![EmergoPlus PowerXtreme XS20 Скачать руководство пользователя страница 22](http://html1.mh-extra.com/html/emergoplus/powerxtreme-xs20/powerxtreme-xs20_user-manual_2400122022.webp)
User manual MPPT Solar charge controller PowerXtreme XS20
E18-XS20-EN00
www.emergoplus.com
Page 22 of 44
Users can adjust the parameters to the actual conditions, but parameter
setting must take place under supervision of a competent person. Faulty
parameter settings may cause the system to not function properly. For
more information about parameter settings, see table 3.
Parameter setting reference table
No.
Item in
screen
Description
Parameter range
Standard setting
1
Type or
Bat
Battery
type
User/Lead-
acid/Maintenance-
free/Gel /Li
Maintenance-
free
2
VOLT or
SYS
System
voltage
12V / 24V
Auto
3
EQUALIZ
CHG
Equalizing
charging
voltage
9.0 to 17.0V
14.6V
4
BOOST
CHG
Boost
charging
voltage
9.0 to 17.0V
14.4V
5
FLOAT
CHG
Floating
battery
voltage
9.0 to 17.0V
13.8V
6
LOW
VOL
RECT
Diep
discharge
9.0 to 17.0V
12.6V
CAUTION!
After set-up of the system voltage power
needs to be switched off-and on again.