background image

 

 

Assembly of foot extensions 
(only for extraction model)

 

As of a kitchen work surface height in excess of 
850 mm, the foot extensions supplied must be 
assembled. 
To do this, place the device on its side and 
screw out the adjustable feet (they have a 
cross recess on the bottom for a cordless 
screwdriver) Attach the extension panel to the 
housing via the thread holes of the adjustable 
feet using the four hexagon socket screws 
attached. Screw the adjustable feet into 

extension panel.

 

                          

   

Assembly

 

Assemble the control panel in a suitable place 
(cable length: 2 m). The standard control panel 
is attached using two countersunk bolts. To 
enable flush-mount assembly, another control 
panel is an R2 corner radius is included.  
The front plate can be replaced by unscrewing 
the rosettes on the LEDs. 
Place the device below the work surface cut-out. 
Make sure that the front of the device (sticker 
front = filter side) faces towards the cooking 
area. Lift the device into the cut-out by turning 
out the adjustable feet. To set the final height, 
place the cover on the device. Set the height so 
that the cover is flush with the work surface. 
Align the device vertically. 
 

    

 

 
 
 
 
 

 
Kitchen work surfaces which are thinner than 34 
mm can be prevented from sagging by using 
thread screws M4x25 which are screwed into 
the upper frame.  

 

Connect the end of the control panel cable to 
the connector on the control board of the main 
control (control for ventilator). 
The control panel does not have to be 
assembled with remote-controlled models. In 
such cases, the antenna which is secured to the 
back of the housing for transportation, must be 
positioned to ensure a good radio link to the 
portable transmitter. 

 

Electrical connection for extraction mode 

Check 

that the supply voltage corresponds to the 
details on the rating plate. 
For devices between 600 and 800 mm, the 
controls are mounted on the front (filter side). 
The connectors for the mains and ventilator are 
located on the ventilator control.  You require 
two sockets for the power supply.

 

 

 

 

 

 

 

 

 

Содержание Downdraft

Страница 1: ...for EMB DOWNDRAFT EXTRACTOR HOOD as of 08 2016 Assembly and operating instructions ...

Страница 2: ...xtraction mode Page 3 Installation for recirculation mode Page 3 Assembly of foot extensions Page 4 Assembly Page 4 Electrical connection for extraction mode Page 4 Electrical connection for recirculation mode Page 5 Initial operation Page 5 Notes Page 6 Initialisation run Page 6 Maintenance Page 6 No function Page 7 EMB Edelstahl Möbel Beck Brückenstraße 11 74219 Möckmühl Züttlingen Germany Tel 4...

Страница 3: ... together with a gas hob a safety switch is required which only allows the air to be extracted in the upper position Warranty claims cannot be asserted for any damage which results from failure to observe these instructions We reserve the right to make technical changes Before using for the first time Before putting the device into use please note the information below Read the assembly and operat...

Страница 4: ...emaining steam and odours from the air The run on function provides the option of having the fan switch off automatically after 15 minutes The extractor fan features a filter cleaning display which reminds you to clean the filters after 30 hours of service After this operating time the power level display flashes After cleaning the filters the button is pressed until the power level display flashe...

Страница 5: ... authorised specialist Observe the assembly instructions and local installation requirements Before disposing of the packaging material make sure there are no more accessories in the packaging Check the device for transport damage prior to assembly The user must be informed on how to de energise the device if necessary With extraction mode The exhaust air can be guided in all directions the releva...

Страница 6: ...aces towards the cooking area Lift the device into the cut out by turning out the adjustable feet To set the final height place the cover on the device Set the height so that the cover is flush with the work surface Align the device vertically Kitchen work surfaces which are thinner than 34 mm can be prevented from sagging by using thread screws M4x25 which are screwed into the upper frame Connect...

Страница 7: ...hood several times and observe whether the device runs in parallel After aligning the device and using for the first time secure it in a suitable place using the mounting brackets supplied The brackets can be attached to the screws of the device cladding or the screws in the side parts Attach the brackets as far down as possible The top of the device is fixed in place in the work surface cut out a...

Страница 8: ...down the button for a further 10 seconds The system is lowered slightly and lifted up again during initialisation The initialisation run is then complete Please do not let go of the down button during the initialisation run If you let go of this button before the run is complete this process is interrupted and must be started again If the initialisation run is interrupted the system cannot be move...

Отзывы: