EMC® VNX5300™ Hardware Information Guide
32
EMC® VNX5300™ Hardware Information Guide
SP I/O module slots
There are two SP PCI Gen 2 x4 I/O module slots. These slots support the following
I/O modules (
◆
Two-port 10-Gb/s optical or active Twinax (w/iSCSI protocol)
◆
Four-port 1-Gb/s 10/100/1000 copper iSCSI
◆
Four-port 8-Gb/s optical Fibre Channel (running at 2, 4, or 8-Gb/s)
◆
Two-port 10-Gb/s optical or active Twinax Fibre Channel over Ethernet (FCoE)
Figure 29
Example of SP with a Fibre Channel (FC) I/O module and an iSCSI I/O module
For a full description of the I/O module types used in the SP, go to
Control Station rear
view
On the rear, viewing from left to right, the Block and File VNX5300 platform Control
Station includes the following hardware components:
◆
AC power in connector
◆
Two PS/2 connectors (keyboard and mouse)—not used
◆
One (DB-9 plug) serial modem connector
◆
One (DB-15) video (VGA socket) connector—not used
◆
Four (RJ-45) NIC (labeled A, CS, B, and MGMT) connectors
5
GND
Ground
6
DSR
Data set ready
7
RTS
Clear to send
8
CTS
Request to send
9
RI
Ring indicator
Table 20
Serial RS-232/EIA 232 (micro DB-9) connector (socket) pinout (continued)
DB-9 Pin
Signal
Description
X4
2
3
4
5
6Gb
SAS
8Gb
fibre
1
0 X4
6Gb SAS
Cover
Do not remove
Cover
Do not remove
SP I/O Module Slots
VNX-000286