco design requirements
Product information requirements
Maximum fan flow rate (F)
40.19 m³/min
Fan power input (P)
36.32 W
Service value (SV)
1.11(m³/min)/W
Measurement standard for service value
IEC 60879: 1986
EN 50564: 2011
EN 60704-2-7: 1998
EN 60704-1: 2010
Standby power consumption (P
SB
)
0.00 W
Fan sound power level (L
WA
)
50.30 dB(A)
Maximum air velocity (c)
2.09 meters/sec
Contact details for obtaining more information
Emerio International AB
Smedjegatan 6
131 54 Nacka
Sweden