7
4.3. Performance data
PUROTAP®
compenso 2 compenso 12 compenso 25 compenso 50
Annual
requirement
< 250 l
< 2500 l
< 5000 l
< 10,000 l
Capacity
at 1° dH
2.5 m³
20 m³
40 m³
80 m³
Capacity
at 1° fH
4.5 m³
35 m³
70 m³
140 m³
Flow rate
2.5 l/min
10 l/min
20 l/min
20 l/min
Operating
pressure
< 4 bar
< 4 bar
< 4 bar
< 4 bar
Max. temp.
60 °C
60 °C
60 °C
60 °C
5. Operation
5.1. Connection
5.1.1. Use with heating system fill hose
1. Flush the cartridge
Open the valves. Connect a hose from the appliance to the drinking water
supply. Route a further hose from the connection on the combined meter
side to a bucket. Flush the cartridge with approx. 10 l of water.
2. Refill the heating system
Now remove the hose from the bucket and connect it to the heating
system. Fill the heating system.
3. Close valves and remove hoses
• Permanent connection via a heating system fill hose is not
permitted.
• Unsupervised use is not permitted.
• Where DIN EN 1717 applies (Germany), observe the regulations
regarding system separation.