background image

10.4 STUS SERIES

2

12

12

5

N

L

13

14

15

3

1

4

6

9

7

10

11

8

16

TERMS OF THE WARRANTY   P18

P17    REPLACEMENT PARTS

Key No.

Part Number

Description

QTY

1

2

3

4

5

6

6

7

8

9

10

11

12

12

13

13

14

15

16

89280105

02011104

03011213

01021046

02020041

01311015

01311016

04015033

01021024

89022104

02011156

89022101

04020056

04020070

04016040

04016040

89021505

01031027

01031010

1.5"union

O-Ring for 1.5" Union

M5*16 Screw for pump front

Pump body cover

O-Ring for pump body

Impeller SDUS050(110V/60HZ)

Impeller SDUS075(110V/60HZ)

1/2"Mechanical seal

ST SD Pump body 

M8*25 Screw with Washer for motor

Motor Slinger

Base with M5*20 Screw

Motor SDUS050(110V/60HZ)

Motor SDUS075(110V/60HZ)

Capacitor for SD050 Pump

Capacitor for SD075 Pump

Cable Box 

Cooling fan for SS/SD/SQ/ST050-SS/SD/SQ/ST120 Pump

Fan Cover for SQ/SP/SS/SD/ST050-SQ/SP/SS/SD/ST120

2

2

6

1

1

1

1

1

1

4

1

1

1

1

1

1

1

1

1

 

As  original  purchaser  of  this  equipment  have  purchased  from  Emaux  Water  Technology 

Co Ltd, through Authorized International Distributor or Dealer, warrants its products free 

from  defects  in  materials  and  workmanship  under  normal  use  during  warranty  period. 

The  warranty  period  begins  on  the  day  of  purchase  and  extends  only  to  the  original 

purchaser. It is not transferable to anyone who subsequently purchases the product from 

you. It excludes all expendable parts.

During  the  warranty  period,  Emaux  authorized  reseller  will  repair  or  replace  defective 

parts with new parts or, at the option of Emaux, ser viceable used parts that are equivalent 

or superior to new parts in performance.

This  Limited  Warranty  extends  only  to  products  purchased  from  Emaux  authorized 

reseller. This Limited Warranty does not extend to any product that has been damaged or 

rendered defective

(a) as a result of accident, misuse or abuse; 

(b) as a result of an act of God; 

(c) by operation outside the usage parameters stated herein; 

(d) by the use of parts not manufactured or sold by Emaux; 

(e) by modification of the product; 

(f) as a result of war or terrorist attack ; or 

(g)  as  a  result  of  ser vice  by  anyone  other  than  Emaux  authorized  reseller  or  authorized 

agent.

EXCEPT  AS  EXPRESSLY  SET  FORTH  IN  THIS  WARRANTY,  EMAUX  MAKES  NO  OTHER 

WARRANTIES  EXPRESSED  OR  IMPLIED,  INCLUDING  ANY  IMPLIED  WARRANTIES  OR 

MERCHANTABILITY  AND  FITNESS  FOR  A  PARTICULAR  PURPOSE.  EMAUX  EXPRESSLY 

DISCLAIMS  ALL  WARRANTIES  NOT  STATED  IN  THIS  LIMITED  WARRANTY.  ANY  IMPLIED 

WARRANTIES  THAT  MAY  BE  IMPOSED  BY  LAW  ARE  LIMITED  TO  THE  TERMS  OF  THIS 

EXPRESS LIMITED WARRANTY.

11. TERMS OF THE WARRANTY

Содержание 88020203

Страница 1: ...EMAUX WATER TECHNOLOGY CO LTD STRIVE FOR CLEAR WATER www emauxgroup com USER MANUAL Model SD ST Series SAA gepr fte Sicherheit SD SDUS Series ST STUS Series Swimming pool pump EMPU21070543...

Страница 2: ...he voltage should be referred to the individual pump operation voltage 6 The pump is capable of high flow rates use caution when installing and programming to limit pumps performance only 7 Switch OFF...

Страница 3: ...Baker VGB Pool and Spa Safety Act 1 Body Entrapment a section of the torso becomes entrapped 2 Limb Entrapment an arm or leg is caught by or pulled into an open drainpipe 3 Hair Entrapment or entangl...

Страница 4: ...8023203 88023204 88023205 88023206 Code 115V 60Hz 20 F 24 F 30 F 40 F 60 F 60 F 88020203 88020204 P5 PRODUCT INFORMATION ST STUS P6 88022101 88022102 88022103 88022104 88022105 88022106 Code 220V 50Hz...

Страница 5: ...rainage is adequate to prevent flooding 9 Make sure that the pump and piping are accessible for servicing Note The pump suction and discharge connections are mounded in thread stops DO NOT try to scre...

Страница 6: ...ody Clean and inspect the Lid s O ring ring reinstall on the Lid cover Clean the ring groove on the pre filter body and replace the Lid To help keep the Lid from sticking tighten it by hand only Put b...

Страница 7: ...or windings burned out 5 Defective starting switch inside single phase motor 6 Pump Shaft rotating in wrong direction 7 Low voltage Pump does not reach full speed 1 Low voltage 2 Pump connected to the...

Страница 8: ...or SS SD SQ ST033 Pump 100V Capacitor for SS SD SQ ST020 AMU020P TP 50 60Hz Capacitor for SS SD SQ ST033 Pump Cable Box for SD SQ SP ST050 120 Pump Cable Box for SQ ST SD020 033 SS020 SS030 Pump Cable...

Страница 9: ...on QTY 10 10 10 10 10 10 10 10 10 10 11 12 12 12 12 12 12 12 12 12 12 13 14 15 16 16 17 17 18 89022203 89022204 89022205 89022206 89022305 89022306 89022301 89022302 89022303 89022304 89022101 0401602...

Страница 10: ...egins on the day of purchase and extends only to the original purchaser It is not transferable to anyone who subsequently purchases the product from you It excludes all expendable parts During the war...

Отзывы: