Make sure that the testing object is in a tensionless state and do not use the test 
buzzer around wet environments. Additionally you have to make sure that the 
measuring lines are in a flawless condition.  

 

The test buzzer confirms continuity with an acoustic signal of 70 dB(a) at a distance 
of 22 cm.  

Maintenance 

When the test buzzer is used according to the instruction manual no particular maintenance 
is required. It is still possible that the test buzzer gets dirty from time to time. If this is the 
case the battery box can be cleaned with a moist towel and a little bit of mild household 
cleaner.  

4.1 

Battery change 

After some time of use the battery needs to be changed. This will be recognized when the 
test buzzer doesn’t work flawlessly anymore.  
After you have disconnected the test buzzer from all the measuring circuits, proceed as 
indicated below: 

1.  Open the battery box as showed on the picture below. 

2.  Remove the old battery and insert the new 9 V block battery (IEC 6 F 22) poled 

correctly.  

3.  Close the battery box. 

 

Dispose the old battery appropriately.  

 

The battery should be removed if the test buzzer is not being used during a longer 
period of time. 

Technical data 

Currant over test terminal 

24 mA (1 k

Ω) 

Voltage over test terminal 

9 V 

Resistance test range 

0 - 1 k

Ω 

Protected against external 
voltage up to 

36 V AC  

 

Intermittent alarm by 
alternating voltage 

No

 

LED visual indication 

No

 

Battery 

9 V (IEC 6 F 22) 

Length of test cable 

1 m 

Temperature range 

-5°C to +50°C 

Life expectancy 

10 years 

 

Sign of conformity, approves compliance of the valid EMC directive (2014/30/EU). The 
device is in compliance with the following standards: EN ISO 12100, EN 60204-1, EN 
61000-6-2, EN 61000-6-4, low voltage directive (2014/35/EU). 

 

 