Emelson EMLCLE10SLGB-K Скачать руководство пользователя страница 14

- 13 - 

The water in the heater is not suitable for drinking. 

WARNING: 

Forbid any interference with a sealed component, 

a fire or explosion may result causing 

property damage, personal injury or loss of life.

 

Handle with abnormal conditions

If there is abnormal burning (flame light-back, flame lift, yellow tip or black smoke, etc), smell or noise,
or other emergent situations, keep calm and shut off the gas supply valve and power switch, and contact
the service facility or gas dealers for repair or adjustment.

Scald prevention

Do not look closely at the flame check window when igniting so as to avoid burning eyes. Keep 300mm
away.

When  using  the  heater  discontinuously,  be  careful  not  to  be  scalded  by  the  over  high  temperature  hot

water at the start and stop times.

During  use  and  immediately  after,  do  not  touch  any  places  especially  the  surround  of  the  flame  check

window or the front cover except for the knob and control panel in order to avoid scalding.

Maintenance 

Always check the gas pipe for cracks.

Clean the filter in the water inlet faucet monthly.

Always check for leaking water.

Ask qualified technicians to examine the burner, flue and fan once a year.

Always check the flame inside the water heater for any abnormal conditions.

Keep the cover of the water heater clean.

This product uses water pressure to open the channels. When the water pressure is lower than 0.2bar, the
heater cannot be ignited.

The drain valve is dripping. When the water pressure is too high, the drain valve will release the water so
as to reduce the pressure to protect the heater.

When the heater is supplying hot water to several points at the same time, the hot water flow would be
reduced, or no hot water will issue at all.

When the temperature outside is too low and the exhausted gas meets the cold air, it will be condense as
white fog. This is normal.

When the water temperature is too high, set to a lower temperature and reduce the water tap. If the water
temperature outlet is too high, please open the tap to reduce the temperature.

When  the  water  temperature  is  too  low,  and  the  hot  water  volume  is  so  high  so  that  it  exceeds  the
heater’s heating power, the outlet water will be not hot enough, please reduce the water volume.

In order to ignite immediately, the fan in the appliance will delay running for a long time and then stop
automatically. This is normal.

When  you  use  the  multi-function  shower,  the  resistance  may  be  too  large,  and  the  water  inlet  pressure
will be too low or the water inlet volume will be too little (below the starting –up water volume), there
may be flameout or can not be ignited, please choose the suitable shower function.

Содержание EMLCLE10SLGB-K

Страница 1: ...english Thanks for choossing our product Please read carefully this manual before using the product OWNER AND INSTALLATION MANUAL CLOSED CHAMBER GAS WATER HEATER SL EMLCLE10SLGB K ...

Страница 2: ...e installing and operating Keep it for future reference Contents Special Advice1 2 Features 2 Model instruction 3 Parts Name 4 Dimensions 5 Specifications 7 Installation 8 Using methods 11 Safety attention 13 Daily maintenance 15 Error code 16 Circuit Diagram 17 Trouble Shooting 18 ...

Страница 3: ...w out only after opening the water supply tap Convenient adjustment Water volume and firepower adjusted independently very convenient to regulate the water temperature High efficiency energy saving Both the burner and heat exchanger are designed by using international advanced combustion theory with the feature of high efficiency and quality combustion performance Low water pressure ignition In or...

Страница 4: ... product s safety function is concluded by lab tests it will be influenced by the environment in the practical use Please respect use of this device and keep maintained in a good condition Model instruction Fig 1 b 10KM ...

Страница 5: ... 4 DIMENSION All the figures for reference see the product for real appearance ...

Страница 6: ...sulation grade Class I Electrical and water protection IPX4D IPX0 when installed as type B23 Ignition method Water control automatic pulse ignition Temperature control method Gas proportional valve automatic control Destination country AT BE CH DE DK ES FI FR GB GR IE IT NL PT NO SE Pipe joint Gas inlet G1 2 or G3 4 Water inlet G1 2 Water outlet G1 2 Exhaust pipe Φ100 external Φ60 internal WARNING...

Страница 7: ...ime of the heater or prevent normal working Fig 5 Do not to install the flue of the heater through the wall whose window can be opened because the waste gases may flow back into indoors if the window is opened during using operation Fig 6 Don t install the heater above the gas stoves or other heat sources Fig 7 The power of the heater is 230V 50Hz AC the power socket must have a reliable ground wi...

Страница 8: ...gas to the outdoor according to the strictest requirements It s not allowed to use the gas water heater without operating the flue correctly Installation position of flue terminal protruding through wall The minimum flue length is 650mm and the maximum flue length is 3000mm with one elbow Fig 12 Install the flue after the heater body is fixed First put the fixed flue through the hole in the wall t...

Страница 9: ...a leak NOTE No substance other than air carbon dioxide or nitrogen can be introduced into the gas piping NOTE If you have a leak shut off the gas After verifying the leak tighten appropriate fittings to stop leak Turn the gas on and check again with a soapy solution Never test for gas leaks using a match or flame Cold water inlet When facing the heater the cold water inlet is on your right and the...

Страница 10: ...ermanent dedicated ventilation directly to the outside Warning The surface of the B23 flue is very hot must use insulating refractory between the flue and combustible parts of the wall And the minimum thickness of the refractory insulation material must not less than 20mm The minimum size of ventilation must not less than 200cm2 B23 flue installed as follow pic Using methods FOR YOUR SAFETY READ B...

Страница 11: ...e When the valve is open while the switch is in off position the heater doesn t work only cold water flows out if hot water is needed press the switch to on position Close down the water valve the heater stops working but the fan will continue blowing the chamber for several seconds If you don t turn off the power then next time when you open the water valve the heater will work according to the w...

Страница 12: ... is out after use and do not forget to turn off the gas valve Fig 19 and power Always check the gas connectors for gas leakage with soapsuds If any gas leakage is detected open the room windows and doors At that moment do not ignite or operate the switch of electric appliances or plugs because the flame or electric spark can result in explosive accidents Fig 20 Heaters must use the gas type which ...

Страница 13: ...y discharge the combustion bi products to the outdoors and intake the combustion air from outdoors so as to keep the indoors air fresh and prevent incomplete combustion Otherwise it will cause danger or even death Too low or too high gas pressure leads to abnormal combustion At that moment stop using the water heater and get in contact with a service engineer Dust and accelerated carbon would bloc...

Страница 14: ...abnormal conditions Keep the cover of the water heater clean This product uses water pressure to open the channels When the water pressure is lower than 0 2bar the heater cannot be ignited The drain valve is dripping When the water pressure is too high the drain valve will release the water so as to reduce the pressure to protect the heater When the heater is supplying hot water to several points ...

Страница 15: ... other parts of water heater 6 After Cleaning put the front cover back Error Codes Error Code Description Reasons Repair E0 Inlet water temperature sensor Possible short in sensor may need replacement of sensor check wire to water temperature sensor it may be disconnected E1 Ignition fail or lost flame Hardware error in detecting the flame feedback No flame detection after ignition 6 seconds Lost ...

Страница 16: ...thermostat open Controller board error F2 Gas Valve driver circuit error Controller board error F3 The power of Gas Valve error Controller board error F4 Main Valve control circuit error Controller board error F5 Proportional Valve driver circuit error Controller board error F6 AD converter error Controller board error F7 Setting Switch error Controller board error ...

Страница 17: ... 16 Circuit diagram ...

Страница 18: ...n Abnormal pressure high Contact repairer low Water valve not open completely Open it completely Insufficient fresh air Improve ventilation till fresh air is enough Too high outside wind pressure C type Stop using temporarily Frozen Use after melt Insufficient water pressure Ask repairer to check water pressure Wrong temperature Regulation Turn the temperature knob properly Power failure or not sw...

Страница 19: ...arance No Names Quantity 1 Water heater 1 set 2 Gas inlet hose 1 piece 3 Water inlet hose 1 kit 4 Expansion bolts M6 1 kit 5 Mounting screws 4 piece 6 Customer advice 1 piece 7 Self tapping screws 4 pieces 8 Flue is packed in another carton 1 kit ...

Страница 20: ...C Industria nº 13 Polígono Industrial El Pedregar 08160 Montmeló Barcelona Spain Phone 0034 93 390 42 20 Fax 0034 93 390 42 05 info geinal com ...

Отзывы: