background image

1.

- To prevent electrical shock, do not mate unit connector until installation is complete and

CAUTION

power is supplied to the unit.

A.C.

3. The battery is sealed, non-maintenance, and is not replaceable in the field. Please contact manu-

facturer for information on service. Do not attempt to service the battery please.

4.

. The product is for use with grounded, UL Listed, indoor fixtures except in

heated air outlets or hazardous locations.

DO NOT USE OUTDOORS

5. The product requires an unswitched A.C. Power source of either 120 or 277 volts. Properly cap the

unused A.C. Lead.

6. Do not mount near gas or electric heaters.
7. The product should be mounted in locations and at heights where it will not readily be subjected to tam-

pering by unauthorized personnel.

9. The product is compatible with all A.C. magnetic and electronic ballasts including multiple lamp ballasts

with one lamp operating in the emergency mode.

FPDL-32

IMPORTANT SAFEGUARDS

When using electrical equipment, basic safety precautions should always be followed, including the following:

READ AND FOLLOW ALL SAFETY INSTRUCTIONS

SAVE THESE INSTRUCTIONS

Ni - Cd

INSTRUCTION MANUAL

EMERGILITE BRAND

2.

- This fixture provides more than one power supply output source. To reduce the risk of

electrical shock, disconnect both normal and emergency sources by turning off the A.C. Branch circuit
and by disconnecting the unit connector.

CAUTION

8. The product will cold strike and operate one 2

through 4

(20-40W) instant start, rapid start, U shape

or circline, T8 through T12 fluorescent lamps, T5 28W fluorescent lamps, including energy saving and
long compacts for 90 minutes at reduced light output.

10. The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition.

11. Do not use this equipment for other than intended use.
12. Install in accordance with the National Electrical Code and local regulations.
13. Installation and servicing should be performed by qualified personnel.
14. Lighting fixture manufacturers, electricians and end users need to ensure product system compatibility

before final installation.

15. The battery is sealed,non-maintenance,and is not replaceable in the field. Please contact

manufacturer for information on service. Do not attempt to service the battery please.

16. The rated operating time in the emergency mode with battery is 1-1/2 hours and the recharge

time shall not be less than 24 hours.

Page 1

CONTAINS NICKEL-CADMIUM

BATTERY.MUST BE RECYCLED

OR DISPOSED OF PROPERLY.

TEL

888 935 3605

: (

)

-

FAX

888 867 1565

: (

)

-

H

Отзывы: