P21 SPARE PART LIST
NT-UV40 & NT-UV75
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
1
2
1
1
2
2
1
2
4
2
2
2
2
2
2
1
2
1
1
1
1
1
1
E130423
111040015
E130426
E130427
440422251
111030021
103025325
E190201
620125430
620061857
111142482
430221017
111202472
1304565458
430170986
620145462
E130404
E130408
E130409
E130407
620135460
430170635
105021259
End Cap for Cable Hole With Epoxy
Lamp connector O'ring
40W UV lamp
75W UV lamp
25 Lamp adaptor
Quartz O'ring ( d24.8 x ф5.2 )
40W/75W Quartz tube D25 x 915mm
Pipe connection 2
"
Adaptor
25Cross
Connector O'ring
Transparent lid
UV body O'ring ( D76 x ф6 )
Body connection
Union Nut
Stainless steel body
Closed pipe clips
UV40 ballast
UV75 ballast
Earth Connection
Cap
Union Nut 1.5
"
Plug lead
Key No.
Part No.
Description
QTY
2
3
4
5
6
8
9 8 1011
12
13
14
15
1
7
16
17
19
20
16
17
1
18
21
20
INSTALLATION P6
4.2 DIMENSIONS
UV-16
353
353
122
580
UV40-T / UV75-T
UV40 / UV75
UV130-TF
UV130-F
UV87-TO
353
163
163
163
163
163
163
163
1012
1012
1012
1012
1012
1012
483
483
483
858
505
242
1040
483
Way 1
Way 2
Way 1
Way 2
5. INSTALLATION
Install the unit taking into consideration the access and space for servicing, and in a position where the lamp can
be taken out easily. It is important to choose your disinfection system according to the flow rate required for the
installation. If water passes through the unit too fast, the exposure time required for its maximum efficiency will
be not enough. For this reason, the ultraviolet equipment selected for your pool should correspond to the
maximum flow rate of your filtration system (pumps
)
.
We also recommend to install the unit in a by-pass.
5.1 PLUMBING INSTALLATION
WARNING:
It is recommended to use the same power source for UV-C system and the filtration pump
such that they can be power ON / OFF simultaneously to prevent no water flow for UV-C
lamp cooling inside the stainless steel cylinder.
This UV-C disinfection system comes with all internal components assembled and it is ready
to be installed. Only pipes connections should be made before starting up the equipment.