emaux S700R Скачать руководство пользователя страница 2

2-4

3-4

REPLACEMENT PARTS OF MULTIPORT VALVE 

820

920

Model

A

High

mm

B

Diameter

mm

1020

1130

S800R

S900R

723

920

S700R(B)

Valve Port

Size 

Inch 

Sand 

Kg

2”

2”

2”

355

470

215

2

3

1

4

5

6

7

9

10

11

12

14

16

15

13

17

18

19

20

22

21

24

25

26

23

27

8

REPLACEMENT PARTS OF FILTER

Key

 

No

.

Part

 

No

.

Product

 

Description

 

Qty

1

01013003

Handle

 (

Big

)

1

2

03018008

Pin

 

for

 

Handle

1

3

01181027

Washer

 

for

 

Handle

1

4

01013022

2

.

0

Side

 

Mount

 

Valve

 

Rotundity

 

Lid

 (

Black

)

1

5

89280301

M6

*

32

 

Screw

 

with

 

Nut

10

6

01111048

Connector

 

for

 

Pressure

 

Gauge

/

Stopper

1

7

89021303

Drain

 

Plug

 

with

 

O

'

Ring

1

8

06011029

Oil

 

Pressure

 

Gauge

 

With

 

O

-

ring

 (

40psi

)

1

9

02020016

O

-

Ring

 

for

 

2

.

0

"

Union

8

10

01013031

2

.

0

"

Connector

(

Black

)

3

11

01171154

2

.

0

"

Union

 (

A

/

E

)

3

12

01013032

2

.

0

"

Union

 

Nut

(

Black

)

3

13

02011009

O

-

Ring

 

for

 

2

.

0

Valve

 

Lid

1

14

01181002

Washer

 

for

 

spring

1

15

02011022

O

-

Ring

 

for

 

2

.

0

Valve

 

Rotor

2

16

03014014

Spring

1

17

01021002

2

.

0

Valve

 

Rotor

1

18

02311003

Spider

 

Gasket

1

19

01013026

2

.

0

Side

 

Mount

 

Valve

 

Bottom

 

Body

 (

Black

)

1

20

89280104

Sight

 

Glass

 

With

 

O

-

Ring

1

21

02011011

O

-

Ring

 

for

 

Union

 

Tale

1

22

01013099

2

.

0

Union

 

Tale

 (

Black

)

1

23

01013034

2

.

0

Union

 

Nut

 (

Black

)

2

24

02020017

O

-

Ring

 

for

 

Plug

1

25

01013101

2

.

0

Side

 

Mount

 

Valve

 

Plug

 (

Black

)

2

26

01013118

2

.

0

Elbow

 

Tube

 (

Black

)

183mm

1

27

01171035

2

.

0

Union

 

Adaptor

 (

Metric

)

1

MAIN DIMENSION

DIMENSION 

 

TABLE

B

A

3) 

 Tighten the Ring Lock Nut by 2 handles and make sure the nut is “sand free” on its thread. 

a) 

4) Connect pump to control valve opening marked PUMP.   
5) Make return to pool pipe connection to control valve opening marked RETURN and complete other 

necessary plumbing connections, suction lines to pump, waste, etc.

6) Make electrical connections to pump per pump instructions. 
7) To prevent water leakage, be sure all pipe connections are right.

Install the valve.

Carefully screw the T-shape Exhaust Switch onto the filter lid and make sure there do not over-tighten. 

b Ensure T-Shape Exhaust switch is tight fit to filter lid and turn it easily.

1) Be sure correct amount of filter media sand is in tank and that all connections have been made and are secure.
2) Depress control valve handle and rotate to BACKWASH position.   (To prevent damage to control valve seal, 

always depress handle before turning.)

3) Prime and start pump according to pump instructions (be sure all suction and return lines are open), allowing the 

filter tank to fill with water.  Once water is flowing out of the waste line, run the pump for at least 1 minute. The 
initial back-washing of the filter is recommended to remove any impurities or fine sand particles in the sand 
media.

4) Turn pump off and set valve to RINSE position.  Start pump and operate until water in sight glass is clear, about 1/2 

to 1 minute. Turn pump off and set valve to FILTER position and restart pump.The filter is now operating in the 
normal filter mode, filtering dirt particles from the pool water.

5) Adjust pool suction and return valves to achieve desired flow.   Check system and filter for water leaks and 

tighten connections, bolts, nuts, as required.

6) Note the initial pressure gauge reading when the filter is clean. (It will vary from pool to pool depending upon the 

pump  and  general  piping  system.)    As  the  filter  removes  dirt  and  impurities  from  the  pool  water,  the 
accumulation in the filter will cause the pressure to rise and flow to diminish.  When the pressure gauge reading is 
1.5 bar,  higher than the initial "clean" pressure you noted, it is time to backwash the filter (see BACKWASH under 
filter and control valve functions).

NOTE:  During initial clean-up of the pool water it may be necessary to backwash frequently due to the unusually 
heavy initial dirt load in the water.

INSTALL/START-UP OF FILTER

Key No.

Part No.

Description

Qty

1

01021004

Spanner for RingLock

1

2

01271013

2.0" Ringlock Nut

1

3

06011029

Oil Pressure Gauge With O-ring 

1

4

89014027

T-Shape Exhuaust Switch

1

5

01201020

Cover

1

6

02011036

O-Ring for Cover

1

7

89011212

S800 RINGLOCK Filter Tank With Base

1

7

89011213

S900 RINGLOCK Filter Tank With Base

1

8

89011203

The inner tank system for S700R(B)

1

8

89011210

 The inner tank system for S800( R)(B)

1

8

89011211

 The inner tank system for S900( R)(B)

1

9

01101065

2.0"Tank System Support

1

10

02020016

2.0" O-Ring for Connector

1

11

88280813B

6 Way 2" Valve with Piping Kit, 2" union 
set x 3 and pressure gauge (Black)

1

12*

01172010

Laterals (185mm) For S800R

8

12*

01172011

Laterals (233mm) For S900R

8

13

01112038

32-40 inch Filter Base

1

14

89010107

Water Drain set

1

Note:12* S800R should have 8pcs of Laterals (185mm)

     

12* S900R should have 8pcs of Laterals (233mm)

Отзывы: