background image

 

 

CMi6110 

User’s Manual English 

 

 

 

 

 

 

 

 

 

 

 

 

CMi6110 User’s Manual English 

page | 33 (42) 

[2022-10] 

 

v1.3 

 

 

 

 

Parameter 

Description 

Configurable 
values 

Default 
value 
(battery)  

Device access 

– 

Locked device & 
correct PAK 

or

 

open device

 

Device access 

– 

No PAK

 

Synchronize 
meter time 

Used in OTC via NFC 
to use time of mobile 
phone to synchronize 
meter clock 

Used via App 

N/A 

Writeable  

Readable 

UTC offset 

UTC offset of the 
meter (in minutes). 

-720 - 720 

Readable/ 
Writeable 

Readable 

Max meter 
retries 

Maximum amount of 
quick retries when 
failing communicating 
with a meter 

0-255 

255 

Readable/ 
Writeable 

Readable 

Factory reset 

Resets the CMi6110 
to factory settings 
(default setting for 
power mode is 
Active)  

N/A 

N/A 

Writeable 

N/A 

Table 8: Device Related Configurations 

 

LwM2M-related configurations available in CMi6110: 

Parameter 

Description 

Configurable 
values 

Default 
value 
(battery)  

Device access 

– 

Locked device & 
correct PAK 

or

 

open device

 

Device access 

– 

No PAK

 

Bootstrap IP 

IP address of the 
bootstrap server the 
module will connect 
to upon activation. 

N/A 

84.19.147.
226  
(Elvaco 
Bootstrap 
server) 

Readable/ 
Writeable 

Readable 

Bootstrap 
port 

Port of the bootstrap 
server the module will 
connect to upon 
activation. 

N/A 

5694 

Readable/ 
Writeable 

Readable 

Bootstrap 
security 

Sets the way data 
sent from the module 
is encrypted. 

DTLS / 
no security 

DTLS 

Readable/ 
Writeable 

Readable 

CoAP ack 
timeout 

LWM2M CoAP 
timeout value. 

See LWM2M 
specification for 
more info 

60 

Readable/ 
Writeable 

Readable 

CoAP max 
retransmit 

LWM2M max 
retransmit value. 

See LWM2M 
specification for 
more info 

Readable/ 
Writeable 

Readable 

DTLS min 
timeout 

The first timeout in 
seconds used when 
transmitting packets 
via DTLS for LWM2M 

 

60 

Readable/ 
Writeable 

Readable 

DTLS max 
timeout 

The last timeout in 
seconds used when 
transmitting packets 
via DTLS for LWM2M 

 

90 

Readable/ 
Writeable 

Readable 

Содержание CMi6110

Страница 1: ...CMi6110 User s Manual English CMi6110 User s Manual English V1 3...

Страница 2: ...5 3 2 Mounting battery power 10 5 3 3 Antenna connection 10 5 3 4 Start up and LED indications 11 5 3 5 Switch off reboot module 12 6 INTEGRATION GUIDE 13 6 1 PURPOSE 13 6 2 INTRODUCTION 13 6 3 STATUS...

Страница 3: ...Mi6110 User s Manual English CMi6110 User s Manual English page 3 42 2022 10 v1 3 10 DOCUMENT HISTORY 41 10 1 VERSIONS 41 11 REFERENCES 42 11 1 TERMS AND ABBREVIATIONS 42 11 2 NUMBER REPRESENTATION 42...

Страница 4: ...tion and product are provided on an as is basis only and may contain deficiencies or inadequacies Elvaco AB takes no responsibility for damages liabilities or other losses by using this product 1 1 Co...

Страница 5: ...energy while switched on Remember that interference can occur if the product is used close to TV sets radios computers or inadequately shielded equipment Follow any special regulations and always swi...

Страница 6: ...to find information in other languages please visit https www elvaco com 3 3 Symbols The following symbols are used throughout the manual to emphasize important information and useful tips The Note sy...

Страница 7: ...res of CMi6110 include IoT ready As soon as the meter connectivity module has been mounted and started up it will automatically initiate transmission of meter data without any manual steps needed The...

Страница 8: ...CMi6110 is compatible with any L G UH50 meter using software version 5 15 or later and L G UC50 calculators using software version 8 06 or higher CMi6110 can be supplied by using one of the following...

Страница 9: ...6110 After reading and carefully following each step of this chapter the MCM will be mounted and deployed Product specification CMi6110 5 2 Product overview CMi6110 Figure 1 CMi6110 frontside 1 Meter...

Страница 10: ...he Landis Gyr WZU NB IoT BAT battery holder in the right compartment Battery operation is available from FW 1 03 Models with earlier FW can be remotely updated The battery supplying the meter must be...

Страница 11: ...application Go to Apply mode set the power mode to active and press Apply settings Place the phone on the right side of the meter The mobile phone should vibrate three times This indicates that settin...

Страница 12: ...ch off reboot module To reboot the module press and hold the push button for 5 15 seconds Release the button when the green LED is lit To switch off the module press and hold the push button for 15 20...

Страница 13: ...r connect to the MQTT SN gateway and perform a DTLS handshake to generate the sessions keys used to encrypt the session key used to encrypt the meter data transport Each module has a security chip whe...

Страница 14: ...e Firmware Version 3 0 3 String Firmware version E Device Reboot 3 0 4 Reboot R Device Available Power Sources 3 0 6 0 Integer 0 7 Power source 1 Internal battery 2 External battery 6 AC Mains power R...

Страница 15: ...llular Connectivity Active Timer 10 0 5 Integer NB IoT T3324 R LwM2M Cellular Connectivity eDRX parameters for NB S1 mode 10 0 9 Opaque 8 bit NB IoT eDRX R LwM2M Cellular Connectivity Activated Profil...

Страница 16: ...33906 1 7 Integer Interval in minutes RW Elvaco MCM Config Meter Transmit Interval 33906 1 8 Integer Interval in minutes RW Elvaco MCM Config Meter Transmit Offset 33906 1 9 Integer Offset in minutes...

Страница 17: ...seconds RW Elvaco MCM Config Network Connection Maximum Hold off 33906 3 8 Integer Delay in seconds RW Elvaco MCM Config Network Search Period 33906 3 9 Integer Period in seconds RW Elvaco MCM Config...

Страница 18: ...5 2 Integer 0 1 Configuration value for power source Used when hardware unit cannot determine source 0 Battery 1 PSU RW Elvaco MCM Config NB IoT Radio Bands 33906 5 3 String NB IoT Radio Bands to use...

Страница 19: ...status Uptime 33907 0 Integer Uptime in seconds R Elvaco NB IoT status Average current consumption 33907 1 Integer Consumption in uA micro amps R Elvaco NB IoT status Network classification 33907 2 I...

Страница 20: ...4 F41 Meter battery empty 5 F5 Short circuit flow temperature sensor 6 F6 Short circuit return temperature sensor 7 F7 Fault in the internal memory CRC 8 F8 Error F1 F2 F5 or F6 pending for longer tha...

Страница 21: ...ST is in effect The timestamped meter data sent from the module can be adjusted to be sent in UTC by specifying the UTC offset configuration parameter The UTC offset will be subtracted from the timest...

Страница 22: ...tempted unsent data will be resent if possible Retransmission can be done by FIFO or LIFO Rules for retransmissions include maximum age of data order of data number of retransmitted data transmission...

Страница 23: ...ges according to it s transmit interval settings Meter read out is always related to meter s clock at time 00 00 00 Transmission time is randomized between read outs The user can customize the data se...

Страница 24: ...Tariff 2 Energy consumption kWh Mapped to OBIS 6 8 2 Tariff register 2 or heating energy in combined heat cooling meters Tariff 3 Energy consumption kWh Mapped to OBIS 6 8 3 Tariff register 3 Missing...

Страница 25: ...read by combining the year high and year low field For example year high 0010 and year low 010 year 0010010 0 standard time 1 daylight saving time 0 timestamp is valid 1 timestamp is not valid 2 Mete...

Страница 26: ...xxxx 0 1 C 025Fxxxx xxxx C 9 Error flags 5 bytes INT16 Error and warning flags 02FD17xxxx For further information about Error flags please refer to table 2 or the latest meter s manual 10 Tariff 1 En...

Страница 27: ...message 7 4 2 2 JSON The payload of message format JSON consists of one object with a list of key value pairs The names of each value type and unit is presented in Table 7 The values are encoded as nu...

Страница 28: ...estamps can be handled more efficiently SenML CBOR also provides one way to structure lists of readings in an efficient manner The first implementation will use M Bus for encoding the data transferred...

Страница 29: ...g more information than the remaining records in the pack This is to include more information for the first reading and then only a subset of values for the remaining records to save space SenML label...

Страница 30: ...e is 0 and encoder version is 0 Record Name field Data Comment 0 M Bus 0 0x0000 M Bus encoding of payload data Each data record contains all DIF VIF Values according to M Bus Note that M Bus uses LSB...

Страница 31: ...be several based on this SenML CBOR specification and the encoder version field above defines exactly which type and version is used The contents of the message are defined by the message format The...

Страница 32: ...ay is 4 containing 4x6 24 readings covering 2 days 7 5 Configuration options CMi6110 is configured via preconfigure service at delivery via LwM2M device management or via the Elvaco OTC App using NFC...

Страница 33: ...figurable values Default value battery Device access Locked device correct PAK or open device Device access No PAK Bootstrap IP IP address of the bootstrap server the module will connect to upon activ...

Страница 34: ...seconds between connection sequence attempts to LWM2M servers 1 86400 Readable Writeable Readable Sequence backoff Delay ranges in minutes to wait between full LWM2M sequence connection attempts I e I...

Страница 35: ...fore entering power saving mode 0 120 Readable Writeable Readable T3412 timer LTE Extended TAU timer This setting controls how long in seconds the modem will be in power saving mode before waking up 0...

Страница 36: ...it interval in seconds 1 30 Readable Writeable Readable Transmit delay Time period were the transmission while be randomized in minutes 1 240 Readable Writeable Readable Max uploads per transmission T...

Страница 37: ...able Readable Communicati on attempts MQTT SN max number of retries before considering operation failed 1 2 Readable Writeable Readable DTLS min timeout The first timeout in seconds used when transmit...

Страница 38: ...ectrical characteristics Nominal voltage PSU 3 0 4 2 VDC Nominal voltage Battery 2 4 3 4 VDC Power consumption max 400 mA Power consumption sleep mode 6 A Environmental specifications Operating temper...

Страница 39: ...v1 3 Configuration NFC via Elvaco OTC App via LwM2M Elvaco Evo DM system or third party DM system Preconfig on delivery General Supported Protocols LwM2M MQTT SN both over UDP Security DTLS 1 2 Data...

Страница 40: ...U EMC EN 301 489 1 V2 2 1 EMC EN 301 489 52 V1 1 2 EMC EN 55032 2015 EMC EN IEC 61000 3 2 2019 EMC EN 61000 3 3 2013 A1 EMC EN IEC 61000 3 11 2019 EMC EN 61000 3 12 2011 EMC EN 61000 4 2 2009 EMC EN I...

Страница 41: ...10 1 Versions Version Date Description V0 1 2021 02 Evaluation samples V1 0 2022 02 Rev 1B FW 2 0 0 2022 04 Added LWM2M 1 1 Send command information Chapter 6 2 V1 1 2022 07 Added write possibility f...

Страница 42: ...e MCM Meter Connectivity Module MD Meter Data MQTT MQ Telemetry Transport MQTT SN MQTT for Sensor Networks NB IoT Narrowband Internet of Things OSCORE Object Security Constrained RESTful Environments...

Отзывы: