EM-Technik GmbH - Industriestraße 2 - 67133 Maxdorf - Germany
[email protected]
www.em-technik.com
6
Error
Possible Cause
Error
Recti
fi
cation
Flexible tube
connection is leaking
Flexible tube is not
correct mounted
Mount connector
correctly, see 4.5
No
fl
ow
Connector is blocked Clean the connec-
tor or replace it if
necessary
10 Manufacturer‘s Declaration
• Our products do not fall under the scope of the Ma-
chinery Directive 2006/42/EC. However, they can be
incorporated in an installation that is considered as
machinery. In this case regard the following note: The
products may not be put into operation until it is made
sure that the
fi
nal machinery into which our products
are incorporated complies with the provisions of the
Machinery Directive 2006/42/EC.
• Based on the
fl
uid class, pressure and nominal diame-
ter, our products fall under diagram 8 of the Pressure
Equipment Directive PED 2014/68/EU. Because of the
ratio of nominal diameter, pressure and volume, they
fall only under article 4 paragraph 3 and are designed
and manufactured according to applicable good engi-
neering practice. They must not carry any CE marking.
• The warranty of armature expires in the following ca-
ses: Operating conditions which do not follow the in-
tended use or do not follow technical speci
fi
cations.
Improper installation or assembly. Just as well as inap-
propriate use, dismantling or modi
fi
cation.
• Failure to observe information provided here may lead
to injuries, material damage, malfunctions and impuri-
ties due to escaping medium.
11 Contact
If you have questions or suggestions please contact us at:
EM-Technik GmbH
Industriestr. 2
Tel +49 6237 407-0
67133 Maxdorf
Fax +49 6237 407-77
Germany
V