background image

2

EMAX

 

Electric Operated, Piston Compressors

 

Model

 

EP05H080I1

 

EP07H080V1 EP10H120Y1 EP07H080V3 EP10H120Y3

 

Tank 

Type  Horizontal Horizontal Horizontal  Horizontal  Horizontal

 Dimensions 

76 x 30 x 56 

76 x 30 x 56 

78 x 32 x 50 

76 x 30 x 56 

78 x 32 x 50

 

Model

 

EP05V080I1 EP07V080V1 EP10V120Y1 EP07V080V3 EP10V120Y3

 

Tank 

Type Vertical Vertical Vertical  Vertical  Vertical

 

Dimensions

 

34 x 24 x 72 

34 x 24 x 72 

50 x 32 x 78 

34 x 24 x 72 

50 x 32 x 78

 

Tank Size

 

80 Gallon 

80 Gallon 

120 Gallon 

80 Gallon 

120 Gallon

 

Description

 

5HP 7.5HP 10HP 7.5HP 10HP

 

 

Single Phase 

Single Phase 

Single Phase 

Three Phase 

Three Phase

 

SCFM @ 175 psi

 

 

17.0 26.0 35.0  26.0  35.0

 

Max PSI

 

175 175 175  175  175

 

Motor HP

 

5HP 

7.5HP    

10HP    

7.5HP    

10HP   

 

Motor RPM

 

1750 1750 1750  1750  1750

 

Voltage

  208V/230V 208V/230V 208V/230V 

208/230/460/575 

208/230/460/575

 

Pump Model

 APP2I0524T APP4V1043T APP3Y1544T APP4V1043T APP3Y1544T

 

Pump RPM

 

650 640 600  640  600

 

Noise DB(A)

 

73 73 76  73  76

 

Outlet Connection

 

NPT 3/4” 

NPT 3/4” 

NPT 1” 

NPT 3/4” 

NPT 1”

 

Weight 

 (±5 

lbs.) 

715 958 1095 958 1095

 

Shipping Weight

 

800 1043 1242 1043 1242

Contents

 

Page No.

Model Specification Charts

. . . . . . . . . . . . . 2-3

Description

   . . . . . . . . . . . . . . . . . . . . . . . .  3

Safety Information

  . . . . . . . . . . . . . . . . . . .  4

 

Tag Definitions . . . . . . . . . . . . . . . . . . . .  4

 

Basic Guidelines  . . . . . . . . . . . . . . . . . . .  4

 

Breathable Air  . . . . . . . . . . . . . . . . . . . .  4

 

Pressurized Components   . . . . . . . . . . . . .  4

 

Personal Protective Equipment   . . . . . . . . .  4

Inspection 

. . . . . . . . . . . . . . . . . . . . . . . . .  4

 

Forklift Safety   . . . . . . . . . . . . . . . . . . . .  5

 

Lifting Safety  . . . . . . . . . . . . . . . . . . . . .  5

Installation

   . . . . . . . . . . . . . . . . . . . . . . . .  5

 Area 

. . . . . . . . . . . . . . . . . . . . . . . . . . .  5

 

Piping Safety  . . . . . . . . . . . . . . . . . . . . .  5

 

Piping / Tank Installation   . . . . . . . . . . . .  6

 

Electronic Auto Drain 

(if equipped)

  . . . . . .  6

 

Electrical Safety  . . . . . . . . . . . . . . . . . . .  7

 

Wiring Installation  . . . . . . . . . . . . . . . . .  7

 

Page No.

Operation

   . . . . . . . . . . . . . . . . . . . . . . . . .  8

 

Safety Rules   . . . . . . . . . . . . . . . . . . . . .  8

 

Start Up   . . . . . . . . . . . . . . . . . . . . . . . .  9

 

Continuous Run Feature . . . . . . . . . . . . . .  9

Maintenance

   . . . . . . . . . . . . . . . . . . . . . . .  9

 

Safety Steps   . . . . . . . . . . . . . . . . . . . . .  9

 

Belt Adjustment  . . . . . . . . . . . . . . . . . .  10

 

Changing Oil   . . . . . . . . . . . . . . . . . . . .  10

 

Safety Valve   . . . . . . . . . . . . . . . . . . . .  10

 Tank 

. . . . . . . . . . . . . . . . . . . . . . . . . .  10

Maintenance Schedule 

. . . . . . . . . . . . . . . .  11

Troubleshooting

  . . . . . . . . . . . . . . . . . . . .  11

Warranty

   . . . . . . . . . . . . . . . . . . . . . . . . .  12

EMAX Electric Operated, Two-Stage, 5-10 Hp Piston Air Compressors

L•W•H

(inches)

L•W•H

(inches)

Содержание EP05H080I1

Страница 1: ...afe operation However operators and maintenance persons are responsibile for maintaining safety All safety precautions are included to provide a guideline for minimizing the possibility of accidents a...

Страница 2: ...V 208 230 460 575 208 230 460 575 Pump Model APP2I0524T APP4V1043T APP3Y1544T APP4V1043T APP3Y1544T Pump RPM 650 640 600 640 600 Noise DB A 73 73 76 73 76 Outlet Connection NPT 3 4 NPT 3 4 NPT 1 NPT 3...

Страница 3: ...oise DB A 76 76 78 79 Outlet Connection NPT 1 NPT 1 NPT 1 NPT 2 Dimensions 33 x 24 x 73 79 x 32 x 62 72 x 30 x 51 72 x 30 x 51 Weight lbs 1410 1410 1500 1703 Shipping Weight 1512 1512 1609 1810 EMAX E...

Страница 4: ...uct carefully Be thoroughly familiar with the controls and the proper use of the equipment Breathable Air 1 NEVER use air from this compressor for breathable air except in full compliance with OSHA St...

Страница 5: ...mpressor in a clean dry and well lit area Be sure installation area can maintain a temperature range between 35 110 F If ambient temperature drops below 32 F be sure to protect safety relief valves an...

Страница 6: ...njury or death could result 6 Never use reducers in discharge piping Keep all piping and fittings the same size in the piping system 7 For permanent installations of compressed air systems determine t...

Страница 7: ...orized personnel install and maintain this compressor in accordance with all applicable federal state and local codes standards and regulations Follow all NEC National Electric Code standards especial...

Страница 8: ...ustible substances are spilled clean up immediately 8 When checking or adding lubricant or when re filling air line anti icer systems with antifreeze compound shut off compressor and allow it to cool...

Страница 9: ...equipped For heavy use applications such as sandblasting the continuous run feature is available This feature keeps main feed line open to eliminate numerous motor starts stops and to help cool pump...

Страница 10: ...ce all belts with the same brand at the same time Make sure belts are uni matched Do not replace belts independently Figure 12 Safety Valve Pull ring on safety valve before each use TEST ON 0 5 0 5 2...

Страница 11: ...1 Duty cycle exceeded 2 Improper rotation 3 Head valve s not seating properly 4 Blown cylinder head gasket s 5 Restriction in head intercooler or check valve 6 Low oil 7 Dirt in intercooler fins or cy...

Страница 12: ...igation at Purchaser s expense to have a redundant compressor Warranty repairs shall not include freight costs Purchaser is responsible for returning unit to Emax Inc This pump MUST have Emax Inc Lubr...