![EMC2 EMC VNX5400 Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/emc2/emc-vnx5400/emc-vnx5400_hardware-information-manual_2399831021.webp)
System component description
EMC VNX5400 Hardware Information Guide
21
Data Mover enclosure front view
The front of the File/Unified VNX5400 platform 2U Data Mover enclosure (DME) contains
two enclosure status LEDs (power and fault) as shown in
Note:
is a graphical representation of the File/Unified VNX5400 platform 2U Data
Mover enclosure with four power supply/cooling (fan) modules and two CPU modules
installed.
Figure 7 Data Mover enclosure status LEDs
describes the 2U Data Mover enclosure status (power and fault) LEDs.
AC
AC
AC
AC
Data Mover enclosure
fault LED
Data Mover enclosure
power LED
CNS-001667
Table 5 DME status LEDs
LED
Color
State
Description
Power
Blue
On
Data Mover enclosure is powered up, operating normally
—
Off
Data Mover enclosure is powered down.
Fault
Amber
On
A replaceable component failed within the enclosure.
Note: When the enclosure fault LED is amber, look for the
replaceable component within the enclosure that is causing
the fault. Refer to the other status LED definitions in this
section to determine which replaceable component failed.
—
Off
Data Mover enclosure operating normally.