Troubleshooting Chart:
The following chart is an aid to determining and correcting the causes of faults that may occur in this
amplifier. Under normal operating conditions, the FINAL ON indicator should be illuminated green
with the TEMP and AMPL 1 indicators unlit. If a problem develops, note the type of problem, the
state of the indicator LEDs and % POWER meter and compare them to this chart. Refer to the
Troubleshooting Chart in the TTU20F Transmitter or TU20F Translator manual as necessary.
TROUBLESHOOTING CHART
PROBLEM
INDICATORS
CAUSE
SOLUTION
NO OUTPUT
POWER
ALL LEDs
UNLIT
No 32V or 5V available
Check plug connections
P9/P10 and 5V regulator
(U3) output on Indicator
Circuit board PC3.
Faulty module or 32V
Power Supply
Shut off Xmtr/Xltr RF
drive. While monitoring
the 32V supply, remove
the dc plug from each
module and PC board in
the drawer and the wire
harness to the driver. If
the 32V returns when a
plug is removed, replace
the associated module. If
32V does not return with
all plugs removed,
replace power supply.
TEMP
YELLOW
AMPL 1
GREEN
FINAL ON
GREEN
% POWER
0
DRIVER
STBY
High ambient temperature
inside drawer
Ensure fans are opera-
tional and are not
blocked.
Faulty thermostat
If amplifier A1 is cool,
measure resistance
across the thermostat.
Replace thermostat if a
short is present.
LOW OUTPUT
POWER OR
DISTORTED
OUTPUT
AMPL 1
RED
Faulty amplifier module
Replace amplifier module.
NO fault indicated
Output power calibration
is incorrect
See Section 3.5 or 3.6.