background image

 

Diagram 1

Fish pond

Filter

Pump

SAFETY:

   

1) This device produces harmful radiation. Direct contact could impair the eyes and skin. 

Only  check  the  operation  of  the  UV-C  lamp  through  the  transparent  components  of 
the unit.

2)  Always  comply  with  the  electricity  company's  regulations  with  regard  to  any 

permanent connection to the mains. If there is any doubt regarding the connection, 
consult  a  recognized  fitter  or  the  electricity  company.  Always  work  with  a  residual 
current-operated circuit-breaker.

3) The device must be switched off if water treatment agents or medication are used.
4)  Always  remove  the  plug  from  the  socket  before  carrying  out  any  maintenance  or 

repair  work  on  the  unit.  Never  insert  /  pull  the  plug  from  the  socket  when  you  are 
standing in water or if your hands are wet.

5) Never submerge this device in water.
6) Keep children away from this device and from the cable.
7)  The  cable  of  the  device  cannot  be  replaced.  The  complete  electrical  unit  must  be 

replaced if there is any damage to the power cable.

8)  Once  the  device  has  been  switched  off,  the  lamp  will  remain  hot  for  around  10 

minutes.

9) Do not use the device if any of the components are damaged (especially the quartz 

tube).

10) Remove the device if there is a rish of freezing during the winter months.
11)  This  product  can  only  be  used  according  to  the  guidelines  described  in  these 

instructions for use.

INSTALLATION

:

    

1 Test the input voltage before installation! The voltage must be within 220-230V±10% to 

ensure normal operation.

2) An area of approx. 1.5m must be available at the top of the device in order to be able 

replace the lamp smoothly without having to dismantle the complete device.

 

3)  Please  refer  to  diagram  1  for  the  system  installation;  the  actual  installation  may  vary 

from different situation.

 

4) The two stands for the device must be mounted on the floor or on the wall. 
5) It is recommended to install a valve at the water inlet and outlet for easy maintenance.
6)  Activate  the  pump  and  check  that  there  is  flow  and  no  leakage  at  the  screw  top.  If 

there is leakage, fasten the screw top and check if there is any damage at the sealing 
ring. Never use force! The quartz glass is very fragile.

1 This device produces harmful radiation; direct contact could impair the eyes and skin. 

Keep children away from this device and from the cable.

2) After the installation, activate the pump and check the water flow for 5 mins to ensure 

there is no leakage before operating the device.

3)  Insert  the  plug  of  the  UV-C  device  into  a  wall  socket  with  a  safety  ground.  Check 

whether  the  lamp  is  operating  via  transparent  outlet  of  the  unit.  (the  light  is  “On” 
when the device is in normal operation)

4)  Always  switch  off  water  supply  then  switch  off  the  power  supply  when  the  operation 

stops, to avoid unsterilized water contaminating the pool water.

5) When the device is in use, check the system if there is any leakage, fasten the loosen 

screw cap and lock nut. If the lamp is not working, shut the power supply, unscrew the 
screw  cap  and  pull  the  lamp  out  from  the  top  of  the  device,  carefully  remove  the 
lamp from the lamp holder and replace it with a new lamp. No need to dismantle the 
whole device.

OPERATION

   

MAINTENENCE:
   

1 Always switch off the power supply and water supply during maintenance.
2)  Always  switch  off  the  power  supply  and  water  supply  when  replacing  the  UV-C  lamp 

and Quartz tube.

3) After the maintenance/dismantle, it is recommended to clean the device. If there are 

algae on the quartz tube, clean it with a soft cloth.

4) When  replacing  the  quartz  tube  or  sealing  ring,  unscrew  the  screw  cap  and  carefully 

remove the lamp from the lamp holder then replace the quartz tube. For safety reason, 
it  is  recommended  to  replace  the  quartz  tube  by  two  qualified  fitter  or  technician 
together.

5) The UV-C lamp must be replaced after 10,000 operating hours.

 

REMINDER:
  

 

1 Never frequently switch on/off the device in short period of time, or it will reduce the 

life span of the lamp.

2) Check the lamp only via the transparent outlet in order to protect the eyes.

PRODUCT DIMENSION:

A

Model No.

Product Dimension(mm)

  A

B

C

D

FOS-UV-5T/7T

694

431

180

166

FOS-UV-8T/14T

1144

881

180

166

B

D

C

3

2