elysator PUROTAP compenso 12 Скачать руководство пользователя страница 1

www.elysator.com

Installation

Function

Operation

Service

Operating instructions

PUROTAP® compenso

Содержание PUROTAP compenso 12

Страница 1: ...www elysator com Installation Function Operation Service Operating instructions PUROTAP compenso...

Страница 2: ......

Страница 3: ...cification 4 1 Device description 6 4 2 Dimensions 6 4 3 Performance data 7 5 Installation 5 1 Connection 7 5 2 Combined meter 9 6 Maintenance 6 1 Replacing the resin 11 6 2 Changing the combined mete...

Страница 4: ...4 1 Safety instructions Not drinking water Maximum 60 C Maximum 4 bar pressure 4 bar...

Страница 5: ...changer to provide deionised fully desalinated water softened water for systems of all sizes This method does not emit any chemical additives into the water The appliance operates without an external...

Страница 6: ...ced hose 8 Wall mounting bracket 4 Resin canister 9 Air vent 5 Drain valve 4 2 Dimensions PUROTAP compenso 2 compenso 12 compenso 25 compenso 50 Installed length 45 cm 80 cm 80 cm 80 cm Height 46 cm 7...

Страница 7: ...ll hose 1 Flush the cartridge Open the valves Connect a hose from the appliance to the drinking water supply Route a further hose from the connection on the combined meter side to a bucket Flush the c...

Страница 8: ...ter utilities regulations must stringently be observed e g system separation to DIN EN 1717 Close all taps and valves on the heating and drinking water networks after use Safety instructions If perman...

Страница 9: ...gramming the limit ensures that a warning is issued when the ion exchange resin is spent If the set limit is exceeded the backlight flashes red and an acoustic alarm sounds In addition the floating co...

Страница 10: ...h the optional power supply unit the combined meter does not automatically switch off and cannot be switched off manually If the combined meter has switched off automatically it will automatically res...

Страница 11: ...0 We recommend resetting the JOB to 0 after every resin change to enable estimating and comparing the residual capacity of the ion exchange resin The TOTAL litres cannot be reset to 0 6 Maintenance 6...

Страница 12: ...he newly added resin at the same time This makes centring the brass head much easier Connect the reinforced hoses reset the combined meter to 0 see chapter 5 2 6 2 Changing the batteries on the combin...

Страница 13: ...100811 Immersion pipe 100556 100967 100968 100739 Canister 100203 100201 100202 100204 8 Consumables PUROTAP compenso 2 compenso 12 compenso 25 compenso 50 HF 1 7 l highpower 100920 HF 12 5 l highpowe...

Страница 14: ...ical modifications reserved The current version can be found at www elysator com EN0721 14 9 Accessories PUROTAP compenso 2 compenso 12 compenso 25 compenso 50 LFM 20 mains unit plus connector 102280...

Страница 15: ...Service booklet Installer Date of installation Project Device no Sludge removal interval Maintenance interval Date Job Meter mA Company signature...