Embedded Systems LM5p2-RD Скачать руководство пользователя страница 16

 

Embedded Systems SIA © 2021

 

www.logicmachine.net

 

LM5p2-RD, LM5p2-RDE 

Data sheet / Issue date 26.11.2021  Page 16 / 16

 

 

Quick startup guide 

 

1) Mounting the device on DIN rail 
2) Connect the KNX bus cable 
3) Connect 24V power supply to the device (either through separate 24V crew terminals or 
through Passive 24V DC Power-Over-Ethernet) 
4) Connect Ethernet/LAN cable coming from the PC/switch 

 

 
Default IP configuration 

 

Login name 

admin 

Password 

admin 

IP address 

192.168.0.10 

Network mask 

255.255.255.0 

 
 

Reset device 

 
You can either reboot the device by pressing RESET button or reset the configuration to factory 
defaults: 
 

 

Press and hold for <10 sec

 

 reboot the device 

 

Press and hold for >10 sec

 

 reset networking with IP to factory default 

 

Press and hold for >10 sec and again press and hold for >10 sec

 

 full reset of configuration 

to factory defaults 

 

 

Содержание LM5p2-RD

Страница 1: ...e Serial interfaces and I O ports LM allows to use it as cross standard gateway logic engine visualization platform IP Router Scripting templates provides user friendly flexible configuration interfac...

Страница 2: ...EB SCADA visualization for PC and touch devices cross standard gateway integration with third party devices over USB RS485 serial port Ethernet AV IR HVAC Data logger with trends KNX IP Router Presenc...

Страница 3: ...onnectors or 12V 30V DC Passive Power over Ethernet Power consummation 1 3W Interface KNX EIB TP1 1 DALI master 2 up to 128 DALI ballasts in total EnOcean 868MH with 1 antenna optional 1 Wire 1 10Base...

Страница 4: ...allation and assembly of electrical equipment may only be performed by skilled electrician The devices must not be used in any relation with equipment that supports directly or indirectly human health...

Страница 5: ...ogicmachine net LM5p2 RD LM5p2 RDE Data sheet Issue date 26 11 2021 Page 5 16 Terminal connection schemes Note In first batch of LM5 devices the 24V DC clamp powering ports are placed vice versa rathe...

Страница 6: ...r screw terminals Jumpers up or down passive PoE powering over 24V DC Jumpers down when using active PoE 48V jumpers have to be UP or the product will be damaged Please note that there are two PoE typ...

Страница 7: ...Embedded Systems SIA 2021 www logicmachine net LM5p2 RD LM5p2 RDE Data sheet Issue date 26 11 2021 Page 7 16 Passive PoE switch Passive PoE adapters...

Страница 8: ...Embedded Systems SIA 2021 www logicmachine net LM5p2 RD LM5p2 RDE Data sheet Issue date 26 11 2021 Page 8 16 KNX connection Powering over 24V terminals...

Страница 9: ...irst one is definitive second one is software switchable either it works as RS 485 or as RS 232 If it is set up as full duplex it will operate as RS 232 and respective TX RX GND screw terminals should...

Страница 10: ...heet Issue date 26 11 2021 Page 10 16 RS 485 RS 232 connection If second serial port is set as full duplex in LogicMachine configuration it will operate as RS 232 and respective TX RX GND screw termin...

Страница 11: ...Embedded Systems SIA 2021 www logicmachine net LM5p2 RD LM5p2 RDE Data sheet Issue date 26 11 2021 Page 11 16 Digital output e g relay contactor...

Страница 12: ...Embedded Systems SIA 2021 www logicmachine net LM5p2 RD LM5p2 RDE Data sheet Issue date 26 11 2021 Page 12 16 Digital or Analog input e g pushbutton...

Страница 13: ...Embedded Systems SIA 2021 www logicmachine net LM5p2 RD LM5p2 RDE Data sheet Issue date 26 11 2021 Page 13 16 Analog output 0 10V 4 20mA...

Страница 14: ...Embedded Systems SIA 2021 www logicmachine net LM5p2 RD LM5p2 RDE Data sheet Issue date 26 11 2021 Page 14 16 DALI connection...

Страница 15: ...Embedded Systems SIA 2021 www logicmachine net LM5p2 RD LM5p2 RDE Data sheet Issue date 26 11 2021 Page 15 16 1 wire connection...

Страница 16: ...Ethernet 4 Connect Ethernet LAN cable coming from the PC switch Default IP configuration Login name admin Password admin IP address 192 168 0 10 Network mask 255 255 255 0 Reset device You can either...

Отзывы: