Emegear Xcollar Скачать руководство пользователя страница 2

& 

& 

 

 

 

3

Step

 

Easy

 

Application

 

in

 

30

 

seconds:

  

“S

A

X”

 

(SETUP

 

–ADJUST

 

 

X

STRAPS

 

APPLICATION)

 

#1:

 

SETUP

 

•    

Extend

 

the

 

XCollar

 

to

 

its

 

longest

 

setting.

 

Unfold

 

the

 

Back

 

Support

 

and

 

lock

 

it

 

in

 

place.

 

#2:

 

ADJUST

 

• 

Encircle

 

the

 

patient

 

and

 

capture

 

the

 

chin

 

before

 

connecting

 

the

 

buckle.

 

Note

 

that

 

the

 

chin

 

is

 

the

 

anchor

 

point,

 

so

 

ensure

 

that

 

the

 

chin

 

properly

 

captured

 

between

 

the

 

Chin

 

Strap

 

(in

 

front)

 

and

 

the

 

Foam

 

Padding

 

(below).

 

•  

While

 

holding

 

the

 

front

 

of

 

the

 

device

 

in

 

place,

 

use

 

the

 

“push

 

&

 

pull”

 

(Opposing

 

Forces)

 

method

 

to

 

adjust

 

Side

 

Straps

 

evenly

 

(circumference

 

adjustment).

 

•  

Extend

 

Chest

 

Support

 

Piece

 

until

 

firm

 

contact

 

with

 

the

 

upper

 

sternum

 

is

 

obtained

 

(height

 

adjustment).

 

#3:

 

X

STRAPS

 

APPLICATION

 

•  

Apply

 

X

Straps,

 

using

 

the

 

“push

 

&

 

pull”

 

(Opposing

 

Forces)

 

method,

 

to

 

the

 

corresponding

 

color

coded

 

Velcro

 

anchor

 

points

 

while

 

ensuring

 

to

 

maintain

 

tension

 

on

 

the

 

X

Straps.

 

This

 

integrates

 

anterior

 

and

 

posterior

 

pieces

 

to

 

splint

 

the

 

patient.

 

USE

 

DIRECT

 

OPPOSING

 

FORCES

 

IN

 

EVERY

 

STEP

 

OF

 

APPLICATION

 

After

 

a

 

completed

 

proper

 

application,

 

the

 

following

 

criteria

 

must

 

be

 

met:

 

 

Proper

 

capturing

 

of

 

the

 

chin.

 

 

Firm

 

Contact

 

of

 

Chest

 

Support

 

on

 

Upper

 

Sternum.

 

 

Tension

 

on

 

X

Straps.

 

After

 

XCollar

 

application,

 

you

 

may

 

proceed

 

to

 

secure

 

the

 

patient

 

to

 

the

 

spinal

 

board/vacuum

 

mattress/rescue

 

basket

 

by

 

applying

 

the

 

HEAD

 

RESTRAINT

 

SYSTEM

 

(HRS).

 

 

2

STEP

 

HRS

 

APPLICATION:

 

 

1

 

 

STACK,

 

SLIDE

 

and

 

STICK

 

 

Once

 

patient

 

is

 

on

 

the

 

spinal

 

board,

 

STACK

 

the

 

Occipital

 

Support

 

pieces

 

to

 

desired

 

height

 

as

 

needed

 

to

 

maintain

 

proper

 

alignment.

 

SLIDE

 

the

 

Occipital

 

Support

 

Pad

 

under

 

the

 

head.

 

Pull

 

the

 

clear

 

film

 

strip

 

to

 

STICK

 

the

 

Occipital

 

Support

 

Pad

 

to

 

the

 

spinal

 

board.

 

 

2

 

 

SECURING

 

STRAPS

 

APPLICATION

 

 

Remove

 

one

 

X

Strap

 

while

 

maintaining

 

tension,

 

then

 

place

 

the

 

black

 

side

 

of

 

the

 

square

 

end

 

to

 

the

 

XCollar

 

Velcro

 

anchor

 

point.

 

Reattach

 

X

Strap.

 

Wrap

 

the

 

securing

 

strap

 

to

 

the

 

spinal

 

board

 

to

 

take

 

off

 

the

 

slack.

 

DO

 

NOT

 

OVERTIGHTEN.

 

Repeat

 

on

 

opposite

 

side.

 

Airway

 

Management

 

1.

   

Loosen

 

the

 

Chin

 

Strap

,

 

remove

 

the

 

X

S

TRAPS

 

and

 

loosen

 

the

 

Side

 

Straps

 

if

 

necessary.

 

 

2.

 

Obtain

 

airway.

 

 

3.

 

Re

tighten

 

X

Straps

 

to

 

secure

 

XC

OLLAR

.

 

***For

 

extra

large

 

patients

 

it

 

may

 

be

 

necessary

 

to

 

temporarily

 

unclip

 

the

 

buckle

 

to

 

intubate***

 

www.training.xcollar.com

Отзывы: