ACCESS LEVEL

 – Administrators can choose to lock all functions on the amplifier modules 

by entering the relevant password – please contact EM Acoustics for further details on this 
function. 

VERSION  INFO

  –  by  pressing  the  Edit  encoder  repeatedly,  the  unit  will  step  through 

user  information  such  as  software  version,  hardware  version,  IP  address  and  MAC 
address. 

4.3.3 – EXIT Key 

The exit key takes you one step back in the menu system from wherever you are for each 
press of the key.  For example, if you have just adjusted the input gain, pressing the exit 
key will take you back to the parameter scroll screen. 

4.3.4 - EDIT encoder function 

The Edit encoder is the primary control for the user when operating the MSE-218SP.  From 
the  opening  display  screen  (which  displays  the  unit  name  –  which  by  default  is  “MSE-
218SP” but can be changed by the user in the remote software – on the top line and the 
loaded preset on the bottom line), simply rotating the encoder will display the unit status 
in the following order: 

INPUT GAIN=>INPUT DELAY=>INPUT SOURCE 

Pressing the edit encoder will then allow the user to edit the selected function: 

INPUT  GAIN

  –  adjustable  by  the  user  from  0dB  down  to  -20dB.    This  control  adjusts 

both analog and digital input gains simultaneously. 

INPUT DELAY

 – adjustable by the user from 0.0ms to 1000ms. 

INPUT SOURCE

 – this selects either standard analog input, or AES/EBU digital input.  If 

digital  is  selected,  the  yellow  “AES/EBU”  LED  will  illuminate  between  the  two  XLR 
connectors.    There  are  four  options  –  Analog,  AES/EBU  Left  channel,  AES/EBU  Right 
channel and AES/EBU mono sum. 

4.4 – Remote Monitoring and Control 

By  connecting  a  cat5  Ethernet  cable  to  the  RJ45  port  on  the  rear  of  the  unit,  remote 
monitoring and control can be achieved through the optional remote software.  Please see 
the  remote  software  manual  for  more  details.    The  amber  “Data”  LED  will  illuminate 
showing an active data connection. 

 

 

Содержание MSE-218SP

Страница 1: ...oustics Loudspeakers Building 74 Dunsfold Park Cranleigh Surrey GU6 8TB UK Phone 44 0 1483 266520 Fax 44 0 1483 275619 www emacoustics co uk ___________________________________________________________...

Страница 2: ...Page 9 3 5 Powering Up Page 10 Electrical Safety Issues Page 10 4 0 Amplification and Audio Page 11 4 1 Audio Inputs Page 11 4 2 Linking Audio Signals Page 12 4 3 DSP Menu Structure Page 12 4 4 Remote...

Страница 3: ...se harmful interference 2 This device must accept any interference received including interference that may cause undesired operation RECYCLING This product and its packaging constitute the applicable...

Страница 4: ...remain freely accessible at all times Unplug the loudspeaker from the mains power supply during electrical storms or when unused for long periods of time Disconnect the mains plug before disconnectin...

Страница 5: ...power line surges Disconnection from the mains power supply can only be achieved by removing the plug from the mains socket and by external disconnection of all poles from the mains INTERFERENCE OF E...

Страница 6: ...ORTANT When disconnecting this product from mains power always disconnect the mains end first before disconnecting the PowerCON connector Similarly when connecting this product always connect to the l...

Страница 7: ...d you should be congratulated for purchasing one of the finest loudspeaker products on the market today This manual contains all the information you should need on topics of set up connection flying s...

Страница 8: ...and touring applications The reflex design utilizes a pair of powerful 4 5 voice coil 18 457mm neodymium LF drive units in an incredibly rigid and rugged enclosure Various features have been incorpora...

Страница 9: ...or and as such you must ensure the total load does not exceed 20 amps 3 3 AC Link Connector GREY The grey Neutrik PowerCON connector supplies mains power to additional loudspeakers in the chain The Po...

Страница 10: ...lifier to detect a fault and require resetting Electrical Safety Issues Please pay close attention to the following electrical and safety issues a The MSE 218SP requires a grounded mains outlet Always...

Страница 11: ...one module per drive unit providing ample power to drive your loudspeakers to their full potential The amplifier and DSP combination also provides full limiting and remote monitoring 4 1 Audio Inputs...

Страница 12: ...name on the top line and the currently selected program on the bottom line Adjusting parameters via the MENU key or EDIT encoder will change the display to reflect the current function The output sig...

Страница 13: ...anged by the user in the remote software on the top line and the loaded preset on the bottom line simply rotating the encoder will display the unit status in the following order INPUT GAIN INPUT DELAY...

Страница 14: ...rds a cardoid subwoofer array can be created which offers significant low frequency rejection to the rear and sides of the array When using the MSE 218 in this way the two front firing subwoofers shou...

Страница 15: ...ase follow the guidelines below MSE 218 Low Frequency Drive Unit 1 Using a PZ2 Pozidrive screwdriver undo the screws securing the front grille in place Gently remove the grille from the front of the e...

Страница 16: ...8 4 kg lbs ENCLOSURE 18mm 3 4 multi laminate Birch plywood rebated screwed glued Finished in black semi matt textured paint RIGGING SUSPENSION 2 x M20 threaded flange adapters 8 x tour grade bar handl...

Страница 17: ...120V AC 200 240V AC 50 60Hz NOMINAL CURRENT 4 8A RMS 230V 9 6A RMS 120V POWER COMSUMPTION 822W nominal 4800W maximum Notes on measurement conditions 1 Measured on axis at 2m in an anechoic environmen...

Страница 18: ...1 1 February 2013 Appendix B Accessories Spare Parts List 01A022 DU 1802 18 neodymium LF drive unit 4 ohms 01C019 RK 1802 4 ohm recone kit for DU 1802 04A024 RG 218 Replacement steel grille 10E217 TC...

Страница 19: ...on any misrepresentation by the seller Products which contain anything other than the original components or EM Acoustics factory supplied spare parts Products on which the serial number has been rem...

Страница 20: ...ive components and as such are not liable for any incidental and consequential damages including without limitation injury to persons damage to property or loss of use This warranty is exclusive and n...

Отзывы: