AIR EXIT INSTALLATION
ASSEMBLY OF SHEET METAL FLUES
1. Ø150/120 mm Flue Adapter
2. 2x 3.5x9.5 Screw
3. Ø120/150mm Plastic Flue
4. Body
• Pull up to left the Internal Flue (1) using
screws (2) and screw it on the flue
connection sheet on the right and left (3)
(Fig. 13).
• Fix the exterior flue to the right and left
connection sheet at the rear side of the
hood body from the lower side using 2
screws (Fig. 13).
1. Internal Flue
2. Flue Connection Sheet Fitting Screws
3. Flue Connection Metallic Sheet
4. Flue Lower Fixing Screws
Internal and external sheet flues are inserted to
each other.
• Flue connection sheet 3 is held directly on
the wall under the cover by centering the
Hood or measured and marked at points E,
F.
• Drill points E and F with Ø6mm drill and
attach Ø6mm plastic pins. Attach flue
connection sheet with 3.9x22 screws.
Mount the plastic flue to the product body using
3.5x9.5 screws (Fig. 12).
• When required, attach the connection part
(1) on the plastic flue (3) and press firmly.
• Install air exhaust connection of the
appliance.
Fig. 12
Fig. 13
Models that feature self flue exhaust
do not feature Ø150 mm flue