System component description
15
EMC® VNX5300™ Hardware Information Guide
DME front view
The front of the Block and File VNX5300 platform, the DME contains two enclosure
status (power and fault) LEDs (
).
describes the DME power and fault
LEDs.
Note:
is a graphical representation of the Block and File VNX5300 platform DME with
four power supply/cooling (fan) modules and two CPU modules installed.
Figure 8
Data Mover enclosure LEDs
CPU LEDs
The CPU modules in the DME contain the power, fault, and unsafe-to-remove LEDs.
shows the CPU LEDs and
describes them.
Figure 9
CPU LEDs
AC
AC
AC
AC
Data Mover Enclosure
fault LED
Data Mover Enclosure
power LED
CNS-001667
Table 6
Data Mover Enclosure LEDs
LED
Color
State
Description
Power
Blue
On
DME is powered up and all the FRUs in the enclosure are operating
properly
—
Off
DME is powered down.
Fault
Amber
On
A FRU failed within the enclosure.
—
Off
DME operating normally.
AC
AC
AC
AC
CPU power LED
CPU fault LED
CPU unsafe to
remove LED
CNS-001669