Always inspect the compressor before use, and make sure it is in good working condition. Make sure all air 

vents are clear. Check the power cable to make sure it is intact and free from cracks, bare wires etc. Avoid 

using solvents when cleaning plastic parts, most plastics are susceptible to damage from the various types of 

commercial solvents.

Trouble

Possible Cause

Corrective Action

Compressor will not start

1. Blown fuse or circuit breaker 

tripped

1. Replace or reset fuse/circuit breaker

2. Loose electrical connections

2. Check wiring connnections

Low pressure

1. Restricted air filter

1. Replace air filter

2. Defective check valve

2. Replace check valve

3. Air leak in safety valve

3. Check valve by pulling on ring. If 

condition persists, replace valve

Safety valve releases

Defective pressure switch

Replace pressure switch

Pressure in tank falls

1. Air leaks at joints

1. Allow the compressor to build pres-

sure in the tank, to the max pressure if 

possible. Spray or brush soapy water 

on all air connections and look for bub-

bles. Tighten leaky connections. Do not 

over-tighten. 

2. If the problem continues, contact 

customer support for further advice.

Unloader valve leaks when 

pump is not running

Unloader valve seal defective

Allow air in the air tank out until all 

pressure is released. Remove the un-

loader valve plug and clean the valve 

seal. If damaged, replace seal and 

re-install.

Compressor stopped and will 

not re-start

1. Thermal overload protector has 

engaged due to motor overheat-

ing

1. Check that the main supplied 

voltage corresponds to the compres-

sor specifications. An inadequate 

extension cord (too thin or too long) 

can cause the motor to overheat due 

to voltage drop. Excessive use (over 

1 hour continuous) can cause motor 

overheating. Allow the motor to cool 

down.

2. Motor windings burn-out

Contact customer support

Motor does not start and 

makes a humming sound

Capacitor burn-out

Contact customer support

Motor does not start or starts 

slowly

Low voltage electrical supply to 

motor

Check that the main supplied voltage 

corresponds to the compressor speci-

fications. 

 

An inadequate extension cord (too thin 

or too long) can cause the motor to 

overheat due to voltage drop. 

Check power quality at outlet

Compressor runs noisily and 

metallic sounds are heard 

Compressor will not come to 

max pressure

Head gasket or reed valve dam-

aged. 

Stop the compressor and contact cus-

tomer support

Compressor doesn’t provide 

as much air as when new 

and/or cuts off after a much 

shorter time period.

1. Tank has reduced capacity due 

to water retention 

2. Pressure switch is out of adjust-

ment

1. Open drain valve to release water

 

2. Contact customer support

Pump unit does not stop 

when the tank reaches maxi-

mum working pressure.

Defective or pressure switch out 

of adjustment

Stop the compressor immediately (risk 

of explosion) and contact customer 

support

Содержание HULK POWER HP15P005SS

Страница 1: ...nd manufactures products for safe operation However operators and maintenance per sons are responsible for maintaining safety All safety precautions are included to provide a guideline for minimizing...

Страница 2: ...allation 5 Area 5 Electrical Safety 5 Operation 6 Safety Rules 6 Air Tool Cautions 7 Power Source Connection 7 Power Requirements 7 Grounding Instructions 7 Connect to power source 8 Getting Started 8...

Страница 3: ...of excessive pressure build up Safety Valve is preset at factory Do not attempt to make any adjustments to the safety valve Periodically pull the ring on the safety valve end to check that it is work...

Страница 4: ...ic Guidelines 1 Allow only trained authorized persons who have read and understood these operating instructions to use this compressor Failure to follow the instructions procedures and safety precauti...

Страница 5: ...drain valves from freezing NEVER operate compressor with temperatures below 15 F 9 5 C or above 125 F 52 C 2 Allow sufficient space around compressor for maintenance access and adequate airflow Mount...

Страница 6: ...all persons clear of compressor during start up and operation 5 NEVER operate the compressor with the fan coupling or other guards removed 6 DO NOT engage in horseplay with air hoses as death or serio...

Страница 7: ...off Any tool that cannot be controlled with the switch is dangerous and must be repaired 10 Check for damage Check your tool regularly If part of the tool is damaged it should be carefully inspected...

Страница 8: ...that is working properly Pull the ring on the safety valve before each use to make sure the valve is functional Depending on the CFM draw of the tools being operated your new air compressor can be use...

Страница 9: ...ck that the pressure switch is pointed up in the OFF position fig 9 0 3 Ensure that the power supply you are going to use is operating normally 4 Insert the power supply cord into the power supply soc...

Страница 10: ...lose drain valve 3 Pull the ring on the safety valve before each use to make sure the valve is functional 4 Plug the air compressor directly into a 120 volt electrical outlet Do not use an extension c...

Страница 11: ...the un loader valve plug and clean the valve seal If damaged replace seal and re install Compressor stopped and will not re start 1 Thermal overload protector has engaged due to motor overheat ing 1 C...

Страница 12: ...30 Fan cover 2 31 Self tapping screw 4 32 Fan 2 33 Outside spring 2 34 Crank throw 2 35 Sator 1 36 Rotor 1 No Description Qty 37 Bearing 2 38 Outside spring 2 39 Capacitor 1 40 Bolt 2 41 Capacitor cov...

Страница 13: ...13 HP15P005SS man v 170804 Silent Air Series Schematic Drawing...

Страница 14: ...ls Warranty does not apply to defects due directly or indirectly to misuse abuse negligence or accidents repairs or alterations and lack of maintenance HULK shall not be liable for death injuries to p...

Отзывы: