9
EMS-61 User Manual
www.emacoustics.co.uk
Attachment of the YK-61v vertical flying yoke
Using the supplied M8 countersunk machine screws, align the mounting
holes in the yoke with the mounting points on the side of the enclosure.
Once the desired angle is set, tighten the knobs to lock the position in
place. The bracket allows for complete rotation of the loudspeaker if
required. The points on the top of the L-bracket can be used for
permanent installations or to secure a hook clamp.
Ensure that an M8 eyebolt is secured to the rear point on the EMS-61
enclosure to use as a secondary safety.
Attachment of the YK-61h horizontal flying yoke
Using the supplied M8 hand knobs, align the mounting holes in the
yoke with the mounting points on the ends of the enclosure. Once
the desired angle is set, tighten the knobs to lock the position in
place. The bracket allows for complete rotation of the loudspeaker
if required. The points on the top of the L-bracket can be used for
permanent installations or to secure a hook clamp.
Ensure that an M8 eyebolt is secured to the rear point on the EMS-
61 enclosure to use as a secondary safety.
Attachment of the PM-61 polemount adapter
Screw the PM-61 into the M8 threaded point on the bottom or top of the enclosure.
Once you have the PM-61 mounted on a loudspeaker stand, use the hand knob on
the PM-61 to tighten the PM-61 to the stand.