ICF  series  cartridge  filter  combines  superior  water  filtration  with  ease  of  operation  and  corrosion-free 

construction. With filtration ratings of 5,100~ 8,910 gallons (19,305 ~ 33,700 liters) per hour, they are designed for 

continuous  or  intermittent  operation,  for  installation  above  or  below  the  pool  waterline,  for  fresh  or  saltwater 

swimming pools or spas. ICF series filters utilize multiple reusable, reinforced polyester filter cartridge elements to 

provide a high degree of water clarity and long filter cycles with minimum care.

Do  not  operate  the  filter  until  you  have  read  and  understand  clearly  all  the  operating 

instructions  and  warning  messages  for  all  equipment  that  is  a  part  of  the  pool  circulating 

system. The following instructions are intended as a guide for initially operating the filter in a 

general pool installation. Failure to follow all operating instructions and warning messages can 

result in property damage or severe personal injur y or death.

To reduce the risk of injur y, do not permit children to use this product unless they are closely 

super vised at all times.

Due to the potential risk that can be involved it is recommended that the 

pressure test be kept to the minimum time required by the local code. Do 

not allow people to work around the system when the circulation system is 

under pressure test. Post appropriate warning signs and establish a barrier 

around  the  pressurized  equipment.  If  the  equipment  is  located  in  an 

equipment room, lock the door and post a warning sign.

Never attempt to adjust any closures or lids or attempt to remove or tighten bolts when the system is pressurized. 

These  actions  can  cause  the  closure  to  separate  and  could  cause  severe  personal  injur y  or  death  if  they  were  to 

strike a person.

N e ve r  e xc e e d  t h e  m a x i m u m  o p e r a t i n g  p re s s u re  of  t h e  s y s te m 

components.  Exceeding  these  limits  could  result  in  a  component  failing 

under  pressure.  This  instantaneous  release  of  energy  can  cause  the 

closure to separate and could cause severe personal injur y or death if they 

were to strike a person.

HYPERTHERMIA

 

SPA  water  temperature  excess  38°C  (104°F)  may  be  injurious  to  health. 

 

Measure water temperature before entering SPA.

Hyperthermia occurs when the internal temperature of the body reaches a level several degrees above the normal 
body temperature of 98.6 °F (37 °C). The symptoms of hyperthermia include drowsiness, lethargy, and an increase 
in the internal temperature of the body.

7. SPARE PART LIST

QTY

QTY

Key No.

Part No.

Description

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

550178232

111040077

111040078

550178233

117038519

111040079

111000048

430138225

550058225

550188172

550188173

550188174

550188175

550188176

4109000749

E140402

550008229

550128230

430308158

430178159

111040071

430248177

Handle Air release valve 

O-ring d14.3×2.5

O-ring d6×3.5

Air Release valve

Pressure gauge 60psi , plastic casing

O-ring d50×5

O-ring D76 x d65.6 x 5

Handle upper body

Nut for Handle

ICF230 upper body

ICF330 upper body

ICF430 upper body

ICF530 upper body

ICF680 upper body

Air release vent 

Element holder upper

Element holder lower

Inlet adaptor

Union 2inch/2.5inch ANSI 

Union Nut  2" 90

O-ring D77Xd62X8

Outer thread connector

1

1

1

1

1

1

2

1

1

1

1

1

1

1

1

1

1

1

2

2

2

2

SPARE PART LIST    P12

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

Содержание ICF 230

Страница 1: ...USER MANUAL STRIVE FOR CLEAR WATER www emauxgroup com MULTI ELEMENT CARTRIDGE FILTER Installation and Operation Manual EMAUX WATER TECHNOLOGY CO LTD Models ICF 230 330 430 530 680 EMFI22032602 ...

Страница 2: ... 13 This Limited Warranty extends only to products purchased from Emaux authorized reseller This Limited Warranty does not extend to any product that has been damaged or rendered defective a as a result of accident misuse or abuse b as a result of natural disaster c by operation outside the usage parameters stated herein d by the use of parts not manufactured or sold by Emaux e by modification of ...

Страница 3: ...mediately e g closure pressure gauge valve s O rings etc 6 Be sure that the filter is properly mounted and positioned according to instructions provided 1 2 2 3 This filter must be installed by a licensed or certified electrician or a qualified pool serviceman in accordance with the Local Code and all applicable local codes and ordinances Improper installation could result in death or serious inju...

Страница 4: ...s or attempt to remove or tighten bolts when the system is pressurized These actions can cause the closure to separate and could cause severe personal injury or death if they were to strike a person Never exceed the maximum operating pressure of the system components Exceeding these limits could result in a component failing under pressure This instantaneous release of energy can cause the closure...

Страница 5: ...tions 4 Reassemble per FILTER RE ASSEMBLY INSTRUCTIONS 5 Be sure to leave the drain plug unattached during the winter season to avoid cracking the filter body 5 WINTERIZING FILTER 6 TROUBLE SHOOTING Low water Flow SHORT FILTER CYCLES POOL WATER REMAINS CLOUDY REMEDY 1 Check skimmer and pump strainer baskets for debris 2 Check for restrictions in intake and discharge lines 4 Clean Filter Cartridges...

Страница 6: ...e 8 Unlock direction Holder Pressure gauge Relief valve Pressure gauge Figure 9 O ring Relief stopper Flange stopper P5 INSTALLATION 2 INSTALLATION This product should be installed and serviced only by a qualified pool professional 1 The filter system should be installed on a level concrete slab or another rigid base Select a well drained and vented area one that does not flood when it rains Posit...

Страница 7: ...LTER Notice Do not use any petroleum solvents to clean filter components Do not lubricate sealing O ring If the O ring is damaged it must be replaced 4 4 3 BODY AND LOCKING RING REASSEMBLY 1 Place the Sealing O Ring on the lower filter body 2 Place the upper filter body on Sealing O Ring and lower filter base in a position that allows all operation and safety labels to be visible and the upper fil...

Страница 8: ... starting pressure with the new filter cartridge elements the filter cartridge elements should be replaced the next time the gauge arrow reaches the red zone 3 3 OPERATION 4 MAINTAINING YOUR FILTER This product should be installed and serviced only by a qualified pool professional Figure 4 MAINTAINING YOUR FILTER P8 1 Turn off all system circulation pumps and all electric power on the equipment pa...

Отзывы: