2
SVR-D2U-R710 Installation and Replacement Guide
Technical information and requirements
Technical information and requirements
Device power, cooling, and weight information
Device dimensions
Device placement requirements
There are no restrictions on the location of the server in the cabinet
(rack). Allow at least 30 inches
of service clearance in front of the
cabinet. Power distribution must support the number of outlets
required for the server and the server power rating listed in
power, cooling, and weight information.”
For additional information,
refer to the preparation/planning guides for your specific site and
cabinet.
Requirement
Description
AC line voltage
90-264 V AC, autoranging, 47-63 Hz
Wattage
570 W (Energy Smart)
Heat dissipation
1944.9 BTU/hr maximum (Energy Smart)
Maximum inrush current
Under typical line conditions and over the entire
system ambient operating range, the in-rush
current may reach 55 A per power supply for
10 ms or less.
Maximum weight
57.54 lb (26.1 kg)
Dimension
Server
Server with rails
Height
3.4 in (8.64 cm)
2.0 U (with or without
bezel)
Depth
28.4 in (72.06 cm) with
bezel
Adjustable
Width
17.4 in (44.31 cm)
without rack latches
48.24 cm (18.99 in) with
rack latches