background image

   

                                                                 

 

POWERJET MANUAL

 

8f749dd9-8865-44fd-baed-1b68166d2198file.doc 

                               

             

POWERJET OWNERS INSTALL & OPERATE MANUAL

 

24 

24 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Notice 

The contents of this manual are subject to change without notice.  Portions of this document may have been updated.  
The Manufacturer reserves the right to make equipment changes and improvements which may not be reflected in this document.  
 
We recommend that this document be read in its entirety before any attempt is made to operate the equipment. 
 
Copyright © 2000-2016       Equipment Mfg. Corp.        Printed in U.S.A.    All Rights Reserved 

 

WARNING 

 

HOT !  ALLOW TO COOL BEFORE 

HANDLING MACHINE OR CONTENTS. 

 

THIS MACHINE IS INTENDED 

TO PROCESS WATER ONLY. 

USER IS SOLELY LIABLE FOR 

SUITABILITY OF OTHER LIQUIDS. 

 

USE ONLY NON-FLAMMABLE, 

NON-TOXIC, WATER SOLUTION 

COMPATIBLE WITH OPERATION 

& MATERIALS OF CONSTRUCTION 

CAUTION ! 

 

Please  completely  read  and  review  this  manual  before  installation 
and start-up of the system. 

 

The 

EMC

 

®

 

POWERJET

 

®

 is designed for use with 

water-based, Non-Flammable fluids only !

 

 

The user is responsible for determining the applicability of their fluid 
with the materials of construction and function of this unit. 

 

A  Qualified  Gas  Technician  should  perform  the  installation  and  the 
initial startup and calibration of the GAS Burner assembly, if the unit 
is so equipped. 

 

Failure  to  follow  cautions  and  operating  procedures  contained  in 
this manual may void the warranty and could lead to dangerous and 
unsafe conditions. 

WARNING ! 

 

Always disconnect Electrical and Gas utilities prior to servicing 

the  

EMC

 

® 

 

POWERJET

 

®

  parts washer. 

Electrical Approval Conditions: 

1.  Not Suitable for Hazardous / Classified Areas 
2.  This device shall only be installed, maintained and used by authorized and qualified personnel. 
3.  This equipment shall be permanently grounded in accordance with the National Electrical Code. 
4.  The final installation of this system shall comply with all the local and national codes. 
5.  This device is only evaluated for fire and shock hazard, its performance and accuracy have not been investigated. 

Содержание POWERJET

Страница 1: ...ECTION and USE of the EMC POWERJET PARTS WASHER and SAVE FOR FUTURE REFERENCE Standard Models 2846E 4046E 5846E And Option Models 4046G 5846G 2846E SS 4046E SS 5846E SS 4046G SS 5846G SS OWNER s MANUA...

Страница 2: ...m The EMC POWERJET is designed for use with water based Non Flammable fluids only The user is responsible for determining the applicability of their fluid with the materials of construction and functi...

Страница 3: ...from the pallet until Ready to Install the unit If there is any damage the following policy and procedures apply D Damaged Merchandise Freight Claims When the product is shipped from EMC it is new un...

Страница 4: ...B Basic Frame Height C Floor to Top of TurnTable Shelf Adjustable D Depth Front to Rear E Door Swing Clearance F Foot Pad Width Side to Side G Total Width Side to Side V Vent Stack Inside Diameter 28...

Страница 5: ...ssis of the washer IMPORTANT The chassis of this washer MUST be Properly Grounded B THREE PHASE HEATER HOOKUP These Washers have 3 or more Immersion Heaters Each Heater draws approximately 18 amps eac...

Страница 6: ...ve Therefore carbon steel Parts Washers are designed for use with water and soap with rust inhibitors The rust inhibitors not only protect the washer cabinet but also the customers steel and iron item...

Страница 7: ...ifold To Turn Table Lowest position D Top Rotor Bar To Turn Table Lowest position E Manifolds Side to Side F Rotor Bars Side to Side G Floor to Turn Table top Lowest position 2846 46 44 42 40 28 25 23...

Страница 8: ...the proper parts baskets or racks or fixtures as needed to hold or contain loose or small parts 2 Set the Wash Cycle Timer It is the 30 Minute Timer Knob and Indicator Light located at the upper front...

