background image

MODEL RVS304

Supplemental Installation Instructions for use with 

                    Natural Gas Log Sets

NOTE:

 

This kit is for both Natural Gas and LP Gas applications. For LP (Propane) Gas

         installation, see additionall LP instructions packaged with necessary hardware.

DO NOT USE THE NATURAL GAS ORIFICE SUPPLIED WITH THIS KIT ON LP 

         

(PROP ANE) GAS INSTALLATIONS! IMPROPER COMBUSTION WILL OCCUR!

                                           

IMPORTANT:

Read and follow ALL instructions carefully, as these supplemental Remote Controlled

Pilot Assembly instructions are to be used in conjunction with the General Installation 

Instructions supplied with all  Vented Natural Gas Log Sets. 

National code Requirements mandate the use of a Safety Pilot Valve on all LP (Pro-

pane applications. These regulations MUST be followed on all installations of this type.

1

 

 

2

 

 

3

6    

 

Part

No.

Description

4
5

7
8

Part

No.

Part

No.

Description

Description

Remote Transmitter
Remote Receiver & Hardware
Gas Control Valve
Straight Flare Fitting, 3/8”
Thermocouple lead connection

Pilot Line Connection
Pilot Burner Assembly
Pilot Bracket

9

10
11
12
13
14
15
16

Sheet Metal Screw (1)
Machine Screw (2)
Nut (2)
Pilot Orifice Location (NG)

Heat Shield

Machine Screw 10 x 24 (2)

Lock Nut (3/8 NPT)
Street Elbow, 90 deg. (2)

17

18

Heat Shield, Receiver

18” Natural Gas Orifice

   (Small Center Hole)

24” Natural Gas Orifice

   (Large Center Hole)

19

20

Battery, 

ransmitter 12v 

21

Battery, T

Receiver  AA (3)

REMOTE CONTROLLED SAFETY PILOT KIT

22

Thread Sealant

1

2

3

7

8

21

20

22

LP Conversion

Items

LP Burner Media

14

5

6

15

4

18

19

16

17

9

11

13

10

 

Illustrated Parts List

12

Содержание RVS304

Страница 1: ...ilot Valve on all LP Pro pane applications These regulations MUST be followed on all installations of this type 1 2 3 6 Part No Description 4 5 7 8 Part No Part No Description Description Remote Trans...

Страница 2: ...Install sheet metal screw into top left hole of the bracket See Figure 1 C Attach the 3 8 straight Flared Fitting Part 4 to the IN position of the Gas Control Valve using pipe joint compound See figur...

Страница 3: ...nt of the Pilot Burner Assembly should your installation require repositioning Repositioning of the Pilot Burner Assembly may be necessary if the log set is experiencing intermittent shutdown Shutdown...

Страница 4: ...it must drop out before the lighting sequence can begin again This may take as much as 3 minutes 2 To relight the pilot follow the steps in the Pilot Gas and Lighting Procedure section and hold in for...

Страница 5: ...S ON OFF 1 This turns the appliance on or off H M L 2 This controls the height of the ame It has three levels IMPORTANT THE REMOTE RECEIVER SHOULD BE POSITIONED WHERE AMBIENT TEMPERATURES DO NOT EXCEE...

Страница 6: ...ON OFF button is pressed the THERMISTOR resets itself and the replace will begin operating gain However the beep ing will continue if the ambient temperature remains between 120 F and 130 F This beep...

Страница 7: ...gas ow Thermocouple too tight or has bad connection Check all valves Clear obstructions Check for line kinks 3 Pilot Burner go out after burning for several minutes up to one hour Overheating of Ther...

Страница 8: ...0062 Goods returned improperly packaged are the sole responsibility of purchaser It is agreed that any repair or replacement is the exclusive remedy from Sure Heat Manufacturing In no case shall Sure...

Отзывы: