 SVR-I1U-1208 Server Installation and

Maintenance Guide

P/N 300-013-549
REV 02

June, 2013

This document describes installation and maintenance procedures for the SVR-I1U-1208
server. This server has slots for eight 2.5-inch drive assemblies. Some server components
are replaceable as field replaceable units (FRUs). Refer to your product documentation for
information on which components are FRUs. Before attempting to perform hardware service
procedures, review your service contract because replacement of some server components
by unauthorized personnel may void service warranties.
Topics include:

u

Technical information and requirements

.................................................................... 2

u

Installing the server in a cabinet

.................................................................................3

u

Maintaining the server

............................................................................................. 14

u

Replacing a disk drive assembly

.............................................................................. 15

u

Replacing a power supply module

............................................................................18

u

Replacing the server

.................................................................................................19

u

Removing the slide rails from the cabinet

.................................................................28

Содержание SVR-I1U-1208

Страница 1: ...product documentation for information on which components are FRUs Before attempting to perform hardware service procedures review your service contract because replacement of some server components...

Страница 2: ...tion Requirement Description AC line voltage 90 264 V AC autoranging 47 63 Hz Power consumption operating maximum 900 VA 883 W maximum fully configured Heat dissipation 31 80 x 105 J hr 3015 BTU hr ma...

Страница 3: ...feet the maximum operating temperature is de rated 1 F 550 ft Shipping and storage requirements Table 4 Shipping and storage requirements Requirement Description Ambient temperature 40 C to 65 C 40 F...

Страница 4: ...inet should have its own switchable power distribution We suggest that you use a cabinet that has dual power distribution units one on each side We recommend that you use cabinet anti tip devices espe...

Страница 5: ...ips pan head 8 32 x 0 35 in screws Stabilize the server and rail mounting 1U bezel application specific CL4887 Covers front of server in cabinet You need a 2 Phillips head screwdriver to complete the...

Страница 6: ...the rail end and hold the tab in 3 Rotate the alignment post assembly either clockwise to switch from round posts to square posts or counter clockwise to switch from square posts to round posts until...

Страница 7: ...883 3 1 2 Attaching the inner rails to the server Attach an inner rail to each side of the server by performing the procedure that follows for each rail Refer to Figure 3 on page 8 while performing th...

Страница 8: ...ontains a right and a left slide rail Install each slide rail in the cabinet using the procedure that follows Procedure 1 From the front of the cabinet align rail alignment posts with the rear channel...

Страница 9: ...go securely into the holes on the front channel Figure 5 on page 9 An audible click indicates that the connection is secure Figure 5 Inserting rail alignment posts into front channel holes CL5091 3 S...

Страница 10: ...rt werden Zur Vermeidung von k rperlichen Verletzungen und oder der Besch digung des Ger tes bitte das Geh use nicht ohne die Hilfe einer zweiten Person anheben und einbauen Il contenitore pesante e d...

Страница 11: ...ty Figure 8 on page 11 shows the inner rail without the server attached Figure 8 Aligning the inner rail with white plastic guide block CL5093 3 Slide the server into the cabinet so the inner rails ex...

Страница 12: ...slide rails are engaged and locked 5 On the outside of each rail assembly slide the blue disconnect tab forward to unlock the server and push the server completely into the cabinet Figure 10 on page...

Страница 13: ...ation specific and may not appear as shown Bezels may include a key lock All bezels include two tabs on either side that you press in to release the bezel and its latches Refer to Figure 12 on page 13...

Страница 14: ...ailable When you replace FRUs you can inadvertently damage the sensitive electronic circuits in the equipment by simply touching them Electrostatic charge ESD that has accumulated on your body dischar...

Страница 15: ...ay without a disk drive assembly or device installed must be occupied by filler module If a disk drive assembly is not hot swappable you may lose data when your replace a disk drive assembly while the...

Страница 16: ...zel The front of the server may be covered by a bezel Bezels are application specific and may not appear as shown Bezels may include a key lock If the server has a bezel remove it Refer to Figure 13 o...

Страница 17: ...ver begins to close by itself push on the lever to lock it into place Figure 15 Installing the replacement disk drive assembly CL5277 5 Remove and store the ESD wristband Reinstalling the bezel If a b...

Страница 18: ...ing clip securing the module s AC power cord and unplug the cord 3 Push the green latch on the faulted power supply module to the left while pulling the supply out of the server by its handle Figure 1...

Страница 19: ...s section describes how to perform each task 1 Power off the server 2 Disconnect the cables from the server 3 Remove the bezel from the server 4 Remove the server from the cabinet 5 Remove the inner r...

Страница 20: ...Bezels are application specific and may not appear as shown Bezels may include a key lock If the server has a bezel remove it Refer to Figure 19 on page 20 while performing the procedure that follows...

Страница 21: ...und oder der Besch digung des Ger tes bitte das Geh use nicht ohne die Hilfe einer zweiten Person anheben und einbauen Il contenitore pesante e dev essere installato nel rack da due persone Per evita...

Страница 22: ...server 4 Being prepared to support the full weight of the server slowly pull the server forward and remove it from the cabinet Figure 22 on page 22 Figure 22 Releasing the inner rail locks and removin...

Страница 23: ...er rails from the server CL4972 1 2 Unpacking a part Procedure 1 Attach an ESD wristband to your wrist and the enclosure in which you are installing the part 2 Unpack the part and place it on a static...

Страница 24: ...studs on the server and push the inner rail onto the connection studs 2 Slide the inner rail forward along the server until the studs fit securely into the small end of the rail notches An audible cli...

Страница 25: ...weiten Person anheben und einbauen Il contenitore pesante e dev essere installato nel rack da due persone Per evitare danni personali e o all apparecchiatura non tentare di sollevare ed installare in...

Страница 26: ...ail without the server attached Figure 27 Inner rail over the first part of ball bearing retainer assembly CL5094 4 Once the inner rails are properly engaged with the ball bearing retainer assemblies...

Страница 27: ...that you removed from the original server into the back of the replacement server Reinstalling the bezel If a bezel covered the front of the server reinstall the bezel using the procedure that follow...

Страница 28: ...ure that follows Procedure 1 On each rail remove the small stabilizer screw that secures the rail to the rear channel Figure 31 on page 28 Figure 31 Removing the rear stabilizing screws CL4854 2 Relea...

Страница 29: ...Figure 32 Releasing the rail from the cabinet channels CL4856 Rear A B Removing the slide rails from the cabinet 29...

Страница 30: ...rchantability or fitness for a particular purpose Use copying and distribution of any EMC software described in this publication requires an applicable software license EMC EMC and the EMC logo are re...

Отзывы: