Страница 1: ...Installer manual SL24 W Control panel for sliding gates 24 Vdc ...
Страница 2: ... 2 Description of the terminal blocks 2 Power supply connection 3 Connecting accessories 3 Programming the control panel 6 Diagnostics 18 Updating firmware 19 Control panel behaviour when loading settings 19 Control panel connection from Smartphone Tablet 20 ...
Страница 3: ... supply voltage 24 V DC Maximum motor power 150 W Flashing light output 24 V DC 35 W max Accessories power supply 24 V DC 500 mA Receiver memory 4032 Elvox rolling codes Receiver frequency 433 MHz Remote controls code Rolling code or fixed Fuse F1 ATO line protection 15 A Fuse F2 Accessories protection 5x20 mm F 3 15A Operating temperature 10 to 50 C Ports MEM for memory module MEM W connection in...
Страница 4: ...Control common N O C1 Configurable control 1 C2 Configurable control 2 C3 Configurable control 3 C4 Configurable control 4 PS 99 Safety device common N C S1 Configurable safety device 1 S2 Configurable safety device 2 S3 Configurable safety device 3 S4 Configurable safety device 4 ANT ANT Aerial signal Aerial earth T2 T1 BAT F1 SEC VR3 F2 ANT ANT 21 22 0 1 1 2 10 11 0 99 31 32 C3 C4 99 S1 S2 S3 S4...
Страница 5: ...tricity refer to the image below 5 Connecting accessories 5 1 Key switch and control device 5 2 Key switch and control device 21 22 0 1 1 2 10 11 0 99 31 32 C3 C4 99 S1 S2 S3 S4 A1 A2 T2 T1 C1 C2 99 21 22 0 1 1 2 10 11 0 99 31 32 C3 99 S1 S2 S3 S4 A1 A2 C1 C2 99 C4 BAT PP F1 PROGRAM MENU USB ESC OK CNX1 CNX2 PT1 SEC VR3 T1 T2 FSC1 MOT PS AUX LSW ENC ACT SAF MEM CNP1 SL24 W DL1 RADIO F2 PWR DL3 DL4...
Страница 6: ...ensitive edge 99 S1 S2 S3 S4 SAF COM 24 V 24 V 24 V TEST S1 7 PTCH S2 8 PHT 0 1 1 2 PS COM 24 V 24 V S1 1 PHC S2 2 PH 99 S1 S2 S3 S4 SAF COM S1 4 BAR S2 5 8k2 99 S1 S2 S3 S4 SAF COM S1 6 STP N C 8K2 8 2 KΩ 99 S1 S2 S3 S4 SAF COM S1 4 BAR S2 5 8k2 99 S1 S2 S3 S4 SAF COM S1 6 STP N C 8K2 8 2 KΩ EN ...
Страница 7: ...m presence signal involves 2 gates operating according to the following method gate 1 opens only if gate 2 is closed gate 2 opens only if gate 1 is closed gate 1 opens only if there is a presence signal gate 2 opens only if there is a presence signal When this mode is on the safety input S4 is automatically configured without the installer selecting it as an interlock input checks the state of clo...
Страница 8: ... on the display Sub menu entry Confirm value change and return to menu Instantaneous Scroll up Increase parameter value Instantaneous Scroll down Reduce parameter value Instantaneous ESC Exit the menu Cancel value change and return to menu Switching off the display Instantaneous Resetting the card 3 s OK Opening control 1 s OK Closing control 1 s ESC OK Display test switches on each segment of the...
Страница 9: ... speed set until it detects the mechanical stop LRNT Gate travel calibration LRNE Rapid travel calibration The calibration is done fully automatically and sets The slowdown in opening at 20 of the total travel The slowdown in closing at 20 of the total travel Pedestrian opening at 30 of the total travel Pressing button Msg on display Phase description PP Wait for start of calibration procedure PP ...
Страница 10: ...acle is detected when the current threshold or the encoder slowdown threshold is exceeded 2 Leaf stopped the obstacle is detected only when the leaf slows down excessively 3 Overcurrent the obstacle is detected when the current threshold is exceeded 4 Overcurrent and leaf stopped the obstacle is detected when the current threshold and the encoder slowdown threshold are exceeded at the same time T8...
