Страница 1: ...User manual PATENTS GRANTED AND PATENTS PENDING V10 Emberstrip 8AV With Bluetooth Smart Sensor ESUSAV8 ET 10B ...

Страница 2: ...convenient location that is in line of sight Close to your television is the best position and within normal operation of your existing remote control s The Bluetooth Smart Sensor detects use of any of your remote controls to know when you are using your AV equipment 5 Plug the Embertec Emberstrip 8AV into the wall outlet 6 Power is now applied to the Power Saving sockets The LED monitoring light ...

Страница 3: ...it s not convenient you can delay the switch off with emberconnect Easily control Active Powerdown settings to suit your lifestyle Set the time before your Embertec Emberstrip 8AV saves you money by switching off power to unused AV equipment connected to the Power Saving sockets to 1 or 2 hours Easily enable BedroomMode Set the brightness and flash duration for minimum disturbance in a bedroom Eas...

Страница 4: ...dby light has switched on Turning OFF your AV equipment Simply turn your equipment off in the normal way The Embertec Emberstrip 8AV will then remove power from the Power Saving sockets after a delay of approximately 1 minute NOTE The LED light on the Bluetooth Smart Sensor will flash for about 60 seconds to warn you that power is about to be removed from the AV Power Saving sockets Active Powerdo...

Страница 5: ...tion guide 4 Using your Audio Visual equipment 7 with the Embertec Emberstrip 8AV What you need to know 8 Connecting your mobile device 10 MusicMode settings 12 BedroomMode settings 13 Fast facts 14 Specifications and compliance 15 Troubleshooting guide 17 Warranty 18 5 ...

Страница 6: ...rip 8AV 1 Embertec Emberstrip 8AV 2 Bluetooth Smart Sensor 3 On Off Power Saving sockets indicator light 4 Power Saving sockets 5 Always On sockets 6 Overload protection Reset Button 7 Surge protection light 1 6 5 4 7 3 2 6 ...

Страница 7: ...luetooth Smart Sensor The Infrared Bluetooth Smart Sensor activates the Power Saving sockets monitors activity and is also used to set the Active Powerdown It comes with a 9 8 ft 3 m cable LED light and two button control It can also be controlled via your Android iOS mobile device by downloading and installing the emberconnect app Status lights The Protected light should be on If this light turns...

Страница 8: ...t Ensure cords plugged into the Embertec Emberstrip 8AV remain tangle free It is recommended to regularly inspect the Embertec Emberstrip 8AV for damage The Embertec Emberstrip 8AV must not be used if it shows any signs of damage This Embertec Emberstrip 8AV is for indoor use only Do not use outdoors Do not use this Embertec Emberstrip 8AV for anything other than its intended use Misuse may cause ...

Страница 9: ... can be permanently set to 2 hours or temporarily 8 hours MusicMode When will Active Powerdown switch the Audio Visual AV equipment off If your Embertec Emberstrip 8AV detects that your Audio Visual AV equipment is on but has not been used for a period of 1 2 or 8 hours depending on your settings the LED light on the Bluetooth Smart Sensor will flash for approximately 10 minutes to warn you that p...

Страница 10: ...ately 3 seconds for it to be ready 4 Press and HOLD the MUSIC button on top of the sensor for 3 seconds The LED on the front of the sensor will start flashing quickly for 1 minute 5 The Bluetooth Smart Sensor is now ready to pair with your mobile device 6 In the emberconnect app press the button to start the pairing process 7 A dialog box will appear after a few seconds you should now type the pai...

Страница 11: ... your home s energy savings Follow these instructions to change Active Powerdown to 2 hours this may be preferred for longer movies or programs where remote control activity is less frequent NOTE Make sure your AV System is on before you start changing settings To set the Active Powerdown timer simply press the SET button on top of the sensor The 1 and 2 LED lights on top of the sensor will light ...

Страница 12: ...hese settings can easily be changed by using the emberconnect app Remember 1 In this mode your system will stay on for 8 hours unless you switch your appliances off 2 Your permanent Active Powerdown timer setting will revert to 1 or 2 hours once you have switched your appliances off or after 8 hours whichever comes first NOTE Make sure your AV System is on before you start changing settings Ensure...

Страница 13: ...ake sure that at least your TV is switched on before starting 1 Press and hold the SET button on the Bluetooth Smart Sensor for 3 seconds then release The LED light on the front of the sensor will flash starting from a faint flash slowly progressing to a bright flash 2 When you are happy with the level of brightness press the SET button on the Bluetooth Smart Sensor again 3 You can change the brig...

Страница 14: ...th a safety device that removes power in the event of overloading Should this occur turn off and unplug all units and press the reset button Then plug into the wall socket again Once reset use any remote control to activate power to the Power Saving socket Connect one device at a time If any of the devices cause the safety device to trip again then get the offending device serviced If the Embertec...

Страница 15: ... operating 95 RH at 122 F 50 C Protection and Safety Surge Compliance UL 1449 Powerstrip Safety Underwriters Laboratories Tested and Listed to UL 1449 and UL 1363 Total Surge 1 530 Joules 39 000 Amps for all outlets Input Current 15 Amps RMS via circuit breaker Over Current Threshold 15 Amps RMS Electrical Durability Relay Endurance Over 100 000 switching cycles Operating Voltage 110 V AC 10 Maxim...

Страница 16: ... instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measur...

Страница 17: ...aybe interfering with the Embertec Emberstrip 8AV such as compact fluorescent lights computers mobile phones and other portable consumer electronic devices If possible relocate these interfering devices Move the Bluetooth Smart Sensor to another location that is within line of sight and normal operation range of your Audio Visual AV equipment remote controls The Protected LED on the main body of t...

Страница 18: ......

Страница 19: ......

Страница 20: ...cept as required by law Embertec is not responsible for special incidental or consequential damages or loss of data or any loss or damage arising from intentional misuse of the product Such damages and loss include but are not limited to lost business business downtime component equipment replacement and reconfiguration and the costs of retrieval of lost data Embertec Emberstrip and the Embertec E...