INSTALLATION OF NATURAL GAS PILOT VALVE (cont.) 

E.    Connect the two 3/8" Street Elbows (Part #16). Screw  the 3/8" 

 

threads of the first elbo

 

w into the outlet of 

Place the hole of the Heat Shield (Part #14) over the elbow and slide it down against the body of the elbow 

 

 Apply pipe compound to the male threads of the elbow and attach it to the control valve outlet. 

 

(See Figure 5)

F. 

Attach the 3/8" Natural Gas Orifice (Part #18 or #19) through th

e Burner Pan to the Burner Bar using 

 

the 3/8" Locknut (Part #15, only with Dual Burner log sets). When installing a single burner log 

 

set, a 3/8" locknut is not used. Be sure the small drill hole on the 3/8" Natural Gas Orifice is facing 

 

the gas control valve and the large hole is facing the burner pan. 

G. 

   

Using pipe compound, connect the  Street Elbow (Part #16, attached to the valve assembly) to the Burner

 

Orifice (part #18 or #19) on the 3/8" NPT threads.  

 

 

H.   

The valve assembly can be rotated to horizontal, a

nd to allow it to rest on the fireplace floor. Simply rotate 

the entire valve assembly 

 

by turning the 3/8" Street Elbow (connected to burner orifice) with a wrench. 

(See Figure 5)

I.    Attach Pilot Burner Assembly (Part #7) to the Pilot Bracket (Part #8) using the two machine screws (Part #10) 

 

and two nuts (Part #11). See Figure 1A on the previous page. Carefully bend the Pilot tubing (Part #6) when 

 

attaching the Pilot Burner Assembly to the Burner Pan. Care should be taken not to kink the tubing which 

 

would restrict gas flow to the Pilot Burne

r.

 

NOTE:

 

The Pilot Bracket utilizes four mounting hol

es for adjustment of the Pilot Burner  Assembly should 

 

your installation require repositioning. Repositioning of the Pilot Burner 

 

Assembly may be necessary if the log set is experiencing intermittent 

 

shutdown. Shutdown is caused by overheating of the Pilot Burner 

 

Assembly by the main burner flame. If shut down is

 occurring, move 

 

the Pilot Burner Assembly over to the next mounting hole so that only 

 

the tips of the Pilot Burner Assembly are hanging over the Burner Pan. 

 

Only one Mounting Screw (Part #10) will be used in this application.

J.   Place the assembled Burner Pan with the Gas Control Valve in the 

 

center of the fireplace.

K.   

Connect the 1/2" gas supply line from the fireplace 

to the 3/8" Straight 

 

Flared fitting (Part #4) with the 3/8" Flared

 

T

ubing supplied with the gas 

 

log set. Refer to the General Installation Instructions section titled 

 

“Connecting Gas Supply to Burner Pan” for full instructions.

L.   

T

est connections for leaks with soapy water. Retighten if necessary, 

 

and retest the connections to determine if any other leaks are present.

M.   Refer the General Installation Instructions for Granule, Ember, Grate 
 

and Log placement.

Figure 5

Figure 3

Figure 4

              SINGLE & DUAL SYSTEMS

 

Outlet

  Inlet

Thermocouple 

   

Connection

Pilot Fitting

Connection

 

Plug

the second.

 

IMPORTANT: Be sure to turn the pilot adjustment  screw with a screwdriver two full turns in a 

 

counter-clockwise

 

 

direction to enable pilot operation. 

(See Figure 4)

at the point it enters the Gas Control Valve. Line up the mounting holes with the threaded holes in the Gas

Valve. Install the (2) 10 x 24 Heat Shield mounting screws (Part #13) and tighten them at this time.

Gas Control

Knob

Pilot

BAdjustment Screw

Knob Position

    Indicator

Burner Pan

Street Elbows

Gas Control Valve

 

             

 

 

Part # 4

Содержание RVS304

Страница 1: ...ilot Valve on all LP Pro pane applications These regulations MUST be followed on all installations of this type 1 2 3 6 Part No Description 4 5 7 8 Part No Part No Description Description Remote Trans...

Страница 2: ...Install sheet metal screw into top left hole of the bracket See Figure 1 C Attach the 3 8 straight Flared Fitting Part 4 to the IN position of the Gas Control Valve using pipe joint compound See figur...

Страница 3: ...nt of the Pilot Burner Assembly should your installation require repositioning Repositioning of the Pilot Burner Assembly may be necessary if the log set is experiencing intermittent shutdown Shutdown...

Страница 4: ...it must drop out before the lighting sequence can begin again This may take as much as 3 minutes 2 To relight the pilot follow the steps in the Pilot Gas and Lighting Procedure section and hold in for...

Страница 5: ...S ON OFF 1 This turns the appliance on or off H M L 2 This controls the height of the ame It has three levels IMPORTANT THE REMOTE RECEIVER SHOULD BE POSITIONED WHERE AMBIENT TEMPERATURES DO NOT EXCEE...

Страница 6: ...ON OFF button is pressed the THERMISTOR resets itself and the replace will begin operating gain However the beep ing will continue if the ambient temperature remains between 120 F and 130 F This beep...

Страница 7: ...gas ow Thermocouple too tight or has bad connection Check all valves Clear obstructions Check for line kinks 3 Pilot Burner go out after burning for several minutes up to one hour Overheating of Ther...