Страница 9: ...and volume of activity the Soap Water solution in your washer will need to be changed from time to time In some cases this can be every week or twice a month or once a month or even less often but in...

Страница 10: ...le Next you will need to DRAIN some of your wash water solution from the Tank down to a level BELOW the Pump Casing PUMP CASING VOLUTE 3 Remove Drip Cover 2 screws and small plastic end cap 4 Remove I...

Страница 11: ...stallation Protect the faces Install both the seat and rotary square to the shaft Check stationary seat installation from behind seat cavity for squareness STATIONARY SEAT Clean seal cavity in pump ad...

Страница 12: ...STAT 7 DAY TIMER TO TURNTABLE MOTOR PUMP CONTACTOR HEATER CONTACTOR 30 20 10 Turn Past 0FF MINUTES OFF 2 2 0 1 2 0 1 6 0 200 1 8 0 1 4 0 10 0 AC POWER IN 220V 3 40A Ground to chassis Control Box Front...

Страница 13: ...h of a different color connect to the bottom right side main terminal of the Heater Contactor Single Phase Power LINE IN WIRING GROUND connection is to the chassis same as the Three Phase hook up LINE...

Страница 14: ...HEATER CONTACTOR Control Box Front View Control Box Rear View Control Box Side View cover removed AC POWER IN 440V 3 20A Ground to chassis Electric models 2846E 4046E 1 5HP 440V 3ph 20A Heater Box Cov...

Страница 15: ...Relay HEATER CONTACTOR TO TURNTABLE MOTOR AC POWER IN 220V 3 40A Ground to chassis Control Box Front View Control Box Rear View Control Box Side View cover removed Electric models 2846E 4046E 5HP 220V...

Страница 16: ...MOTOR AC POWER IN 440V 3 20A Ground to chassis Control Box Front View Control Box Rear View Control Box Side View cover removed Electric models 2846E 4046E 5HP 440V 3ph 20A Thermostat Probe in sleeve...

Страница 17: ...R IN 220V 3 80A Ground to chassis Control Box Front View Control Box Rear View Control Box Side View cover removed Electric models 5846E 5HP 220V 3ph 80A To Pump Contactor Power In Heater Box Cover cu...

Страница 18: ...PUMP CONTACTOR Over Load Relay TO TURNTABLE MOTOR AC POWER IN 440V 3 40A Ground to chassis Copper Capillary Tubing Control Box Front View Control Box Rear View Electric models 5846E 5HP 440V 3ph 40A T...

Страница 19: ...HEATER CONTACTOR PUMP CONTACTOR Over Load Relay TO TURNTABLE MOTOR AC POWER IN 220V 3 20A Ground to chassis white wire black wire white wire black wire Control Box Front View Control Box Rear View GAS...

Страница 20: ...Pulley on model 4046 and larger since March 2015 begin s n9296215 PJ126 SPINDLE NUT taller nut PJ127 ROLLER BEARING CONE CUP ASSEMBLY PJ128 STAND OFF SHIMS under Bearing 2 pieces PJ129 SPINDLE SEAL I...

Страница 21: ...hermostat KNOB degrees numbered dial knob 1 STANDARD PUMP MOTOR ITEMS PSK300 PUMP SEAL KIT includes 2 Seals with 2 Lube packs and 1 O Ring PJ301 1ph Std Pump MOTOR 220V 1 phase 1 HP 56J ODP 25 PJ301 3...

Страница 22: ...07 001 IGNITION TRANSFORMER 7300V 5 60186 004 24 Volt TRANSFORMER 2 63263 005 Pressure Vacuum SWITCH 2 diam Black White plastic disk 1 Clear Hose for above switch x 9 Length 1 100968 002 Hose Barbed F...

Страница 23: ...or and Manifold Drive Belt slipping on Pulley Belt DriveMotor Not functioning Check for Loose Parts sticking out Adjust Drive Belt tension Replace Belt DriveMotor GearMotor Leaking around cabinet or w...

Страница 24: ...em The EMC POWERJET is designed for use with water based Non Flammable fluids only The user is responsible for determining the applicability of their fluid with the materials of construction and funct...

Страница 25: ...y outlined above are exclusive and total liability of EMC or its Distributor with respect to this sale or the equipment and service furnished hereunder in connection with the performance or breach the...