Assembly and Installation Instructions
Note:
All information, illustrations and specifications in this manual are based on
the latest product information available. We reserve the right to make changes
at any time without notice.
MAINTENANCE
The A1100 Guardian is maintenance free. Periodic inspection of drop tube wear
due to corrosion is suggested.
Please leave these instructions with the owner/operator of the service station for
future reference.
For complete warranty information visit www.emcoretail.com
p/n 566785
Rev. V, 06/20
TABLE OF CONTENTS
Tools
2
Packing
List
2
Assembly
2-7
Procedure
3
Installation
7-8
General
Maintenance 8
Warranty
8
IMPORTANT:
Read these instructions completely and carefully before attempting to
install and operate this valve. Failure to do so may result in improper valve operation
allowing for a potential storage tank overfill. An overfilled tank can create extremely haz-
ardous fuel spills which may result in personal injury and property damage. For further
information, please call our Customer Service Department at (252) 243-0150.
IMPORTANT:
Veuillez lire ces instructions attentivement avant d’installer et d’exploiter
cette vanne. Ne pas le faire peut entraîner un fonctionnement incorrect de la vanne per-
mettant un potentiel débordement de la citerne de stockage. Un réservoir trop plein peut
créer des déversements de carburant extrêmement dangereuses qui peuvent entraîner
des blessures et des dommages matériels. Pour plus d’informations, s’il vous plaît com-
muniquer avec notre service à la clientèle au (252) 243-0150.
Self-Sealing Models
It is critical that the A0089-001 Fill Adapter be properly installed to allow
proper vapor flow. Improper installation can result in greatly reduce vapor
flow that will prevent a normal fuel drop.
Step 21:
Apply pipe dope to the adapt-
er and riser pipe threads. Position the
adapter on the riser and begin to turn
the adapter to engage the riser pipe
threads. Once the threads engage, turn
the A0089-001 adapter approximately
4 turns. (See photo below, right.) The
adapter is not designed to seal on the
riser. Apply minimal torque (30 ft. lbs.
max.) to seat the adapter. Do not over
torque. Tighten the set screws (7-10 ft.
lbs.) to secure the adapter to the riser
pipe once the adapter is positioned as described above.
Vapor path, pictured in sealed
position. The coax fill arm opens
the vapor seal approximately 1/2
the distance of the opening to
establish a flow path for the vapor
return.
A1100 GUARDIAN COAXIAL
OVERFILL PREVENTION SYSTEM
(with 493768 Installation Kit)
WARNING
:
If the underground storage tank is equipped with a ball float vent valve, make
sure it is not extended below the positive shut-off point of the A1100, or remove the float
vent valve.
ATTENTION:
Si le réservoir de stockage souterrain est équipé d’un flotteur évent de balle
vanne, assurez-vous qu’il n’est pas prolongée en dessous du point d’arrêt positive de
l’A1100, ou supprimer la vanne flotteur de ventilation.
CAUTION
:
Never disconnect the drop elbow from the tight-fill adapter when the A1100 has
reached the positive shut-off level. At this point, the tank truck hose is still full and must not
be disconnected until enough fuel has been removed from the underground storage tank to
drain the hose. Premature disconnection will result in a hazardous spill and a potential for
personal injury and property damage.
ATTENTION
: Ne jamais déconnecter le coude de baisse de l’adaptateur permet le remplis-
sage étanche lorsque le A1100 a atteint le niveau d’arrêt positive. A ce point, le tuyau de
camion-citerne est encore pleine et ne doit pas être débranché jusqu’à ce que suffisamment
de carburant a été éliminée du réservoir de stockage souterrain pour vidanger le tuyau.
Déconnexion prématurée entraîne un déversement dangereux et un risque de blessures et
de dommages matériels.