EmberGlow MO18NG Скачать руководство пользователя страница 4

— 3 —

1.  This gas log set is only to be installed and burned in a fully vented fireplace with a fully functional damper and 

chimney that is free of any obstructions. The fireplace must be constructed of non-combustible materials and 
approved to burn wood. 

WARNING: Do not burn wood or other material in any fireplace  fitted with a gas 

log set.

2. To operate this gas log set, the fireplace damper must be fully opened and locked.

3.  The smallest or minimum dimension of the chimney flue must be 8 inches in diameter. Do not use an Energy 

Efiicient Gas Log Set if it is smaller than 8 inches. Do not use an Energy Efiicient Gas Log Set if fumes from the 
burner emerge into the room when the damper is fully open. This indicates that there is not adequate draft for our 
log set and the gas log set must not be used until fireplace draft is corrected.

4.  This appliance must be installed with a Damper Stop Clamp (Part #14). When operating this gas log set, the flue 

damper must be fully open. 

WARNING: 

Improper use or installation may cause Carbon Monoxide Poisoning. Carbon Monoxide, which is 

an odorless and colorless gas, is a by-product of combustion. Caution must be taken to insure  the fireplace is 
properly vented when logs are in use. To avoid having potentially dangerous fumes enter the living area, be sure 
the chimney is drawing properly and has sufficient draft.

5.  A fireplace screen must be in place when operating this gas log set. This screen shall have an opening(s) for the 

introduction of combustion air. If the fireplace has glass doors, operate this gas set with the doors fully opened.

6. The nominal inlet gas pressure for this appliance is 7" water column for natural gas.

7.  This gas log appliance and its individual shutoff valve must be disconnected from the gas supply piping system 

during any pressure testing at pressures in excess of 1/2 PSIG.

This appliance must also be disconnected from the gas supply system by closing its individual manual shutoff valve 
during any pressure testing at pressures equal to or less than 1/2 PSIG.

FIREPLACE PREPARATION

A.  Professionally clean chimney and fireplace floor of any  

combustible material to limit the smell from the system.

B.  Open fireplace damper fully and install Damper Stop Clamp  

with 1/4 x 2" set screw (Part #14). This clamp is designed to  
allow any  pilot combustion by-products to vent (See Figure 2.)  
Should the Damper Stop Clamp supplied not fit, a permanent  
damper stop clamp must be installed that will keep the damper  
open at a distance of not less than 1 1/2". Damper must be in  
full open position anytime this unit is in operation.

C.  Prior to connecting the gas log set, make sure that the gas  

supply to the fireplace is completely shut off.

Installation of this Energy Efficient Gas Log Set and provisions for combustion and ventilation air  

must conform with the National Fuel Gas Code ANSI Z21-84 and applicable local codes.

PART NO. 14

Figure 2. Damper stop clamp

Содержание MO18NG

Страница 1: ...set FOR YOUR SAFETY If you smell gas 1 Open windows 2 Don t touch electrical switches 3 Extinguish any open ame 4 Immediately call your gas supplier Do not store or use gasoline or ammable vapors and...

Страница 2: ...SURE HEAT MFG 2008 Complies with ANSI Z21 84...

Страница 3: ...90523 1 WIP 190 90525 1 10 3 4 Burner Support Spacer RMH 120 00420 1 RMH 120 00420 1 RMH 120 00420 1 11 3 8 Brass Ori ce Elbow WIP 120 00350 1 WIP 120 00350 1 WIP 120 0035 1 12 3 8 Locknut RMH 120 009...

Страница 4: ...lace screen must be in place when operating this gas log set This screen shall have an opening s for the introduction of combustion air If the replace has glass doors operate this gas set with the doo...

Страница 5: ...rmine if the replace has a right or left hand gas line feed The circular dimpled hole covering must be knocked out on the appropriate right or left side of the burner pan NOTE Brace pan on workbench w...

Страница 6: ...e no leaks whatsoever turn off gas supply and move to next assembly step GRANULE EMBER AND GRATE PLACEMENT A Spread granules Part 16 over the installed burner pan Granules should be sloped to the same...

Страница 7: ...e the expressed responsibility of the purchaser For repair replacement or service to defective part s please contact our Customer Service Hotline number below Thereafter with valid warranty registrati...

Страница 8: ...SURE HEAT MFG 2008 Complies with ANSI Z21 84...

Отзывы: