background image

DESCRIPTION 

The unit is a photoelectric 220~240V AC, with 3V DC battery back-up smoke alarm device. It is particularly  

sensitive for detecting visible micro-particles (associated with smoldering fires) and reacts faster than  

ionization alarms. 
An example of such smoldering fires is a cigarette burning in a couch or bedding a common cause  

of devastating blazes. 
Please note this device does not detect flames, heat, carbon monoxide or other hazardous gases.  

It has many advanced features and an extended operational life with the included battery.
To enable interconnection with other Emerald RF smoke alarms add an RF module (EP-HYB-RF-MOD).

MODEL NUMBER: EP-HYB-240-10 

Thank you for choosing Emerald Alarms. 

This leaflet contains important information on the correct 

installation and operation of your smoke alarm. 
Please read all the information before commencing  

installation and retain for future reference.
This unit has been designed to meet the latest safety  

standards demanded in Australia and complies with the 

requirements of AS3786:2014.

POWER:

 

220~240V AC 50-60Hz with 3V battery backup (non-replaceable battery)

OPERATION CURRENT:

 <80mA

BATTERY LIFETIME:

 

10 years 

ALARM VOLUME:

 

>85dB (A) at 3 meters

ALARM SENSITIVITY:

 0.1-0.16dB/m

HUSH/SILENCE TIME:

 

approx. 8 minutes

INTERCONNECTION:

 

up to 24 smoke alarm/s, hardwired

COMPLY WITH:

 

AS3786: 2014

SOUND PATTERN:

 

 ISO8201 (Bl 0.5s - pause 0.5s - Bl 0.5s - pause 0.5s - Bl 0.5s - pause 1.5s,  

with the red LED flash, repeat this alarm pattern

WIRELESS INTERCONNECTION

 

Bl - Bl - pause 0.5s, Bl - Bl - pause 0.5s, Bl - Bl - pause 1.5s, 

ALARM SOUND PATTERN:

 

without the red LED flash, repeat this alarm pattern

SMOKE ALARM 