Specifications
Regulation
1 Before starting the water pump, ensure that the blow-down valve is
closed.
The water pump should be switched off when discharging filth.
If the filth in the filtration basket cannot be discharged through many
times of discharging, take out the filtration basket for cleaning.
)
2)
3)
2-2
B
C
F
ØD
E
N1
N2
ØA
Model
DIA
A (mm)
Length
B (mm)
Height
C (mm)
DIA
D (mm)
Length
E (mm)
Length
F (mm)
Inlet Flange
N1 GB(mm)
Outlet Flange
N2 GB(mm)
Flow Rate
(
m³/h
)
MER150-100S
565
965
981
440
310
593
150
100
123
MER200-150S
565
985
1113
440
354
705
200
150
192
MER250-200S
615
990
1260
490
468
837
250
200
301
MER300-200S
615
990
1260
490
468
837
300
200
447
6) If much filth is found in the filtration basket when inspected through
perspective mirror, switch off the water pump and the valves of water
inlet and outlet, open blow-down valve and discharge filth. after that,
close the blow-down valve, open the valves of water inlet and outlet
and then start the water pump again.