4

2 Manufacturer’s Specifi cation

2.1 Description

•  The fl exible tube is pushed onto the barb by hand and 

the  tube  expands.  If  the  connection  is  to  be  secured 
against shear, torsional or longitudinal forces, the tube 
must be fi xed to the barb, e.g. with a pipe clamp.

2.2 Transport and Storage

•  The connector must be protected  against mechanical 

damage, moisture, dirt and dust. The storage tempera-
ture range is 10 – 40°C. 

•  Avoid UV radiation and direct sunlight.
•  Leave the connector in its original packaging to ensure 

the best possible protection.

•  Dispose of the packaging material according to dispo-

sal requirements/environmental protection regulations.

3 Technical Data

3.1 Dimensions

The exact dimensions of the connector can be found on 
our homepage under the following link: 
www.em-technik.com
Special sizes can be asked via [email protected]

3.2 Operating Medium

•  Gaseous and liquid media that do not negatively aff ect 

the  physical  and  chemical  properties  of  the  relevant 
housing and sealing material. 

•  If you have questions about resistance please contact 

em

technik.

•  For the maximum permitted operating pressure/tempe-

rature see the pressure guide.

3.3 Pressure Guide

As  the  temperature  rises,  the  eff ectiveness  of  the  con-
nector falls, as shown by this table.

Material

PP

PVDF

Pressure Stage

PN 10

PN 10

-40°C

75%

-20°C

100%

5°C

100%

100%

20°C

100%

100%

30°C

80%

80%

40°C

70%

70%

50°C

60%

60%

60°C

50%

50%

70°C

40%

45%

80°C

30%

40%

90°C

20%

35%

100°C

35%

110°C

30%

120°C

25%

130°C

25%

140°C

10%

4 Assembly and Operation

4.1 Assembly Instructions

•  Make certain the connector is suitable for the relevant 

application.  The  connector  must  be  suitable  for  the 
operating conditions  of  the  linesystem  (medium,  con-
centration,  temperature  and  pressure)  as  well  as  the 
relevant ambient conditions.

•  Check  the  connector  for  transport  damage  before  in-

stalling it. If the connector is damaged do not install it.

•  The  planner,  the  construction  company  or  operating 

company  are  responsible  for  the  positioning  and  ins-
tallation of the connector. Planning and installation er-
rors can adversely aff ect the reliable functionality of the 
connector and may represent a signifi cant potential for 
hazard.

•  After the connector is installed perform a tightness and 

function check.