42
Table
10.4.1
10.4 MOTOR PROTECTION
Compressors are protected against overheating by the conventional inherent internal line break motor
protection, mounted on the motor windings.
The OLP (Overload protector) detects unusual motor temperature rise and/or abnormal high current
input. The OLP trip is influenced by several factors - working conditions, suction gas density/
temperature, supply voltage, etc.
10.5 DEGREE OF PROTECTION
The degree of protection provided by the terminal cover and CSR box supplied with the compressor is IP21, where:
2 – protected against solid objects over 12.5 mm (fingers or similar)
1 – protected against vertically falling drops of water or condensation
10.4.1 OVERLOAD PROTECTOR PARAMETERS
MODEL
PHASE
DISC TEMPERATURE °C
TIME CHECK
(A)
RESET TIME
(SEC)
OPEN (±5 °C)
CLOSE (±9 °C)
SE6015GK-SE6021GK
Single phase
105
61
65
2~10
SE2006GK-SE2010GK
SE6026GK-SE6030GK
Single phase
115
61
78
2~10
SE2012GK-SE2014GK
SE6015GS
Three phase
115
60
25
3~10
SE2006GS-SE2008GS
SE6018GS-SE6021GS
Three phase
120
60
32
3~10
SE2010GS
SE6026GS-SE6030GS
Three phase
120
60
42
3~10
SE2012GS-SE2014GS
SE6036GS
Three phase
145
60
41
3~10
SE2017GS
SE6043GS
Three phase
140
60
52
3~10
SE2020GS
SE6053GS-SE6067GS
Three phase
140
70
78
3~10
SE6078GS-SE6089GS
Three phase
120
60 ± 10
90
3~10
SE2023GS-O
Three phase
140
60
52
3~10
SE2028GS-O
Three phase
140
70
78
3~10
SE2031GS-O
Three phase
140
70
78
3~10
SE2039GS-O
Three phase
120
60 ± 10
90
3~10
Содержание Scroll SE2006GK-C
Страница 1: ...FOR EMBRACO SCROLL REFRIGERATION COMPRESSORS SCROLL INSTALLATION INSTRUCTIONS...
Страница 2: ...2...