(1) Group need to manual operation, contact usually use at uncertain factor or linkage with third 
party system  under emergency

 

(2) Group operation not include relay output, while contact include relay output, it is convenience 
to control third party to linkage 

 

 

Note

Please click “Application” after modify

or the modify is not successful.

 

1.3.1.3.3. System group configuration   

Click  “SYSTEM CONFIGURATION” then “Group”  as below

 

 

 

 
 

Description

 

1. “ID” is a system number

 

2. “NAME” this is name user, usually use a easy remember name so you can remember it easily. 

Such as below

system default is “GROUP 01...

,Click the item then enter modify mode

most 12 

character

press “Enter” to set next group

 

3. “WORK PARTITION” show zone list in current group, double click can add or delete sub item; 

 

① 

Left top of dialog box show current zone number

 

② 

Left part is current zone list, choose and add to the right means add the zone in current group, 

you can double click corresponding zone or though “Shift” and “Ctrl” button to continuous choose or 
discontinuous choose, also can add or delete though the middle operating button; 

③ 

  ">" and "<" as a single zone operation, ">" indicates that    add the system zone to the 

current group, "<" is a opposite operation, delete selected zone from the current group; 

4

"<<" and ">>" means deleting all zone and add all zone to the current group 

Содержание DVA6 Series

Страница 1: ...DVA6 240 DVA6 500 DVA6 240RT DVA6 500RT INSTALLATION AND OPERATION MANUAL...

Страница 2: ...cy Message 16 4 3 Auto Broadcast Emergency Message 16 4 4 Sosftware Setting 16 4 5 Emergency Fireman Microphone Operation 16 4 6 Remote Paging Microphone DVA8 500RM Operation 16 17 5 Software Introduc...

Страница 3: ...ually used in must small system which need voice evacuation or system that only need one call channel Features Meet the requirements of GB16806 2006 standard and European voice alarm control and Indic...

Страница 4: ...al amplifier wiring otherwise the host DVA6 500 will not auto standby to backup amplifier without software correct configuration 6 zone speaker outputs each zone max power output is 500W total 6 zone...

Страница 5: ...uts on the rear panel of host and extension unit and red light flashing Reset the Emergency Mode a Press the ACK Reset button on the front panel to exist the emergency mode to terminate the emergency...

Страница 6: ...the loop impedance value of the current speaker please follow below steps Unplug the host back row ID switch 7 Until hear buzzer sing alternately or see panel lights flashing after FAULT then Put the...

Страница 7: ...nuator Increase or decrease the built in monitor speaker loudness 21 Emergency Microphone Gain Control It is used to adjust the emergency microphone input sensitivity 22 Treble Control Increase or dec...

Страница 8: ...Outputs For 4 wired volume control each zone rated output current is 0 2A max total six zone outputs less than 28W 3 Six A B Speaker Zone Outputs Direct connection of 100V loudspeakers or 3 wire volum...

Страница 9: ...ware directly connection to DVA6 500 automatic identify cross and straight cable All communication cable shall be meet TIE EIA 568B standards including connection to extension and remote paging microp...

Страница 10: ...amplifier will be auto switched in service once the main amplifier have faulty the standby amplifier power shall be same watts or higher watts than the main amplifier The standby amplifier could be u...

Страница 11: ...er line supervision function 16 External Two Microphone or Balanced Line Inputs 5 6 17 Gain Control These gain control is used to increase or decrease the input sensitivity for MIC Line inputs 5 6 18...

Страница 12: ...Closed circuit no voltage EVAC State Output Closed circuit no voltage EVAC Reset Input Closed circuit no voltage T 0 5s 8 Program Control Output Closed circuit no voltage 8 Program Control Input Way 1...

Страница 13: ...paging microphone will be real time monitored by the system Feature Easy intuitive and user friendly operation paging console Configurable PPT paging mode and normal paging mode With 9 levels of confi...

Страница 14: ...ther to terminate the zone paging or add the zone paging 5 All Zone Selector Select or deselect all zones and the indicator will be illuminated or extinguished accordingly Button program to include so...

Страница 15: ...paging mic ID from No 1 to No 4 1 5 Technical Specification Model DVA8 500RM Description Remote Paging Microphone System Capacity 32 units Communication Distance 600 meters System Connection Star con...

Страница 16: ...xtension DVA6 500RT 2 Remote Paging Microphone DVA8 500RM 32 Software 1 Background Music Broadcast Input the audio sources or microphone to the line input1 6 on rear panel select the line input throug...

Страница 17: ...of control inputs by short circuit contact or by level mode Press again the emergency button or remote reset input to terminate the emergency broadcast Emergency Microphone Announcement Press the cli...

Страница 18: ...17 32...

Страница 19: ...one is prohibited for operation Current Zone is working Zone impedance vibration open circuit or short circuit The current zone is normal no broadcast The current zone is under emergency broadcast The...

Страница 20: ...are install or will have trouble after it Before that please check you have administration authority or not and the method as below Click on the icon EVAC exe by right mouse to select the properties t...

Страница 21: ...operation page of the software Click on to enter user name password for identity verification The software will be auto exist once 3 times wrong password input Synchronize The first connection of sof...

Страница 22: ...checking the working status of system s device module 2 SYSTEM CONFIGURATION for check or modify the working device data in current system 3 LOG is for checking data record of system device and modul...

Страница 23: ...or delete more zone of host or extension host After modify please make sure to click Application after modify The red LED on the top right can only reset via the red EMERGENCY button on the front pane...

Страница 24: ...INEINPUT AUDIO audio on the right side All system zones control for sure it will be the same result if you put all the system zones to one group or multi groups Choose the target zone Click all zones...

Страница 25: ...words system detects the impendence is more than 10 30 of the speaker first time system building base on can not designate error to single device or designated zone or cable is disconnect between dev...

Страница 26: ...as below You can use drop down list box which at the right of Host number 1 20 to set the number of host and extension host number System must set one host if host number is more than one and v button...

Страница 27: ...n click OK or the modify is not successful User can use Paging prompt tone switch to set the switch and designate warning tone of each microphone the way is the same as EVAC microphone above You can s...

Страница 28: ...ase note when you set Audio priority All zone means once get fire signal from host or extension host s Trigger Inputs then close all zone output and play EVAC voice message User can set delay time of...

Страница 29: ...below system default is GROUP 01 Click the item then enter modify mode most 12 character press Enter to set next group 3 WORK PARTITION show zone list in current group double click can add or delete...

Страница 30: ...lly added by system AUDIO NAME is the audio in the host PRIORITY means audio s priority but it also directly affect of the output permission of current audio please be careful when modifying the above...

Страница 31: ...ETAILED Means details of current log Description User can check designated time recording though Log type and and click on tooling bar to save the log as excel sheet 1 3 1 5 OTHER 1 Change password 2...

Страница 32: ...plication otherwise your settings can not be completed 3 Speaker zone impedance error adjustment Click EVAC system timing Select allowed error range of current speaker circuit from the drop down list...

Страница 33: ...ndicating not working correctly please shorten the wire actual measurement Cat5 can normal working in 600M Pay attention to the whole length of ring not single equipment 600M 6 Have a backup for main...

Отзывы: