6
SL24.W
6 - Control panel programming:
6.1 - Preliminary operations
To function correctly, the control panel requires some minimum and essential settings. There are two:
- Setting the motor type.
In its default configuration, the control panel is not associated to any type of motor. The type of motor associated to the
control panel must be set.
- Gate travel calibration
The control panel must know some physical parameters of the gate in order to function correctly. The operation allowing
the control panel to know these physical gate parameters is called travel calibration. If this is not done, the control panel
may not perform slowdowns or detect obstacles correctly.
6.2 - Using the display
The control panel is programmed using the display and the navigation buttons on board or via Smartphone/Tablet (see
paragraph "Wi-Fi connection to Smartphone/Tablet"). The control panel settings are shown on the display and can be
edited using the menu navigation buttons as shown in the following table:
Buttons
Function
Pressure length
OK
Switching on the display
Sub-menu entry
Confirm value change and return to menu
Instantaneous
▲
Scroll up
Increase parameter value
Instantaneous
▼
Scroll down
Reduce parameter value
Instantaneous
ESC
Exit the menu
Cancel value change and return to menu
Switching off the display
Instantaneous
▲+▼
Resetting the card
3 s
▲+ OK
Opening control
1 s
▼+ OK
Closing control
1 s
ESC + OK
Display test (switches on each segment of the display and points individually in
sequence)
3 s
ESC + OK
When the board is switched on the Firmware updating mode starts
3 s
PP
Step-step control
Instantaneous
6.3 - Menu
The control panel programming is organised into menus and sub-menus used to access and edit the parameters and
logics of the control panel. The control panel is equipped with the following first-level menus:
All sub-menus are described in the following table
Menu
Description
MOT
Motor parameters setup
LRNT
Travel calibration procedure run menu
TRV
Travel parameter settings menu
OUT
Auxiliary output configuration menu
IN
Input configuration menu
LGC
Operating logic settings menu
RAD
Remote control management menu
STAT
Diagnostic and reporting menu
EXP
Expansion board management menu
LOAD
Default value restore menu
PASS
Protection level settings menu
EN