Страница 11: ...speed 100 maximum speed T30 Motor slowdown speed when closing Default 30 1 minimum speed 100 maximum speed T32 Motor slowdown distance when opening of travel or total work time done at slowdown speed Default 20 0 No slowdown 100 Slowdown for the whole distance T34 Motor slowdown distance when closing of travel or total work time done at slowdown speed Default 20 0 No slowdown 100 Slowdown for the ...
Страница 12: ...ate left open OAB On if the gate remains open for a time longer than that defined by the open gate alarm logic L16 6 Maintenance MAN Output off when the number of maintenance signalling manoeuvres MNPS is reached in the diagnostics section 7 Synchronization output compass type interlock INB Automatically configures input S4 as synchronization input without any choice by the user The control panel ...
Страница 13: ...opening closes the gate in closing stops or opens the gate according to the step step logic setting L10 with the gate stopped after closing opens the gate Default C1 2 Pedestrian PED Opens the gate to the pedestrian position It acts like a step step if the command is given with the gate beyond the pedestri an position Default C2 3 Open OPEN The open command with the gate stopped and closed opens t...
Страница 14: ...gate to open in opening recloses it completely with the gate open allows it to close and does not reset the pause time in closing does not intervene 4 Sensitive edge with NC clean contact BAR with the gate stopped does not allow the gate to open in opening disengages with the gate open does not allow it to close and when released will reset the pause time in closing disengages 5 8 2 KΩ balanced se...
Страница 15: ... pause 3 Ignores closing and stop commands in opening in pause and in closing L6 Rapid closing Default OFF OFF Rapid closing function off 1 Rapid closing in gate mode The control panel starts to count the clearance time L7 from when the closing photocell is released when the clearance time expires it closes again 2 Rapid closing in barrier mode The control panel starts to count the clearance time ...
Страница 16: ...step is given ON Automatic closing not disabled when a stop command from step step is given L12 Stop from stop Default ON OFF Automatic closing disabled when a stop command from stop is given ON Automatic closing not disabled when a stop command from stop is given L14 Operation in battery Default 1 1 Standard operation 2 Normal operation with flashing light disabled 3 After a re open command it st...
Страница 17: ...emory position oooo Waiting for code 5001 Remote control button 1 saved as close 7099 Remote control button 99 saved as Courtesy light on 030 Remote control button 30 not in memory Remote control not in memory RE Remote control programming Default 1 OFF Remote programming of remote controls off 1 Remote programming of remote controls on used to programme remote controls from a remote control alrea...
Страница 18: ...ays of activity of the control panel 584 Reading of the number of days of activity of the control panel In the case described above the control panel was active for 584 days PONC Number of control panel power ups counter 2547 Reading of the number of control panel power ups In the example shown above the control panel was powered up 2547 times it could indicate a poor quality mains electricity wit...
Страница 19: ...K EMEM Loading from memory card error e g no card PASS Control panel protection level settings Programming block not authorised Default OFF OFF No protection 1 Protection of menus MOT LRNT TRV OUT IN LGC STAT EXP LOAD 2 Protection of menu RAD 3 Protection from connection via smartphone it is not possible to connect to the control panel from a smartphone 4 Protection of menus MOT LRNT TRV OUT IN LG...
Страница 20: ...d RX Radio command received from saved remote control or from App NX Radio command received from unsaved remote control button RD Rolling fixed code decoding off OAB Gate left open AT Gate in self calibration EN 7 2 Alarms Alarms are generally indications on the display of operating failures which prevent the automation system from work ing They appear on the display when the associated event occu...
Страница 21: ... Installer settings Password Remote controls Firmware Updating Fixed counters No variation Resettable counters Motor parameters Gate travel data Installer settings Password Remote controls LOAD MEM loading from memory card Fixed counters No variation Resettable counters Motor parameters Importing data from a MEM W memory card Gate travel data Self calibration on first manoeuvre Installer settings ...
Страница 22: ...in the EMC W module instructions to establish the connection Using the Wi Gate app all the configurations which can be done using the control panel buttons can also be done from the Smartphone which however uses full descriptions to make the meaning of the parameters immediately understand able In addition to connection to the control panel for more immediate and easy configuration the Wi Gate app...
Страница 23: ...0 6 2 2007 EN 61000 6 3 2007 A11 2011 Further hereby declares that the product must not be put into service until the final machinery into which it is to be incorporated has been declared in conformity with the provisions of Directive 2006 42 EC where appropriate Declares that the relevant technical documentation is compiled by Vimar SpA and in accordance with part B of Annex VII of Directive 2006...